Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera

This paper presents the preliminary results of the new low energy high resolution wire-mesh collimator gamma camera in mapping breast cancer cells, by employing 140 keV photons of Technetium-99 m radionuclide tracer. The complete model of photons propagation and detection, as well as the human cells...

Full description

Bibliographic Details
Main Authors: Saripan, M. Iqbal, Mohd Saad, Wira Hidayat, Hashim, Suhairul, Mahmud, Rozi, Nordin, Abdul Jalil, Mahdi, Mohd Adzir
Format: Article
Language:English
Published: IEEE 2009
Online Access:http://psasir.upm.edu.my/id/eprint/15728/
http://psasir.upm.edu.my/id/eprint/15728/1/Monte%20Carlo%20simulation%20on%20breast%20cancer%20detection%20using%20wire%20mesh%20collimator%20gamma%20camera.pdf
_version_ 1848842759879786496
author Saripan, M. Iqbal
Mohd Saad, Wira Hidayat
Hashim, Suhairul
Mahmud, Rozi
Nordin, Abdul Jalil
Mahdi, Mohd Adzir
author_facet Saripan, M. Iqbal
Mohd Saad, Wira Hidayat
Hashim, Suhairul
Mahmud, Rozi
Nordin, Abdul Jalil
Mahdi, Mohd Adzir
author_sort Saripan, M. Iqbal
building UPM Institutional Repository
collection Online Access
description This paper presents the preliminary results of the new low energy high resolution wire-mesh collimator gamma camera in mapping breast cancer cells, by employing 140 keV photons of Technetium-99 m radionuclide tracer. The complete model of photons propagation and detection, as well as the human cells activities are simulated using Monte Carlo N-Particle code. Abnormal cells of different tumor to background values are investigated, and the results from the conventional collimator and wire-mesh collimator are compared. The results are evaluated in terms of the collimator sensitivity and the contrast to background ratio. In our assessment, the wire mesh collimator gamma camera yields slightly better results than the multihole collimator for sensitivity, however produces insignificant performance in the contrast to background evaluation.
first_indexed 2025-11-15T08:04:15Z
format Article
id upm-15728
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T08:04:15Z
publishDate 2009
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling upm-157282018-10-25T08:03:36Z http://psasir.upm.edu.my/id/eprint/15728/ Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera Saripan, M. Iqbal Mohd Saad, Wira Hidayat Hashim, Suhairul Mahmud, Rozi Nordin, Abdul Jalil Mahdi, Mohd Adzir This paper presents the preliminary results of the new low energy high resolution wire-mesh collimator gamma camera in mapping breast cancer cells, by employing 140 keV photons of Technetium-99 m radionuclide tracer. The complete model of photons propagation and detection, as well as the human cells activities are simulated using Monte Carlo N-Particle code. Abnormal cells of different tumor to background values are investigated, and the results from the conventional collimator and wire-mesh collimator are compared. The results are evaluated in terms of the collimator sensitivity and the contrast to background ratio. In our assessment, the wire mesh collimator gamma camera yields slightly better results than the multihole collimator for sensitivity, however produces insignificant performance in the contrast to background evaluation. IEEE 2009-06 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/15728/1/Monte%20Carlo%20simulation%20on%20breast%20cancer%20detection%20using%20wire%20mesh%20collimator%20gamma%20camera.pdf Saripan, M. Iqbal and Mohd Saad, Wira Hidayat and Hashim, Suhairul and Mahmud, Rozi and Nordin, Abdul Jalil and Mahdi, Mohd Adzir (2009) Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera. IEEE Transactions on Nuclear Science, 56 (3). pp. 1321-1324. ISSN 0018-9499; ESSN: 1558-1578 https://ieeexplore.ieee.org/document/5076050 10.1109/TNS.2008.2012058
spellingShingle Saripan, M. Iqbal
Mohd Saad, Wira Hidayat
Hashim, Suhairul
Mahmud, Rozi
Nordin, Abdul Jalil
Mahdi, Mohd Adzir
Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera
title Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera
title_full Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera
title_fullStr Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera
title_full_unstemmed Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera
title_short Monte Carlo simulation on breast cancer detection using wire mesh collimator gamma camera
title_sort monte carlo simulation on breast cancer detection using wire mesh collimator gamma camera
url http://psasir.upm.edu.my/id/eprint/15728/
http://psasir.upm.edu.my/id/eprint/15728/
http://psasir.upm.edu.my/id/eprint/15728/
http://psasir.upm.edu.my/id/eprint/15728/1/Monte%20Carlo%20simulation%20on%20breast%20cancer%20detection%20using%20wire%20mesh%20collimator%20gamma%20camera.pdf