CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies
Most of the industrial chemical products encounter natural environmental risk in the process. The indoor release of hazardous dense gases is especial topic for discussion nowadays because the clouds of heavier gases have a tendency to stay near the ground level, causing fatal and injuries the people...
| Main Authors: | , , |
|---|---|
| Format: | Conference or Workshop Item |
| Language: | English |
| Published: |
IEEE
2014
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/39917/ http://psasir.upm.edu.my/id/eprint/39917/1/CFD%20analysis%20chlorine%20gas%20dispersion%20in%20indoor%20storage%20temperatures%20with%20wind%20velocities%20effect%20studies.pdf |
| _version_ | 1848849277776822272 |
|---|---|
| author | Safakar, Masiha Syam, Syafiie Yunus, Robiah |
| author_facet | Safakar, Masiha Syam, Syafiie Yunus, Robiah |
| author_sort | Safakar, Masiha |
| building | UPM Institutional Repository |
| collection | Online Access |
| description | Most of the industrial chemical products encounter natural environmental risk in the process. The indoor release of hazardous dense gases is especial topic for discussion nowadays because the clouds of heavier gases have a tendency to stay near the ground level, causing fatal and injuries the people. In this article a computational fluid dynamics (CFD) code FLUENT was employed in order to model the accidental indoor dispersion of chlorine from a small undetected leak in an indoor industrial space. The results of simulation represented that the chlorine gas spread would behave like liquid and flows on the floor, also the concentration of chlorine increased to above the ground level slowly. The effects of various temperatures and wind velocities on dispersion of heavier gas will help to better identify the potential risks. In this paper, the effects of the environmental situations with the release and spread of chlorine in the indoor space were meticulously examined. |
| first_indexed | 2025-11-15T09:47:51Z |
| format | Conference or Workshop Item |
| id | upm-39917 |
| institution | Universiti Putra Malaysia |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T09:47:51Z |
| publishDate | 2014 |
| publisher | IEEE |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | upm-399172017-06-06T09:15:35Z http://psasir.upm.edu.my/id/eprint/39917/ CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies Safakar, Masiha Syam, Syafiie Yunus, Robiah Most of the industrial chemical products encounter natural environmental risk in the process. The indoor release of hazardous dense gases is especial topic for discussion nowadays because the clouds of heavier gases have a tendency to stay near the ground level, causing fatal and injuries the people. In this article a computational fluid dynamics (CFD) code FLUENT was employed in order to model the accidental indoor dispersion of chlorine from a small undetected leak in an indoor industrial space. The results of simulation represented that the chlorine gas spread would behave like liquid and flows on the floor, also the concentration of chlorine increased to above the ground level slowly. The effects of various temperatures and wind velocities on dispersion of heavier gas will help to better identify the potential risks. In this paper, the effects of the environmental situations with the release and spread of chlorine in the indoor space were meticulously examined. IEEE 2014 Conference or Workshop Item NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/39917/1/CFD%20analysis%20chlorine%20gas%20dispersion%20in%20indoor%20storage%20temperatures%20with%20wind%20velocities%20effect%20studies.pdf Safakar, Masiha and Syam, Syafiie and Yunus, Robiah (2014) CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies. In: 2014 IEEE International Conference on Industrial Engineering and Engineering Management (IEEM), 9-12 Dec. 2014, Bandar Sunway, Selangor, Malaysia. (pp. 1219-1222). 10.1109/IEEM.2014.7058832 |
| spellingShingle | Safakar, Masiha Syam, Syafiie Yunus, Robiah CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies |
| title | CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies |
| title_full | CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies |
| title_fullStr | CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies |
| title_full_unstemmed | CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies |
| title_short | CFD analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies |
| title_sort | cfd analysis chlorine gas dispersion in indoor storage: temperatures with wind velocities effect studies |
| url | http://psasir.upm.edu.my/id/eprint/39917/ http://psasir.upm.edu.my/id/eprint/39917/ http://psasir.upm.edu.my/id/eprint/39917/1/CFD%20analysis%20chlorine%20gas%20dispersion%20in%20indoor%20storage%20temperatures%20with%20wind%20velocities%20effect%20studies.pdf |