Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer

This paper presents an investigation on the sensitivity of frequency response of a 500 kVA, 11/0.433 kV distribution transformer with and without the presence of a winding clamping structure. Frequency response analysis (FRA) measurements of multiple test configurations were carried out with and wit...

Full description

Bibliographic Details
Main Authors: Murthy, Avinash Srikanta, Azis, Norhafiz, Al-Ameri, Salem, Mohd Yousof, Mohd Fairouz, Jasni, Jasronita, Talib, Mohd Aizam
Format: Article
Language:English
Published: MDPI 2018
Online Access:http://psasir.upm.edu.my/id/eprint/15365/
http://psasir.upm.edu.my/id/eprint/15365/1/15365.pdf
_version_ 1848842657163378688
author Murthy, Avinash Srikanta
Azis, Norhafiz
Al-Ameri, Salem
Mohd Yousof, Mohd Fairouz
Jasni, Jasronita
Talib, Mohd Aizam
author_facet Murthy, Avinash Srikanta
Azis, Norhafiz
Al-Ameri, Salem
Mohd Yousof, Mohd Fairouz
Jasni, Jasronita
Talib, Mohd Aizam
author_sort Murthy, Avinash Srikanta
building UPM Institutional Repository
collection Online Access
description This paper presents an investigation on the sensitivity of frequency response of a 500 kVA, 11/0.433 kV distribution transformer with and without the presence of a winding clamping structure. Frequency response analysis (FRA) measurements of multiple test configurations were carried out with and without the presence of a winding clamping structure. Statistical analyses based on Pearson’s correlation coefficient (PCC), Spearman’s correlation coefficient (SCC), Kendall’s correlation coefficient (KCC), cross-correlation coefficient (CCF), root mean square error (RMSE), absolute sum of logarithmic error (ASLE), hypothesis test (F-test) and relative factor (RF) were applied to determine the effect of the winding clamping structure. It was found that the removal of the winding clamping structure has an impact on the frequency response signature at the frequency less than 2 kHz during offline measurement. It was found that ASLE and F-test are suitable methods that can be used to indicate the variation of frequency response caused by clamping structure removal of the distribution transformer under study.
first_indexed 2025-11-15T08:02:37Z
format Article
id upm-15365
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T08:02:37Z
publishDate 2018
publisher MDPI
recordtype eprints
repository_type Digital Repository
spelling upm-153652019-07-08T07:30:42Z http://psasir.upm.edu.my/id/eprint/15365/ Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer Murthy, Avinash Srikanta Azis, Norhafiz Al-Ameri, Salem Mohd Yousof, Mohd Fairouz Jasni, Jasronita Talib, Mohd Aizam This paper presents an investigation on the sensitivity of frequency response of a 500 kVA, 11/0.433 kV distribution transformer with and without the presence of a winding clamping structure. Frequency response analysis (FRA) measurements of multiple test configurations were carried out with and without the presence of a winding clamping structure. Statistical analyses based on Pearson’s correlation coefficient (PCC), Spearman’s correlation coefficient (SCC), Kendall’s correlation coefficient (KCC), cross-correlation coefficient (CCF), root mean square error (RMSE), absolute sum of logarithmic error (ASLE), hypothesis test (F-test) and relative factor (RF) were applied to determine the effect of the winding clamping structure. It was found that the removal of the winding clamping structure has an impact on the frequency response signature at the frequency less than 2 kHz during offline measurement. It was found that ASLE and F-test are suitable methods that can be used to indicate the variation of frequency response caused by clamping structure removal of the distribution transformer under study. MDPI 2018 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/15365/1/15365.pdf Murthy, Avinash Srikanta and Azis, Norhafiz and Al-Ameri, Salem and Mohd Yousof, Mohd Fairouz and Jasni, Jasronita and Talib, Mohd Aizam (2018) Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer. Energies, 11 (9). art. no. 2307. pp. 1-13. ISSN 1996-1073 https://www.mdpi.com/1996-1073/11/9/2307 10.3390/en11092307
spellingShingle Murthy, Avinash Srikanta
Azis, Norhafiz
Al-Ameri, Salem
Mohd Yousof, Mohd Fairouz
Jasni, Jasronita
Talib, Mohd Aizam
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
title Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
title_full Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
title_fullStr Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
title_full_unstemmed Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
title_short Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
title_sort investigation of the effect of winding clamping structure on frequency response signature of 11 kv distribution transformer
url http://psasir.upm.edu.my/id/eprint/15365/
http://psasir.upm.edu.my/id/eprint/15365/
http://psasir.upm.edu.my/id/eprint/15365/
http://psasir.upm.edu.my/id/eprint/15365/1/15365.pdf