Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital

This study aimed to estimate radiation dose and to assess the probability of cancer induction risk among patients who underwent mammography procedure in tertiary hospital in Dubai. After obtained approval from the research ethic committee,155 female patients with an average age of 55.5 ± 12.7 years-...

Full description

Bibliographic Details
Main Authors: Abdulwahid Noor, Kaltham, Mohd Norsuddin, Norhashimah, Che Isa, Iza Nurzawani, Murat, Husain, Abdul Karim, Muhammad Khalis
Format: Article
Language:English
Published: Elsevier Ltd 2025
Online Access:http://psasir.upm.edu.my/id/eprint/121155/
http://psasir.upm.edu.my/id/eprint/121155/1/121155.pdf
_version_ 1848868307705266176
author Abdulwahid Noor, Kaltham
Mohd Norsuddin, Norhashimah
Che Isa, Iza Nurzawani
Murat, Husain
Abdul Karim, Muhammad Khalis
author_facet Abdulwahid Noor, Kaltham
Mohd Norsuddin, Norhashimah
Che Isa, Iza Nurzawani
Murat, Husain
Abdul Karim, Muhammad Khalis
author_sort Abdulwahid Noor, Kaltham
building UPM Institutional Repository
collection Online Access
description This study aimed to estimate radiation dose and to assess the probability of cancer induction risk among patients who underwent mammography procedure in tertiary hospital in Dubai. After obtained approval from the research ethic committee,155 female patients with an average age of 55.5 ± 12.7 years-old were selected as subjects. Acquisition parameter, tube potential, tube current, compression force, and entrance dose were recorded and analyzed. The Mean Glandular Dose (MGD) were determined by applying the Dance formula, considering the entrance surface air kerma (ESAK) and other conversion coefficients. Patient age-data was used to assess the cancer induction risk from the acquisition, based on Biological Effects of Ionizing Radiation VII (BEIR VII) report, and standardizing the breast thickness. The MGD ranged between 0.7 and 3.5 mGy for medio-lateral oblique (MLO) and for cranio-caudal (CC) projections, respectively. The median MGD for CC lies between 1.4 mGy and 2.1 mGy, with an average of 1.7 mGy. Additionally, the MGD for the 3rd quartile spans a two-fold range. In a population of 100,000 exposed to MLO projection, the cancer incidence risk for a 37-year-old female was 6 times higher than that of a 60-year-old female, at 3.2 out of 100,000 and 0.5 out of 100,000, respectively. The LAR for the 35–45 years age group is 1.91 ± 0.66, decreasing to 0.27 ± 0.07 for those over 65 years. The CC view also shows a decrease from 1.73 ± 0.57 to 0.23 ± 0.04. The mammographic screening radiation dose and the risks that have been found in Dubai all fall within the recommended range, thereby calling for more works of research to determine the progress made in radiation protection. The study has provided additional evidence that the radiation dose used in current practice can be improved.
first_indexed 2025-11-15T14:50:19Z
format Article
id upm-121155
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T14:50:19Z
publishDate 2025
publisher Elsevier Ltd
recordtype eprints
repository_type Digital Repository
spelling upm-1211552025-10-28T06:37:49Z http://psasir.upm.edu.my/id/eprint/121155/ Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital Abdulwahid Noor, Kaltham Mohd Norsuddin, Norhashimah Che Isa, Iza Nurzawani Murat, Husain Abdul Karim, Muhammad Khalis This study aimed to estimate radiation dose and to assess the probability of cancer induction risk among patients who underwent mammography procedure in tertiary hospital in Dubai. After obtained approval from the research ethic committee,155 female patients with an average age of 55.5 ± 12.7 years-old were selected as subjects. Acquisition parameter, tube potential, tube current, compression force, and entrance dose were recorded and analyzed. The Mean Glandular Dose (MGD) were determined by applying the Dance formula, considering the entrance surface air kerma (ESAK) and other conversion coefficients. Patient age-data was used to assess the cancer induction risk from the acquisition, based on Biological Effects of Ionizing Radiation VII (BEIR VII) report, and standardizing the breast thickness. The MGD ranged between 0.7 and 3.5 mGy for medio-lateral oblique (MLO) and for cranio-caudal (CC) projections, respectively. The median MGD for CC lies between 1.4 mGy and 2.1 mGy, with an average of 1.7 mGy. Additionally, the MGD for the 3rd quartile spans a two-fold range. In a population of 100,000 exposed to MLO projection, the cancer incidence risk for a 37-year-old female was 6 times higher than that of a 60-year-old female, at 3.2 out of 100,000 and 0.5 out of 100,000, respectively. The LAR for the 35–45 years age group is 1.91 ± 0.66, decreasing to 0.27 ± 0.07 for those over 65 years. The CC view also shows a decrease from 1.73 ± 0.57 to 0.23 ± 0.04. The mammographic screening radiation dose and the risks that have been found in Dubai all fall within the recommended range, thereby calling for more works of research to determine the progress made in radiation protection. The study has provided additional evidence that the radiation dose used in current practice can be improved. Elsevier Ltd 2025 Article NonPeerReviewed text en http://psasir.upm.edu.my/id/eprint/121155/1/121155.pdf Abdulwahid Noor, Kaltham and Mohd Norsuddin, Norhashimah and Che Isa, Iza Nurzawani and Murat, Husain and Abdul Karim, Muhammad Khalis (2025) Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital. Applied Radiation and Isotopes, 221 (undefined). art. no. 111801. undefined-undefined. ISSN 0969-8043; eISSN: 1872-9800 https://linkinghub.elsevier.com/retrieve/pii/S0969804325001460 10.1016/j.apradiso.2025.111801
spellingShingle Abdulwahid Noor, Kaltham
Mohd Norsuddin, Norhashimah
Che Isa, Iza Nurzawani
Murat, Husain
Abdul Karim, Muhammad Khalis
Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital
title Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital
title_full Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital
title_fullStr Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital
title_full_unstemmed Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital
title_short Radiation dose and cancer induction risk from diagnostic mammography in Dubai tertiary hospital
title_sort radiation dose and cancer induction risk from diagnostic mammography in dubai tertiary hospital
url http://psasir.upm.edu.my/id/eprint/121155/
http://psasir.upm.edu.my/id/eprint/121155/
http://psasir.upm.edu.my/id/eprint/121155/
http://psasir.upm.edu.my/id/eprint/121155/1/121155.pdf