Dosimetric characteristics of LKB:Cu,P solid TL detector
The dosimetric characteristics of newly developed borate glass dosimeter modified with lithium and potassium carbonate (LKB) and co-doped with CuO and NH4H2PO4 are reported. Broad peaks in the absence of any sharp peak confirms the amorphous nature of the prepared glass. A simple glow curve of Cu do...
| Main Authors: | Hashim, S., Alajerami, Y. S. M., Ghoshal, S. K., Saleh, M. A., Saripan, M. I., Kadir, A. B. A., Bradley, D. A., Alzimami, K. |
|---|---|
| Format: | Article |
| Published: |
Elsevier
2014
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/37153/ |
Similar Items
Dosimetric characteristics of a LKB:Cu,Mg solid thermoluminescence detector
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013)
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013)
Response of LiF:Mg,Cu,P TL detector simulated with Geant4
by: Supian Samat,, et al.
Published: (2017)
by: Supian Samat,, et al.
Published: (2017)
Irradiated glass and thermoluminescence yield: Dosimetric utility reviewed
by: Bradley, D. A. *, et al.
Published: (2020)
by: Bradley, D. A. *, et al.
Published: (2020)
Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields
by: Fartaria, M., et al.
Published: (2016)
by: Fartaria, M., et al.
Published: (2016)
GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery
by: Alyahyawi, A., et al.
Published: (2021)
by: Alyahyawi, A., et al.
Published: (2021)
Dosimetric utility of structural changes in gamma irradiated graphite-rich pencils
by: Sani, S.F. A., et al.
Published: (2020)
by: Sani, S.F. A., et al.
Published: (2020)
Development of tailor-made silica fibres for TL dosimetry
by: Bradley, David Andrew, et al.
Published: (2014)
by: Bradley, David Andrew, et al.
Published: (2014)
Effect of particle size on the thermoluminescence (TL) response of silica nanoparticles
by: Ahmad Shaharuddin, Siti Shafiqah, et al.
Published: (2015)
by: Ahmad Shaharuddin, Siti Shafiqah, et al.
Published: (2015)
Thermoluminescence responses of photon- and electron-irradiated lithium potassium borate co-doped with Cu+Mg or Ti+Mg
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013)
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013)
Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2014)
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2014)
Investigation of silica-based TL media for diagnostic x-ray dosimetry
by: Amjad., Alyahyawi,, et al.
Published: (2017)
by: Amjad., Alyahyawi,, et al.
Published: (2017)
Dosimetric characteristics of fabricated Ge-doped silica optical fibre for small-field dosimetry
by: Lam, Siok Ee, et al.
Published: (2019)
by: Lam, Siok Ee, et al.
Published: (2019)
Enhance TL response due to radiation defects in Ge doped silica preforms
by: Ahmad Shaharuddin, Siti Shafiqah, et al.
Published: (2015)
by: Ahmad Shaharuddin, Siti Shafiqah, et al.
Published: (2015)
Dosimetric evaluation of gold nanoparticle aided intraoperative radiotherapy with the Intrabeam system using Monte Carlo simulations
by: Moradi, F., et al.
Published: (2021)
by: Moradi, F., et al.
Published: (2021)
Dosimetric characteristics of fabricated germanium doped optical fibres for a postal audit of therapy electron beams
by: Abdullah, N., et al.
Published: (2022)
by: Abdullah, N., et al.
Published: (2022)
The effect of TiO2 and MgO on the thermoluminescence properties of a lithium potassium borate glass system
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013)
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013)
Electrical properties and AC susceptibility of CdTe added
Tl2Ba2CaCu2O8-δ superconductor
by: K. Muhammad-Aizat,, et al.
Published: (2018)
by: K. Muhammad-Aizat,, et al.
Published: (2018)
Dopant concentration and thermoluminescence (TL) properties of tailor-made Ge-doped SiO2 fibres
by: Zahaimi, Nurul Arina, et al.
Published: (2014)
by: Zahaimi, Nurul Arina, et al.
Published: (2014)
SoTL Bulletin vol.1/2017
by: Universiti Malaysia Sarawak, Centre for Applied Learning and Multimedia
Published: (2017)
by: Universiti Malaysia Sarawak, Centre for Applied Learning and Multimedia
Published: (2017)
Anthropomorphic phantom organ dose assessment using optically stimulated luminescence dosimeters unified in multi-detector computed tomography
by: Omar, R.S., et al.
Published: (2022)
by: Omar, R.S., et al.
Published: (2022)
Measurement of Dosimetric Parameters and Dose Verification in Stereotactic Radiosurgery (SRS)
by: Reduan Abdullah,, et al.
Published: (2015)
by: Reduan Abdullah,, et al.
Published: (2015)
Diode Dosimetric
Characterisations And Assessments
For In-Vivo Dosimetry In
Radiotherapy Treatment
by: Marzuki, Rahmatfadli
Published: (2019)
by: Marzuki, Rahmatfadli
Published: (2019)
Thermoluminescence dosimetry properties and kinetic parameters of lithium potassium borate glass co-doped with titanium and magnesium oxides
by: Hashim, Suhairul, et al.
Published: (2014)
by: Hashim, Suhairul, et al.
Published: (2014)
Being chimaera: a monstrous identity for SoTL academics
by: Bennett, Rebecca, et al.
Published: (2015)
by: Bennett, Rebecca, et al.
Published: (2015)
Brochure Fellowship of Teaching and Learning Advancement (FoTL) (2017)
by: Universiti Malaysia Sarawak, Centre for Applied Learning and Multimedia
Published: (2017)
by: Universiti Malaysia Sarawak, Centre for Applied Learning and Multimedia
Published: (2017)
Small-field radiotherapy photon beam output evaluation: Detectors reviewed
by: Lam, S.E., et al.
Published: (2021)
by: Lam, S.E., et al.
Published: (2021)
Design of composite right/left-handed (CRLH) transmission line (TL) based leaky-wave array antenna
by: Wan Nordin, Mimi Aminah, et al.
Published: (2009)
by: Wan Nordin, Mimi Aminah, et al.
Published: (2009)
Dosimetric response of fabricated Ge-doped optical fibres in computed tomography RQT beam quality x-ray beams
by: Mohd Rais, Nur Nadiah, et al.
Published: (2019)
by: Mohd Rais, Nur Nadiah, et al.
Published: (2019)
Investigation of thermoluminescene dosimetric characteristics of Ge-doped optical fibres and photonic crystal fibre for postal dosimetry audit of radiotherapy photon and electron beams.
by: Mohd. Noor, Noramaliza, et al.
by: Mohd. Noor, Noramaliza, et al.
Pembentukan fasa dan suhu genting superkonduktor (Tl0.5Pb0.5)Sr2Ca(Cu2-xCrx)O7-δ(x = 0 - 0.100)
by: E. Yusrianto,, et al.
Published: (2021)
by: E. Yusrianto,, et al.
Published: (2021)
Pointing model of new Pi of the Sky detector in Spain.
by: Cwiok, M., et al.
Published: (2011)
by: Cwiok, M., et al.
Published: (2011)
Utilization of carbon nanotubes in electromagnetic wave detectors
by: N., Yahya, et al.
Published: (2009)
by: N., Yahya, et al.
Published: (2009)
A novel bandwidth enhancement technique for a compact right/left-handed (CRLH)transmission line (TL) based antenna
by: Wan Nordin, Mimi Aminah, et al.
Published: (2011)
by: Wan Nordin, Mimi Aminah, et al.
Published: (2011)
The prototype detection unit of the KM3NeT detector
by: Adrian-Martinez, S., et al.
Published: (2016)
by: Adrian-Martinez, S., et al.
Published: (2016)
Dosimetric And Geometric Accuracy Of Image Guided Intensity Modulated Radiotherapy (IG-IMRT) In Head And Neck Cancer Patients
by: M Zamri, Nada' Alia
Published: (2019)
by: M Zamri, Nada' Alia
Published: (2019)
Atenuasi ultrasonik dan modulus ricih pada suhu genting superkonduktor terdop sederhana (Tl0.8Bi0.2)Sr2 (Ca0.9Cr0.1)Cu2 O7
by: R. Abd-Shukor,, et al.
Published: (2022)
by: R. Abd-Shukor,, et al.
Published: (2022)
Evidence for high-energy extraterrestrial neutrinos at the icecube detector
by: Aartsen, M., et al.
Published: (2013)
by: Aartsen, M., et al.
Published: (2013)
Flood detector
by: Emi Rahayu, Mat Noor
Published: (2008)
by: Emi Rahayu, Mat Noor
Published: (2008)
Text detector
by: Ibrahim, Rahinah
Published: (2016)
by: Ibrahim, Rahinah
Published: (2016)
UV-VIS spectral evaluation of CR-39 detector exposed with diagnostic dosage
by: Nur Sha'dah, Z., et al.
Published: (2014)
by: Nur Sha'dah, Z., et al.
Published: (2014)
Similar Items
-
Dosimetric characteristics of a LKB:Cu,Mg solid thermoluminescence detector
by: Alajerami, Yasser Saleh Mustafa, et al.
Published: (2013) -
Response of LiF:Mg,Cu,P TL detector simulated with Geant4
by: Supian Samat,, et al.
Published: (2017) -
Irradiated glass and thermoluminescence yield: Dosimetric utility reviewed
by: Bradley, D. A. *, et al.
Published: (2020) -
Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields
by: Fartaria, M., et al.
Published: (2016) -
GeB flat fibre TL dosimeters for in-vivo measurements in radiosurgery
by: Alyahyawi, A., et al.
Published: (2021)