An accurate setting for remapping process of foot plantar pressure

This paper present a precise and detailed study for the touch area on the foot based on amplifier gain settings of individual sensors that are distributed over the plantar insole area, the idea is to fill the insole area with sensor size areas that satisfy covering almost the foot touch area. The pr...

Full description

Bibliographic Details
Main Authors: Alwan, Omar Hussein, Wan Hassan, Wan Zuha, Che Soh, Azura, Jaafar, Haslina
Format: Article
Language:English
Published: American Scientific Publishers 2015
Online Access:http://psasir.upm.edu.my/id/eprint/43695/
http://psasir.upm.edu.my/id/eprint/43695/1/An%20accurate%20setting%20for%20remapping%20process%20of%20foot%20plantar%20pressure.pdf
_version_ 1848850297871400960
author Alwan, Omar Hussein
Wan Hassan, Wan Zuha
Che Soh, Azura
Jaafar, Haslina
author_facet Alwan, Omar Hussein
Wan Hassan, Wan Zuha
Che Soh, Azura
Jaafar, Haslina
author_sort Alwan, Omar Hussein
building UPM Institutional Repository
collection Online Access
description This paper present a precise and detailed study for the touch area on the foot based on amplifier gain settings of individual sensors that are distributed over the plantar insole area, the idea is to fill the insole area with sensor size areas that satisfy covering almost the foot touch area. The procedure includes steps have to be implemented to achieve accurate reference values with respect to body weight. The values of individual sensor points have been evaluated for the both (Foot-Sensor-Insole-Ground) and (Foot-Sensor-Ground). It is found that, there is a wide range difference between the test points in each case and the existence of the insole reduced the pressure weight. A percentage value according to total body weight can be being assigned as the reference points in future studies.
first_indexed 2025-11-15T10:04:03Z
format Article
id upm-43695
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T10:04:03Z
publishDate 2015
publisher American Scientific Publishers
recordtype eprints
repository_type Digital Repository
spelling upm-436952016-08-08T07:13:06Z http://psasir.upm.edu.my/id/eprint/43695/ An accurate setting for remapping process of foot plantar pressure Alwan, Omar Hussein Wan Hassan, Wan Zuha Che Soh, Azura Jaafar, Haslina This paper present a precise and detailed study for the touch area on the foot based on amplifier gain settings of individual sensors that are distributed over the plantar insole area, the idea is to fill the insole area with sensor size areas that satisfy covering almost the foot touch area. The procedure includes steps have to be implemented to achieve accurate reference values with respect to body weight. The values of individual sensor points have been evaluated for the both (Foot-Sensor-Insole-Ground) and (Foot-Sensor-Ground). It is found that, there is a wide range difference between the test points in each case and the existence of the insole reduced the pressure weight. A percentage value according to total body weight can be being assigned as the reference points in future studies. American Scientific Publishers 2015-10 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/43695/1/An%20accurate%20setting%20for%20remapping%20process%20of%20foot%20plantar%20pressure.pdf Alwan, Omar Hussein and Wan Hassan, Wan Zuha and Che Soh, Azura and Jaafar, Haslina (2015) An accurate setting for remapping process of foot plantar pressure. Advanced Science, Engineering and Medicine, 7 (10). pp. 872-876. ISSN 2164-6627; ESSN: 2164-6635 10.1166/asem.2015.1787
spellingShingle Alwan, Omar Hussein
Wan Hassan, Wan Zuha
Che Soh, Azura
Jaafar, Haslina
An accurate setting for remapping process of foot plantar pressure
title An accurate setting for remapping process of foot plantar pressure
title_full An accurate setting for remapping process of foot plantar pressure
title_fullStr An accurate setting for remapping process of foot plantar pressure
title_full_unstemmed An accurate setting for remapping process of foot plantar pressure
title_short An accurate setting for remapping process of foot plantar pressure
title_sort accurate setting for remapping process of foot plantar pressure
url http://psasir.upm.edu.my/id/eprint/43695/
http://psasir.upm.edu.my/id/eprint/43695/
http://psasir.upm.edu.my/id/eprint/43695/1/An%20accurate%20setting%20for%20remapping%20process%20of%20foot%20plantar%20pressure.pdf