A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection

In this study, a disposable screen-printed gold electrode (SPGE) utilized of silicon nanowires (SiNWs) and gold nanoparticles as sensing material was fabricated for detection of DNA oligomers related to dengue virus. Firstly, SiNWs/AuNPs-SPGE was developed by the dispersion of SiNWs in 3-Aminopropyl...

Full description

Bibliographic Details
Main Authors: Abd Rashid, Jahwarhar Izuan, Yusof, Nor Azah, Abdullah, Jaafar, Hashim, Uda, Hajian, Reza
Format: Article
Language:English
Published: IEEE 2015
Online Access:http://psasir.upm.edu.my/id/eprint/43536/
http://psasir.upm.edu.my/id/eprint/43536/1/abstract00.pdf
_version_ 1848850254912290816
author Abd Rashid, Jahwarhar Izuan
Yusof, Nor Azah
Abdullah, Jaafar
Hashim, Uda
Hajian, Reza
author_facet Abd Rashid, Jahwarhar Izuan
Yusof, Nor Azah
Abdullah, Jaafar
Hashim, Uda
Hajian, Reza
author_sort Abd Rashid, Jahwarhar Izuan
building UPM Institutional Repository
collection Online Access
description In this study, a disposable screen-printed gold electrode (SPGE) utilized of silicon nanowires (SiNWs) and gold nanoparticles as sensing material was fabricated for detection of DNA oligomers related to dengue virus. Firstly, SiNWs/AuNPs-SPGE was developed by the dispersion of SiNWs in 3-Aminopropyltriethoxysilane (APTES, 0.5 %) onto bare SPGE. Secondly, the AuNPs decoration on SiNWs-SPGE surface was functionalized using dithiopropionic acid (DTPA) through a self-assembly monolayer (SAM) technique. The electrochemical response of methylene blue (MB) as a redox indicator towards synthetic DNA oligomer after hybridization on SiNWs/AuNPs-SPGE was recorded by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The results demonstrated that the reduction peak current of MB was significantly decreased after DNA hybridization process. In addition, the developed biosensor showed a good storage stability and could achieve a linear range of 1.0 × 10-11-1.0 × 10-7 M (R= 0.98) with the detection limit of 1.63× 10-12 M.
first_indexed 2025-11-15T10:03:22Z
format Article
id upm-43536
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T10:03:22Z
publishDate 2015
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling upm-435362016-06-29T03:15:31Z http://psasir.upm.edu.my/id/eprint/43536/ A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection Abd Rashid, Jahwarhar Izuan Yusof, Nor Azah Abdullah, Jaafar Hashim, Uda Hajian, Reza In this study, a disposable screen-printed gold electrode (SPGE) utilized of silicon nanowires (SiNWs) and gold nanoparticles as sensing material was fabricated for detection of DNA oligomers related to dengue virus. Firstly, SiNWs/AuNPs-SPGE was developed by the dispersion of SiNWs in 3-Aminopropyltriethoxysilane (APTES, 0.5 %) onto bare SPGE. Secondly, the AuNPs decoration on SiNWs-SPGE surface was functionalized using dithiopropionic acid (DTPA) through a self-assembly monolayer (SAM) technique. The electrochemical response of methylene blue (MB) as a redox indicator towards synthetic DNA oligomer after hybridization on SiNWs/AuNPs-SPGE was recorded by cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques. The results demonstrated that the reduction peak current of MB was significantly decreased after DNA hybridization process. In addition, the developed biosensor showed a good storage stability and could achieve a linear range of 1.0 × 10-11-1.0 × 10-7 M (R= 0.98) with the detection limit of 1.63× 10-12 M. IEEE 2015-08 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/43536/1/abstract00.pdf Abd Rashid, Jahwarhar Izuan and Yusof, Nor Azah and Abdullah, Jaafar and Hashim, Uda and Hajian, Reza (2015) A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection. IEEE Sensors Journal, 15 (8). pp. 4420-4427. ISSN 1530-437X 10.1109/JSEN.2015.2417911
spellingShingle Abd Rashid, Jahwarhar Izuan
Yusof, Nor Azah
Abdullah, Jaafar
Hashim, Uda
Hajian, Reza
A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection
title A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection
title_full A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection
title_fullStr A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection
title_full_unstemmed A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection
title_short A novel disposable biosensor based on SiNWs/AuNPs modified-screen printed electrode for dengue virus DNA oligomer detection
title_sort novel disposable biosensor based on sinws/aunps modified-screen printed electrode for dengue virus dna oligomer detection
url http://psasir.upm.edu.my/id/eprint/43536/
http://psasir.upm.edu.my/id/eprint/43536/
http://psasir.upm.edu.my/id/eprint/43536/1/abstract00.pdf