Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line

This paper investigates the effect of design parameters on the induced voltages on a distribution power line. This investigation is based on perfect ground conductivity, single stroke lightning and lightning without branches. The design of the parameters includes, d, the striking distance of the lig...

Full description

Bibliographic Details
Main Authors: Rameli, Nabilah, Ab Kadir, Mohd Zainal Abidin, Izadi, Mahdi, Gomes, Chandima, Jasni, Jasronita
Format: Article
Language:English
Published: Penerbit Universiti Teknologi Malaysia 2013
Online Access:http://psasir.upm.edu.my/id/eprint/28730/
http://psasir.upm.edu.my/id/eprint/28730/1/Evaluation%20of%20lightning%20induced%20voltage%20due%20to%20the%20effect%20of%20design%20parameters%20on%20medium%20voltage%20distribution%20line.pdf
_version_ 1848846197246132224
author Rameli, Nabilah
Ab Kadir, Mohd Zainal Abidin
Izadi, Mahdi
Gomes, Chandima
Jasni, Jasronita
author_facet Rameli, Nabilah
Ab Kadir, Mohd Zainal Abidin
Izadi, Mahdi
Gomes, Chandima
Jasni, Jasronita
author_sort Rameli, Nabilah
building UPM Institutional Repository
collection Online Access
description This paper investigates the effect of design parameters on the induced voltages on a distribution power line. This investigation is based on perfect ground conductivity, single stroke lightning and lightning without branches. The design of the parameters includes, d, the striking distance of the lightning, h, the height of the conductor, and r, the diameter of the conductor, all of which are elements that produce the variations in the induced voltage on a distribution power line with respect to a vertical or an inclined lightning channel. Thus, the outcome of this investigation can act as a guide for utility companies or other power engineers in order to plan an appropriate protection scheme for a distribution power line.
first_indexed 2025-11-15T08:58:53Z
format Article
id upm-28730
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T08:58:53Z
publishDate 2013
publisher Penerbit Universiti Teknologi Malaysia
recordtype eprints
repository_type Digital Repository
spelling upm-287302019-11-21T00:13:49Z http://psasir.upm.edu.my/id/eprint/28730/ Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line Rameli, Nabilah Ab Kadir, Mohd Zainal Abidin Izadi, Mahdi Gomes, Chandima Jasni, Jasronita This paper investigates the effect of design parameters on the induced voltages on a distribution power line. This investigation is based on perfect ground conductivity, single stroke lightning and lightning without branches. The design of the parameters includes, d, the striking distance of the lightning, h, the height of the conductor, and r, the diameter of the conductor, all of which are elements that produce the variations in the induced voltage on a distribution power line with respect to a vertical or an inclined lightning channel. Thus, the outcome of this investigation can act as a guide for utility companies or other power engineers in order to plan an appropriate protection scheme for a distribution power line. Penerbit Universiti Teknologi Malaysia 2013 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/28730/1/Evaluation%20of%20lightning%20induced%20voltage%20due%20to%20the%20effect%20of%20design%20parameters%20on%20medium%20voltage%20distribution%20line.pdf Rameli, Nabilah and Ab Kadir, Mohd Zainal Abidin and Izadi, Mahdi and Gomes, Chandima and Jasni, Jasronita (2013) Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line. Jurnal Teknologi, 64 (4). pp. 151-155. ISSN 0127–9696; ESSN: 2180–3722 http://www.jurnalteknologi.utm.my/index.php/jurnalteknologi/article/view/2118
spellingShingle Rameli, Nabilah
Ab Kadir, Mohd Zainal Abidin
Izadi, Mahdi
Gomes, Chandima
Jasni, Jasronita
Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line
title Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line
title_full Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line
title_fullStr Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line
title_full_unstemmed Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line
title_short Evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line
title_sort evaluation of lightning induced voltage due to the effect of design parameters on medium voltage distribution line
url http://psasir.upm.edu.my/id/eprint/28730/
http://psasir.upm.edu.my/id/eprint/28730/
http://psasir.upm.edu.my/id/eprint/28730/1/Evaluation%20of%20lightning%20induced%20voltage%20due%20to%20the%20effect%20of%20design%20parameters%20on%20medium%20voltage%20distribution%20line.pdf