An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study

The Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective asses...

Full description

Bibliographic Details
Main Authors: Alsayed, Abdallah S. Z., Raja Ahmad, Raja Mohd Kamil, Harun @ Ramli, Hafiz Rashidi, As'arry, Azizan
Format: Article
Language:English
Published: MDPI 2020
Online Access:http://psasir.upm.edu.my/id/eprint/36695/
http://psasir.upm.edu.my/id/eprint/36695/1/36695.pdf
_version_ 1848848404296237056
author Alsayed, Abdallah S. Z.
Raja Ahmad, Raja Mohd Kamil
Harun @ Ramli, Hafiz Rashidi
As'arry, Azizan
author_facet Alsayed, Abdallah S. Z.
Raja Ahmad, Raja Mohd Kamil
Harun @ Ramli, Hafiz Rashidi
As'arry, Azizan
author_sort Alsayed, Abdallah S. Z.
building UPM Institutional Repository
collection Online Access
description The Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective assessment. In this study, an automated data acquisition system that consists of a linear electric actuator applying automatic pulling to the customized pincer object held by the volunteer was developed. The pinch force was measured such that a strain gauge was placed on the pincer object while pulling force was measured using pulling force load cell connected in between the linear electric actuator and customized pincer object. The pincer object’s slip onset was detected using a displacement slip sensor. The mean pinch and pulling force values at the slip onset were 12.17 and 6.25 N for right hands, while mean pinch and pulling force values were 11.67 and 5.92 N for left hands of 50 healthy volunteers, respectively. Based on the paired t-test, there is no significant difference between right and left hands. The automated data acquisition system can objectively apply a pulling force, detect the slip onset, and measure the pinch and pulling forces.
first_indexed 2025-11-15T09:33:58Z
format Article
id upm-36695
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T09:33:58Z
publishDate 2020
publisher MDPI
recordtype eprints
repository_type Digital Repository
spelling upm-366952020-06-16T01:24:23Z http://psasir.upm.edu.my/id/eprint/36695/ An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study Alsayed, Abdallah S. Z. Raja Ahmad, Raja Mohd Kamil Harun @ Ramli, Hafiz Rashidi As'arry, Azizan The Upper Extremity Fugl Meyer Assessment (UE-FMA) is the most comprehensive assessment for pinch impairment after stroke. The pinch test of UE-FMA is manually performed by pulling a pincer object away from the patient’s fingers while providing a visual observation that results in a subjective assessment. In this study, an automated data acquisition system that consists of a linear electric actuator applying automatic pulling to the customized pincer object held by the volunteer was developed. The pinch force was measured such that a strain gauge was placed on the pincer object while pulling force was measured using pulling force load cell connected in between the linear electric actuator and customized pincer object. The pincer object’s slip onset was detected using a displacement slip sensor. The mean pinch and pulling force values at the slip onset were 12.17 and 6.25 N for right hands, while mean pinch and pulling force values were 11.67 and 5.92 N for left hands of 50 healthy volunteers, respectively. Based on the paired t-test, there is no significant difference between right and left hands. The automated data acquisition system can objectively apply a pulling force, detect the slip onset, and measure the pinch and pulling forces. MDPI 2020 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/36695/1/36695.pdf Alsayed, Abdallah S. Z. and Raja Ahmad, Raja Mohd Kamil and Harun @ Ramli, Hafiz Rashidi and As'arry, Azizan (2020) An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study. Applied Sciences, 10 (10). art. no. 3436. pp. 1-18. ISSN 2076-3417 https://www.mdpi.com/2076-3417/10/10/3436 10.3390/app10103436
spellingShingle Alsayed, Abdallah S. Z.
Raja Ahmad, Raja Mohd Kamil
Harun @ Ramli, Hafiz Rashidi
As'arry, Azizan
An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study
title An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study
title_full An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study
title_fullStr An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study
title_full_unstemmed An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study
title_short An automated data acquisition system for pinch grip assessment based on Fugl Meyer protocol: a feasibility study
title_sort automated data acquisition system for pinch grip assessment based on fugl meyer protocol: a feasibility study
url http://psasir.upm.edu.my/id/eprint/36695/
http://psasir.upm.edu.my/id/eprint/36695/
http://psasir.upm.edu.my/id/eprint/36695/
http://psasir.upm.edu.my/id/eprint/36695/1/36695.pdf