Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur

Thermal comfort conditions in residential buildings vary according to the designs, modifications of the house and adaptation of the occupants. While air-conditioning is the most popular form of adaptation, natural ventilation is still relied upon for some parts. This study investigates thermal co...

Full description

Bibliographic Details
Main Authors: Sadafi, Nasibeh, Salleh, Elias, Lim, Chin Haw, Jaafar, Mohd Fakri Zaky
Format: Article
Language:English
Published: Faculty of Design & Architecture, Universiti Putra Malaysia 2007
Online Access:http://psasir.upm.edu.my/id/eprint/2471/
http://psasir.upm.edu.my/id/eprint/2471/1/2-Nasibeh_PDF.pdf
_version_ 1848839256634556416
author Sadafi, Nasibeh
Salleh, Elias
Lim, Chin Haw
Jaafar, Mohd Fakri Zaky
author_facet Sadafi, Nasibeh
Salleh, Elias
Lim, Chin Haw
Jaafar, Mohd Fakri Zaky
author_sort Sadafi, Nasibeh
building UPM Institutional Repository
collection Online Access
description Thermal comfort conditions in residential buildings vary according to the designs, modifications of the house and adaptation of the occupants. While air-conditioning is the most popular form of adaptation, natural ventilation is still relied upon for some parts. This study investigates thermal comfort performance of terrace housing in Kuala Lumpur, Malaysia, using Fanger’s predicted mean vote (PMV) thermal comfort index. A case study of a terrace house was carried out in a housing scheme in Kuala Lumpur where field measurement was conducted during a three-day recording in naturallyventilated space of the house. The study showed that the house was thermally comfortable for almost fifteen hours during day and night. Comfort conditions mostly occurred during night hours while around noon hours could be considered as critical times. To improve the thermal conditions, ceiling fans were used to increase the indoor air velocity. However, it was observed that this measure did not improve the thermal comfort condition when the air temperature had reached its maximum level. On the other hand, reducing the solar heat gain could improve the thermal comfort condition of the house.
first_indexed 2025-11-15T07:08:34Z
format Article
id upm-2471
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T07:08:34Z
publishDate 2007
publisher Faculty of Design & Architecture, Universiti Putra Malaysia
recordtype eprints
repository_type Digital Repository
spelling upm-24712015-10-07T00:54:02Z http://psasir.upm.edu.my/id/eprint/2471/ Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur Sadafi, Nasibeh Salleh, Elias Lim, Chin Haw Jaafar, Mohd Fakri Zaky Thermal comfort conditions in residential buildings vary according to the designs, modifications of the house and adaptation of the occupants. While air-conditioning is the most popular form of adaptation, natural ventilation is still relied upon for some parts. This study investigates thermal comfort performance of terrace housing in Kuala Lumpur, Malaysia, using Fanger’s predicted mean vote (PMV) thermal comfort index. A case study of a terrace house was carried out in a housing scheme in Kuala Lumpur where field measurement was conducted during a three-day recording in naturallyventilated space of the house. The study showed that the house was thermally comfortable for almost fifteen hours during day and night. Comfort conditions mostly occurred during night hours while around noon hours could be considered as critical times. To improve the thermal conditions, ceiling fans were used to increase the indoor air velocity. However, it was observed that this measure did not improve the thermal comfort condition when the air temperature had reached its maximum level. On the other hand, reducing the solar heat gain could improve the thermal comfort condition of the house. Faculty of Design & Architecture, Universiti Putra Malaysia 2007-12 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/2471/1/2-Nasibeh_PDF.pdf Sadafi, Nasibeh and Salleh, Elias and Lim, Chin Haw and Jaafar, Mohd Fakri Zaky (2007) Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur. ALAM CIPTA, International Journal on Sustainable Tropical Design Research & Practice, 3 (1). pp. 15-24. ISSN 1823-7231; ESSN: 2289-3687 http://frsb.upm.edu.my/alamcipta/index.php/alamcipta/article/view/36/21
spellingShingle Sadafi, Nasibeh
Salleh, Elias
Lim, Chin Haw
Jaafar, Mohd Fakri Zaky
Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur
title Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur
title_full Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur
title_fullStr Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur
title_full_unstemmed Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur
title_short Potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in Kuala Lumpur
title_sort potential design parameters for enhancing thermal comfort in tropical terrace house: a case study in kuala lumpur
url http://psasir.upm.edu.my/id/eprint/2471/
http://psasir.upm.edu.my/id/eprint/2471/
http://psasir.upm.edu.my/id/eprint/2471/1/2-Nasibeh_PDF.pdf