Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
Present investigation aims to establish the dosimetric characteristics of a novel fabricated flat fibre TLD system for postal radiotherapy dose audits. Various thermoluminescence (TL) properties have been investigated for five sizes of 6 mol% Ge-doped optical fibres. Key dosimetric characteristics i...
| Main Authors: | Ahmad Fadzil, Muhammad Safwan, Ramli, N. N. H., Jusoh, M. A., Kadni, Taiman, Bradley, David A., Ung, Ngie Min, Hashim, Suhairul, Mohd Noor, Noramaliza |
|---|---|
| Format: | Conference or Workshop Item |
| Language: | English |
| Published: |
IOP Publishing
2014
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/43062/ http://psasir.upm.edu.my/id/eprint/43062/1/jpconf14_546_012010.pdf |
Similar Items
Investigation of thermoluminescene dosimetric characteristics of Ge-doped optical fibres and photonic crystal fibre for postal dosimetry audit of radiotherapy photon and electron beams.
by: Mohd. Noor, Noramaliza, et al.
by: Mohd. Noor, Noramaliza, et al.
Investigation of thermoluminescence dosimetry characteristics of ge-doped optical fibres and photonic cystal fibre for postal dosimetry audit of radiotherapy photon and electron beams
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
Treatment planning system dose verification for MLC-shaped photon beams in postal radiotherapy dosimetry audit: a single-centre pilot study
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2025)
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2025)
Use of fabricated germanium-doped optical fibres for radiotherapy postal dose audit of megavoltage photon beams under non-reference conditions in selected Malaysian radiotherapy facilities
by: Ahmad Fadzil, Muhammad Safwan
Published: (2020)
by: Ahmad Fadzil, Muhammad Safwan
Published: (2020)
Dosimetric characterisation of the nanodot optically stimulated luminescent dosimeter for use in national electron beam dosimetry audit services for radiotherapy facilities
by: Mohd Noor, Noramaliza, et al.
Published: (2024)
by: Mohd Noor, Noramaliza, et al.
Published: (2024)
Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
by: Abdullah, N., et al.
Published: (2022)
by: Abdullah, N., et al.
Published: (2022)
Stability of PRESAGE® dosimeter for end-to-end radiotherapy dosimetry audit and dose delivery
by: Mohyedin, Muhammad Zamir, et al.
Published: (2025)
by: Mohyedin, Muhammad Zamir, et al.
Published: (2025)
Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
by: M. Noor, Noramaliza, et al.
Published: (2017)
by: M. Noor, Noramaliza, et al.
Published: (2017)
Characterization of Ge-doped optical fibres for MV radiotherapy dosimetry
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
Dosimetric characteristics of fabricated ge-doped silica optical fibres for small field radiation dosimetry in radiotherapy
by: Lam, Siok Ee
Published: (2019)
by: Lam, Siok Ee
Published: (2019)
Diode Dosimetric
Characterisations And Assessments
For In-Vivo Dosimetry In
Radiotherapy Treatment
by: Marzuki, Rahmatfadli
Published: (2019)
by: Marzuki, Rahmatfadli
Published: (2019)
Dosimetric characteristics of fabricated Ge-doped silica optical fibre for small-field dosimetry
by: Lam, Siok Ee, et al.
Published: (2019)
by: Lam, Siok Ee, et al.
Published: (2019)
Radiotherapy dosimetry and the thermoluminescence characteristics of Ge-doped fibres of differing germanium dopant concentration and outer diameter
by: Mohd Noor, Noramaliza, et al.
Published: (2016)
by: Mohd Noor, Noramaliza, et al.
Published: (2016)
Characterization and correction of fading effects in GedofS microdosimeter for absorbed dose measurements
by: Mohd Noor, Noramaliza, et al.
Published: (2024)
by: Mohd Noor, Noramaliza, et al.
Published: (2024)
Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations
by: Moradi, F., et al.
Published: (2021)
by: Moradi, F., et al.
Published: (2021)
Characterization and correction of fading effects in GeDOFs microdosimeter for absorbed dose measurements
by: Noramaliza Mohd Noor,, et al.
Published: (2024)
by: Noramaliza Mohd Noor,, et al.
Published: (2024)
Dosimetry audit for megavoltage photon beams applied in non-reference conditions
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2022)
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2022)
Dose verification procedures in radiotherapy
by: Zakaria, Ahmad, et al.
Published: (1999)
by: Zakaria, Ahmad, et al.
Published: (1999)
Radiation dose homogeneity and critical organs in radiotherapy treatment of prostate cancer
by: Khairi, Y., et al.
Published: (2021)
by: Khairi, Y., et al.
Published: (2021)
Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)
by: Reduan Abdullah,, et al.
Published: (2015)
by: Reduan Abdullah,, et al.
Published: (2015)
Different germanium dopant concentration and the thermoluminescence characteristics of flat Ge-doped optical fibres
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2017)
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2017)
A systematic review: dosimetric characteristic of optically stimulated luminecence (osl) dosimeter with photon beam in radiotherapy
by: Zolkifli, Muhammad Firdaus
Published: (2020)
by: Zolkifli, Muhammad Firdaus
Published: (2020)
Dosimetric And Geometric Accuracy Of Image Guided Intensity Modulated Radiotherapy (IG-IMRT) In Head And Neck Cancer Patients
by: M Zamri, Nada' Alia
Published: (2019)
by: M Zamri, Nada' Alia
Published: (2019)
Time-temperature profiles effect on thermoluminescence glow curve formation of germanium doped optical fibres
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2022)
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2022)
Irradiated glass and thermoluminescence yield: Dosimetric utility reviewed
by: Bradley, D. A. *, et al.
Published: (2020)
by: Bradley, D. A. *, et al.
Published: (2020)
Iron oxide nanoparticles as radiobiological dose enhancer for radiotherapy
by: Lazim, Rosmazihana Mat
Published: (2016)
by: Lazim, Rosmazihana Mat
Published: (2016)
Post-Mastectomy Radiotherapy Involving Supraclavical Nodes – Matchline Dose, Tumour Dose And Organs At Risk Dose
by: Alzoubi, Ahmad Saleem Salem
Published: (2009)
by: Alzoubi, Ahmad Saleem Salem
Published: (2009)
Intelligent postal mails sorter
by: Omar, Mohd Arif Faiz, et al.
Published: (2011)
by: Omar, Mohd Arif Faiz, et al.
Published: (2011)
Photon irradiation response of photonic crystal fibres and flat fibres at radiation therapy doses
by: Hashim, Suhairul, et al.
Published: (2014)
by: Hashim, Suhairul, et al.
Published: (2014)
Independent tps dose verification for photon beam shaped with multileaf collimator: evidence from single-institution study
by: Ab Rahim, Rohaizah Mohamad, et al.
Published: (2023)
by: Ab Rahim, Rohaizah Mohamad, et al.
Published: (2023)
Dosimetric characterisation of silica fibre thermoluminescent sensors for medical and non medical applications / Farhad Moradi
by: Farhad , Moradi
Published: (2018)
by: Farhad , Moradi
Published: (2018)
Tailored Ge-doped fibres for passive electron radiotherapy dosimetry
by: Siti Nurasiah, M. N, et al.
Published: (2020)
by: Siti Nurasiah, M. N, et al.
Published: (2020)
A novel case-based reasoning approach to radiotherapy dose planning
by: Mishra, Nishikant
Published: (2012)
by: Mishra, Nishikant
Published: (2012)
Dosimetric characteristics of LKB:Cu,P solid TL detector
by: Hashim, S., et al.
Published: (2014)
by: Hashim, S., et al.
Published: (2014)
Characterization of amorphous thermoluminescence dosimeters for patient dose measurement in X-ray diagnostic procedures
by: Ramli, N. N. H., et al.
Published: (2015)
by: Ramli, N. N. H., et al.
Published: (2015)
Dosimetric utility of structural changes in gamma irradiated graphite-rich pencils
by: Sani, S.F. A., et al.
Published: (2020)
by: Sani, S.F. A., et al.
Published: (2020)
Dosimetric characteristics of a LKB:Cu,Mg solid thermoluminescence detector
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013)
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013)
Sun safety knowledge and practice in UK postal delivery workers
by: Houdmont, Jonathan, et al.
Published: (2016)
by: Houdmont, Jonathan, et al.
Published: (2016)
Ge-doped silica fibre proton beam measurements: thermoluminescence dose-response and glow curve characteristics
by: Hassan, M. F., et al.
Published: (2019)
by: Hassan, M. F., et al.
Published: (2019)
Raman study of lower toxicity polymer gel for radiotherapy dosimetry
by: Adenan, Mohd Zulfadli, et al.
Published: (2014)
by: Adenan, Mohd Zulfadli, et al.
Published: (2014)
Similar Items
-
Investigation of thermoluminescene dosimetric characteristics of Ge-doped optical fibres and photonic crystal fibre for postal dosimetry audit of radiotherapy photon and electron beams.
by: Mohd. Noor, Noramaliza, et al. -
Investigation of thermoluminescence dosimetry characteristics of ge-doped optical fibres and photonic cystal fibre for postal dosimetry audit of radiotherapy photon and electron beams
by: Mohd Noor, Noramaliza, et al.
Published: (2014) -
Treatment planning system dose verification for MLC-shaped photon beams in postal radiotherapy dosimetry audit: a single-centre pilot study
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2025) -
Use of fabricated germanium-doped optical fibres for radiotherapy postal dose audit of megavoltage photon beams under non-reference conditions in selected Malaysian radiotherapy facilities
by: Ahmad Fadzil, Muhammad Safwan
Published: (2020) -
Dosimetric characterisation of the nanodot optically stimulated luminescent dosimeter for use in national electron beam dosimetry audit services for radiotherapy facilities
by: Mohd Noor, Noramaliza, et al.
Published: (2024)