Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall.

Recently implementation of viscous damper devices as seismic energy dissipation attracts a lot of civil engineer interested due to effect of dampers in diminishing of earthquake loading. Furthermore along lateral load resistance systems, shear wall has better resistance performance by providing enou...

Full description

Bibliographic Details
Main Authors: Hejazi, Farzad, Jaafar, Mohd Saleh, Fateh, Amir, Omer, Abdilahi Bashir
Format: Article
Language:English
English
Published: 2013
Online Access:http://psasir.upm.edu.my/id/eprint/28537/
http://psasir.upm.edu.my/id/eprint/28537/1/Seismic%20Response%20Evaluation%20of%20Reinforced%20Structure%20with%20Embedded%20Viscous%20Damper%20in%20Shear%20Wall.pdf
_version_ 1848846144389513216
author Hejazi, Farzad
Jaafar, Mohd Saleh
Fateh, Amir
Omer, Abdilahi Bashir
author_facet Hejazi, Farzad
Jaafar, Mohd Saleh
Fateh, Amir
Omer, Abdilahi Bashir
author_sort Hejazi, Farzad
building UPM Institutional Repository
collection Online Access
description Recently implementation of viscous damper devices as seismic energy dissipation attracts a lot of civil engineer interested due to effect of dampers in diminishing of earthquake loading. Furthermore along lateral load resistance systems, shear wall has better resistance performance by providing enough stiffness to the structure. But the overall weight of building is dramatically increased whenever shear walls are used as lateral resistance system. So, in present study an attempt has been made to evaluate seismic response of reinforced concrete structure which is equipped with viscous damper inside of shear walls. So, seismic response assessment carried out by aid of time history analysis and the results emerged in terms of average story displacement, axial force, moment and torsion in critical elements. Various models with different shear wall arrangement and embedded viscous damper layouts were subjected to earthquake excitation and response investigated. The results indicated that the best performance achieved when the viscous damper located at the top of the shear wall frame structure with the highest reduction percentage of axial forces, moment at the base of the shear wall, torsion and base shear values.
first_indexed 2025-11-15T08:58:02Z
format Article
id upm-28537
institution Universiti Putra Malaysia
institution_category Local University
language English
English
last_indexed 2025-11-15T08:58:02Z
publishDate 2013
recordtype eprints
repository_type Digital Repository
spelling upm-285372015-09-11T03:19:14Z http://psasir.upm.edu.my/id/eprint/28537/ Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall. Hejazi, Farzad Jaafar, Mohd Saleh Fateh, Amir Omer, Abdilahi Bashir Recently implementation of viscous damper devices as seismic energy dissipation attracts a lot of civil engineer interested due to effect of dampers in diminishing of earthquake loading. Furthermore along lateral load resistance systems, shear wall has better resistance performance by providing enough stiffness to the structure. But the overall weight of building is dramatically increased whenever shear walls are used as lateral resistance system. So, in present study an attempt has been made to evaluate seismic response of reinforced concrete structure which is equipped with viscous damper inside of shear walls. So, seismic response assessment carried out by aid of time history analysis and the results emerged in terms of average story displacement, axial force, moment and torsion in critical elements. Various models with different shear wall arrangement and embedded viscous damper layouts were subjected to earthquake excitation and response investigated. The results indicated that the best performance achieved when the viscous damper located at the top of the shear wall frame structure with the highest reduction percentage of axial forces, moment at the base of the shear wall, torsion and base shear values. 2013 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/28537/1/Seismic%20Response%20Evaluation%20of%20Reinforced%20Structure%20with%20Embedded%20Viscous%20Damper%20in%20Shear%20Wall.pdf Hejazi, Farzad and Jaafar, Mohd Saleh and Fateh, Amir and Omer, Abdilahi Bashir (2013) Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall. International Journal of Advancements Civil Structural and Environmental Engineering, 1 (1). pp. 109-112. English
spellingShingle Hejazi, Farzad
Jaafar, Mohd Saleh
Fateh, Amir
Omer, Abdilahi Bashir
Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall.
title Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall.
title_full Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall.
title_fullStr Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall.
title_full_unstemmed Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall.
title_short Seismic Response Evaluation of Reinforced Structure with Embedded Viscous Damper in Shear Wall.
title_sort seismic response evaluation of reinforced structure with embedded viscous damper in shear wall.
url http://psasir.upm.edu.my/id/eprint/28537/
http://psasir.upm.edu.my/id/eprint/28537/1/Seismic%20Response%20Evaluation%20of%20Reinforced%20Structure%20with%20Embedded%20Viscous%20Damper%20in%20Shear%20Wall.pdf