Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector

An energy crisis is caused by the world's population expansion and growing energy consumption by global civilization, which encourages the usage of renewable energy technologies such as solar thermal collectors. Inefficient heat transmission lowers energy conversion and collector performance. T...

Full description

Bibliographic Details
Main Authors: Afham Rahmat, Muhammad Aqil, Ibrahim, Adnan, Al-Aribe, Khaled M., Syafiq Bin Mustaffa, Muhammad Ubaidah, Harmailil, Ihsan Okta, Ud Din, Sahibzada Imad
Format: Article
Language:English
Published: Elsevier Ltd 2025
Online Access:http://psasir.upm.edu.my/id/eprint/120790/
http://psasir.upm.edu.my/id/eprint/120790/1/120790.pdf
_version_ 1848868227628662784
author Afham Rahmat, Muhammad Aqil
Ibrahim, Adnan
Al-Aribe, Khaled M.
Syafiq Bin Mustaffa, Muhammad Ubaidah
Harmailil, Ihsan Okta
Ud Din, Sahibzada Imad
author_facet Afham Rahmat, Muhammad Aqil
Ibrahim, Adnan
Al-Aribe, Khaled M.
Syafiq Bin Mustaffa, Muhammad Ubaidah
Harmailil, Ihsan Okta
Ud Din, Sahibzada Imad
author_sort Afham Rahmat, Muhammad Aqil
building UPM Institutional Repository
collection Online Access
description An energy crisis is caused by the world's population expansion and growing energy consumption by global civilization, which encourages the usage of renewable energy technologies such as solar thermal collectors. Inefficient heat transmission lowers energy conversion and collector performance. This research aims to utilize a multi-level array of hollow semi-stadium fins (HSSF) with baffles to evaluate experimentally the double-pass solar air collector energy utilization. The proposed collectors with baffles and 1:2 and 1:4 multi-level spacing gaps are compared to the flat plate design at mass flow rates of 0.01-0.08 kg/s and irradiances of 400-800 W/m2. The experimental findings are verified with numerical and previously experimental studies. The findings indicated that the newly double-pass solar collector achieved a maximum thermal efficiency of 77.70 % at 800 W/m2, the highest useful energy of 934.83 Watts, and the highest enhancement efficiency of 30.67 %, indicating better performance than the flat plate design. Optimal efficiency was found at flow rates of 0.04 kg/s (400 W/m2) and 0.07 kg/s (600-800 W/m2). Increasing mass flow rates reduces friction factors while raising pressure drops. Validation with numerical results contains a 0.67-4.96 % error. Field-based experimental research, exergy and thermohydraulic studies, and economic and environmental studies are recommended to evaluate the design's effectiveness and feasibility.
first_indexed 2025-11-15T14:49:03Z
format Article
id upm-120790
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T14:49:03Z
publishDate 2025
publisher Elsevier Ltd
recordtype eprints
repository_type Digital Repository
spelling upm-1207902025-10-10T03:12:46Z http://psasir.upm.edu.my/id/eprint/120790/ Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector Afham Rahmat, Muhammad Aqil Ibrahim, Adnan Al-Aribe, Khaled M. Syafiq Bin Mustaffa, Muhammad Ubaidah Harmailil, Ihsan Okta Ud Din, Sahibzada Imad An energy crisis is caused by the world's population expansion and growing energy consumption by global civilization, which encourages the usage of renewable energy technologies such as solar thermal collectors. Inefficient heat transmission lowers energy conversion and collector performance. This research aims to utilize a multi-level array of hollow semi-stadium fins (HSSF) with baffles to evaluate experimentally the double-pass solar air collector energy utilization. The proposed collectors with baffles and 1:2 and 1:4 multi-level spacing gaps are compared to the flat plate design at mass flow rates of 0.01-0.08 kg/s and irradiances of 400-800 W/m2. The experimental findings are verified with numerical and previously experimental studies. The findings indicated that the newly double-pass solar collector achieved a maximum thermal efficiency of 77.70 % at 800 W/m2, the highest useful energy of 934.83 Watts, and the highest enhancement efficiency of 30.67 %, indicating better performance than the flat plate design. Optimal efficiency was found at flow rates of 0.04 kg/s (400 W/m2) and 0.07 kg/s (600-800 W/m2). Increasing mass flow rates reduces friction factors while raising pressure drops. Validation with numerical results contains a 0.67-4.96 % error. Field-based experimental research, exergy and thermohydraulic studies, and economic and environmental studies are recommended to evaluate the design's effectiveness and feasibility. Elsevier Ltd 2025 Article PeerReviewed text en cc_by_4 http://psasir.upm.edu.my/id/eprint/120790/1/120790.pdf Afham Rahmat, Muhammad Aqil and Ibrahim, Adnan and Al-Aribe, Khaled M. and Syafiq Bin Mustaffa, Muhammad Ubaidah and Harmailil, Ihsan Okta and Ud Din, Sahibzada Imad (2025) Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector. Case Studies in Thermal Engineering, 71. art. no. 106165. pp. 1-20. ISSN 2214-157X https://www.sciencedirect.com/science/article/pii/S2214157X25004253?via%3Dihub 10.1016/j.csite.2025.106165
spellingShingle Afham Rahmat, Muhammad Aqil
Ibrahim, Adnan
Al-Aribe, Khaled M.
Syafiq Bin Mustaffa, Muhammad Ubaidah
Harmailil, Ihsan Okta
Ud Din, Sahibzada Imad
Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector
title Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector
title_full Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector
title_fullStr Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector
title_full_unstemmed Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector
title_short Experimental analysis on the effect of multi-level array hollow semi-stadium fins (HSSF) and baffles on solar thermal air collector
title_sort experimental analysis on the effect of multi-level array hollow semi-stadium fins (hssf) and baffles on solar thermal air collector
url http://psasir.upm.edu.my/id/eprint/120790/
http://psasir.upm.edu.my/id/eprint/120790/
http://psasir.upm.edu.my/id/eprint/120790/
http://psasir.upm.edu.my/id/eprint/120790/1/120790.pdf