In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method

Electrical bio-impedance measurement has great potential in many biomedical applications including vein graft surveillance. Studies have shown that thrombosis was the major cause of the vein graft failure. The meticulous skills of the surgeon and effective postoperative surveillance of vein graft re...

Full description

Bibliographic Details
Main Authors: Lee, Hoi Leong, Abu Bakar, Shahriman, Yaacob, Sazali, Mohamad Razlan, Zuradzman, Wan Ahmad, Wan Khairunizam, Ibrahim, Zunaidi, Cheng, Ee Meng, Zaaba, Siti Khadijah, Basah, Shafriza Nisha, Rojan, Mohd Afendi, Syed Waseem Ahmad, Sharifah Roohi
Format: Article
Language:English
Published: American-Eurasian Network for Scientific Information 2014
Online Access:http://psasir.upm.edu.my/id/eprint/38008/
http://psasir.upm.edu.my/id/eprint/38008/1/In%20vitro%20evaluation%20of%20finger%27s%20hemodynamics%20for%20vein%20graft%20surveillance%20using%20electrical%20bio-impedance%20method.pdf
_version_ 1848848759452073984
author Lee, Hoi Leong
Abu Bakar, Shahriman
Yaacob, Sazali
Mohamad Razlan, Zuradzman
Wan Ahmad, Wan Khairunizam
Ibrahim, Zunaidi
Cheng, Ee Meng
Zaaba, Siti Khadijah
Basah, Shafriza Nisha
Rojan, Mohd Afendi
Syed Waseem Ahmad, Sharifah Roohi
author_facet Lee, Hoi Leong
Abu Bakar, Shahriman
Yaacob, Sazali
Mohamad Razlan, Zuradzman
Wan Ahmad, Wan Khairunizam
Ibrahim, Zunaidi
Cheng, Ee Meng
Zaaba, Siti Khadijah
Basah, Shafriza Nisha
Rojan, Mohd Afendi
Syed Waseem Ahmad, Sharifah Roohi
author_sort Lee, Hoi Leong
building UPM Institutional Repository
collection Online Access
description Electrical bio-impedance measurement has great potential in many biomedical applications including vein graft surveillance. Studies have shown that thrombosis was the major cause of the vein graft failure. The meticulous skills of the surgeon and effective postoperative surveillance of vein graft remain the cornerstones of clinical success in the current surgical management of vein graft survival. Vascular blood flow is the key clinical indicators for the evaluation of patency of the vein graft and ensuring the patient's quality of life. In this work, electrical bio-impedance method has been proposed as an alternative to the existing surveillance method as it is non-invasive, portable, easy applicable in practice, fast response, radiation free, and required only low-cost instrumentation. It was employed to measure pulsatile changes in longitudinal bio-impedance to quantify arterial blood flow and blood volume. We expect that by measuring the changes in tissue bio-impedance which can be used to evaluate important peripheral hemodynamic, it allows the detection of early stage stenosis within vascular and vein graft as well as estimate its severity with predetermined normative data provided.
first_indexed 2025-11-15T09:39:36Z
format Article
id upm-38008
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T09:39:36Z
publishDate 2014
publisher American-Eurasian Network for Scientific Information
recordtype eprints
repository_type Digital Repository
spelling upm-380082019-06-28T00:51:10Z http://psasir.upm.edu.my/id/eprint/38008/ In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method Lee, Hoi Leong Abu Bakar, Shahriman Yaacob, Sazali Mohamad Razlan, Zuradzman Wan Ahmad, Wan Khairunizam Ibrahim, Zunaidi Cheng, Ee Meng Zaaba, Siti Khadijah Basah, Shafriza Nisha Rojan, Mohd Afendi Syed Waseem Ahmad, Sharifah Roohi Electrical bio-impedance measurement has great potential in many biomedical applications including vein graft surveillance. Studies have shown that thrombosis was the major cause of the vein graft failure. The meticulous skills of the surgeon and effective postoperative surveillance of vein graft remain the cornerstones of clinical success in the current surgical management of vein graft survival. Vascular blood flow is the key clinical indicators for the evaluation of patency of the vein graft and ensuring the patient's quality of life. In this work, electrical bio-impedance method has been proposed as an alternative to the existing surveillance method as it is non-invasive, portable, easy applicable in practice, fast response, radiation free, and required only low-cost instrumentation. It was employed to measure pulsatile changes in longitudinal bio-impedance to quantify arterial blood flow and blood volume. We expect that by measuring the changes in tissue bio-impedance which can be used to evaluate important peripheral hemodynamic, it allows the detection of early stage stenosis within vascular and vein graft as well as estimate its severity with predetermined normative data provided. American-Eurasian Network for Scientific Information 2014 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/38008/1/In%20vitro%20evaluation%20of%20finger%27s%20hemodynamics%20for%20vein%20graft%20surveillance%20using%20electrical%20bio-impedance%20method.pdf Lee, Hoi Leong and Abu Bakar, Shahriman and Yaacob, Sazali and Mohamad Razlan, Zuradzman and Wan Ahmad, Wan Khairunizam and Ibrahim, Zunaidi and Cheng, Ee Meng and Zaaba, Siti Khadijah and Basah, Shafriza Nisha and Rojan, Mohd Afendi and Syed Waseem Ahmad, Sharifah Roohi (2014) In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method. Australian Journal of Basic and Applied Sciences, 8 (spec.4). pp. 350-359. ISSN 1991-8178 http://ajbasweb.com/old/2-ajbas_Special_2014.html
spellingShingle Lee, Hoi Leong
Abu Bakar, Shahriman
Yaacob, Sazali
Mohamad Razlan, Zuradzman
Wan Ahmad, Wan Khairunizam
Ibrahim, Zunaidi
Cheng, Ee Meng
Zaaba, Siti Khadijah
Basah, Shafriza Nisha
Rojan, Mohd Afendi
Syed Waseem Ahmad, Sharifah Roohi
In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method
title In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method
title_full In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method
title_fullStr In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method
title_full_unstemmed In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method
title_short In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method
title_sort in vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method
url http://psasir.upm.edu.my/id/eprint/38008/
http://psasir.upm.edu.my/id/eprint/38008/
http://psasir.upm.edu.my/id/eprint/38008/1/In%20vitro%20evaluation%20of%20finger%27s%20hemodynamics%20for%20vein%20graft%20surveillance%20using%20electrical%20bio-impedance%20method.pdf