Construction and use of a custom-made digital pressure threshold device in cats

A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure thr...

Full description

Bibliographic Details
Main Authors: Basiri, Bita, Chen, Hee Chong, Dehzangi, Arash
Format: Conference or Workshop Item
Language:English
Published: 2012
Online Access:http://psasir.upm.edu.my/id/eprint/32215/
http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf
_version_ 1848847155422298112
author Basiri, Bita
Chen, Hee Chong
Dehzangi, Arash
author_facet Basiri, Bita
Chen, Hee Chong
Dehzangi, Arash
author_sort Basiri, Bita
building UPM Institutional Repository
collection Online Access
description A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure threshold of the metatarsal pad in cats. This device was used to compare the pressure thresholds of tramadol hydrochloride at 4 mg/kg, SC, and acepromazine at 0.1 mg/kg, SC. Six cats were used in a randomized cross over design with two weeks wash out period. The results showed that tramadol increased the pressure thresholds at 3, 4, 5 and 6 hours post injection while acepromazine did not change the pressure thresholds significantly. This trial demonstrated that measurement of pressure thresholds at the metatarsal pad can be used to differentiate if a treatment had antinociceptive property. As the device is portable and easily operated, it would be a useful tool to study analgesics and their efficacies in clinical setting.
first_indexed 2025-11-15T09:14:07Z
format Conference or Workshop Item
id upm-32215
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T09:14:07Z
publishDate 2012
recordtype eprints
repository_type Digital Repository
spelling upm-322152017-01-09T08:39:09Z http://psasir.upm.edu.my/id/eprint/32215/ Construction and use of a custom-made digital pressure threshold device in cats Basiri, Bita Chen, Hee Chong Dehzangi, Arash A digital pressure threshold device was constructed for use in cats. It contained a force sensing resistor (FSR), connected to a measuring device with a 1 meter wire, and powered with two 9 volt batteries. Following calibration, the FSR can be applied quickly and conveniently to obtain pressure threshold of the metatarsal pad in cats. This device was used to compare the pressure thresholds of tramadol hydrochloride at 4 mg/kg, SC, and acepromazine at 0.1 mg/kg, SC. Six cats were used in a randomized cross over design with two weeks wash out period. The results showed that tramadol increased the pressure thresholds at 3, 4, 5 and 6 hours post injection while acepromazine did not change the pressure thresholds significantly. This trial demonstrated that measurement of pressure thresholds at the metatarsal pad can be used to differentiate if a treatment had antinociceptive property. As the device is portable and easily operated, it would be a useful tool to study analgesics and their efficacies in clinical setting. 2012 Conference or Workshop Item NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf Basiri, Bita and Chen, Hee Chong and Dehzangi, Arash (2012) Construction and use of a custom-made digital pressure threshold device in cats. In: International Conference on One Health and 24th VAM Congress 2012, 21-23 Sept. 2012, Marriott Putrajaya. (pp. 177-179).
spellingShingle Basiri, Bita
Chen, Hee Chong
Dehzangi, Arash
Construction and use of a custom-made digital pressure threshold device in cats
title Construction and use of a custom-made digital pressure threshold device in cats
title_full Construction and use of a custom-made digital pressure threshold device in cats
title_fullStr Construction and use of a custom-made digital pressure threshold device in cats
title_full_unstemmed Construction and use of a custom-made digital pressure threshold device in cats
title_short Construction and use of a custom-made digital pressure threshold device in cats
title_sort construction and use of a custom-made digital pressure threshold device in cats
url http://psasir.upm.edu.my/id/eprint/32215/
http://psasir.upm.edu.my/id/eprint/32215/1/32215.pdf