Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters

The thermal unit operation used in milk processing causes changes in milk nutritional quality. Hence, optimising the non-thermal ultrasonication process at 25°C can be a potential method to retain milk quality. The objective of this research is to optimise the ultrasonication process of standardise...

Full description

Bibliographic Details
Main Authors: Mohd Yaakub, Nurul'azah, Mustapa Kamal, Siti Mazlina, Chin, Nyuk Ling, Julmohammad, Norliza, Therdthai, Nantawan, Sulaiman, Alifdalino
Format: Article
Language:English
Published: HH Publisher 2024
Online Access:http://psasir.upm.edu.my/id/eprint/120228/
http://psasir.upm.edu.my/id/eprint/120228/1/120228.pdf
_version_ 1848868142769504256
author Mohd Yaakub, Nurul'azah
Mustapa Kamal, Siti Mazlina
Chin, Nyuk Ling
Julmohammad, Norliza
Therdthai, Nantawan
Sulaiman, Alifdalino
author_facet Mohd Yaakub, Nurul'azah
Mustapa Kamal, Siti Mazlina
Chin, Nyuk Ling
Julmohammad, Norliza
Therdthai, Nantawan
Sulaiman, Alifdalino
author_sort Mohd Yaakub, Nurul'azah
building UPM Institutional Repository
collection Online Access
description The thermal unit operation used in milk processing causes changes in milk nutritional quality. Hence, optimising the non-thermal ultrasonication process at 25°C can be a potential method to retain milk quality. The objective of this research is to optimise the ultrasonication process of standardised fresh cow's milk at various fat percentages and elucidate its effect on nutritional values using response surface methodology (RSM). A central composite design based on fat (1–4%); ultrasound amplitude (10–70%), and sonication time (1.5–10.5 min) was used. Data analysis shows that the ultrasonication process significantly (p<0.05) affects the percentage of fat, free fatty acid (FFA), protein, solid non-fat; solid non-fat (SNF), lactose, casein, and total solid (TS). The adjusted R2 for fat, free fatty acid, and TS with goodness-of-fit were 0.940, 0.975, and 0.955, respectively. The generation of FFA in raw cow milk was observed with some ultrasonication conditions. As a conclusion, the processing parameters to get the highest fat and lowest FFA is a combination of 4% milk fat, 10% amplitude, and 1.95 min sonication time with 46.8 J/mL energy density can be applied to control the release of further FFA generation from the milk processing line.
first_indexed 2025-11-15T14:47:42Z
format Article
id upm-120228
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T14:47:42Z
publishDate 2024
publisher HH Publisher
recordtype eprints
repository_type Digital Repository
spelling upm-1202282025-09-26T08:12:03Z http://psasir.upm.edu.my/id/eprint/120228/ Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters Mohd Yaakub, Nurul'azah Mustapa Kamal, Siti Mazlina Chin, Nyuk Ling Julmohammad, Norliza Therdthai, Nantawan Sulaiman, Alifdalino The thermal unit operation used in milk processing causes changes in milk nutritional quality. Hence, optimising the non-thermal ultrasonication process at 25°C can be a potential method to retain milk quality. The objective of this research is to optimise the ultrasonication process of standardised fresh cow's milk at various fat percentages and elucidate its effect on nutritional values using response surface methodology (RSM). A central composite design based on fat (1–4%); ultrasound amplitude (10–70%), and sonication time (1.5–10.5 min) was used. Data analysis shows that the ultrasonication process significantly (p<0.05) affects the percentage of fat, free fatty acid (FFA), protein, solid non-fat; solid non-fat (SNF), lactose, casein, and total solid (TS). The adjusted R2 for fat, free fatty acid, and TS with goodness-of-fit were 0.940, 0.975, and 0.955, respectively. The generation of FFA in raw cow milk was observed with some ultrasonication conditions. As a conclusion, the processing parameters to get the highest fat and lowest FFA is a combination of 4% milk fat, 10% amplitude, and 1.95 min sonication time with 46.8 J/mL energy density can be applied to control the release of further FFA generation from the milk processing line. HH Publisher 2024-10-18 Article PeerReviewed text en cc_by_nc_4 http://psasir.upm.edu.my/id/eprint/120228/1/120228.pdf Mohd Yaakub, Nurul'azah and Mustapa Kamal, Siti Mazlina and Chin, Nyuk Ling and Julmohammad, Norliza and Therdthai, Nantawan and Sulaiman, Alifdalino (2024) Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters. Advances in Agricultural and Food Research Journal, 5 (2). pp. 1-21. ISSN 2735-1084 https://journals.hh-publisher.com/index.php/AAFRJ/article/view/870 10.36877/aafrj.a0000531
spellingShingle Mohd Yaakub, Nurul'azah
Mustapa Kamal, Siti Mazlina
Chin, Nyuk Ling
Julmohammad, Norliza
Therdthai, Nantawan
Sulaiman, Alifdalino
Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters
title Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters
title_full Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters
title_fullStr Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters
title_full_unstemmed Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters
title_short Optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters
title_sort optimisation of non-thermal ultrasonication process for retaining nutritional quality in cow milk: effects of fat percentage and treatment parameters
url http://psasir.upm.edu.my/id/eprint/120228/
http://psasir.upm.edu.my/id/eprint/120228/
http://psasir.upm.edu.my/id/eprint/120228/
http://psasir.upm.edu.my/id/eprint/120228/1/120228.pdf