Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia

Introduction: Computed tomography (CT) ionising radiation may raise the risk of deterministic consequences and cancer development to the patient. Objective of this study is to determine the updated local DRL of adult CT abdominal examinations using a noise index to indicate the image quality. Materi...

Full description

Bibliographic Details
Main Authors: Mohamad Ariffin, Mohamad Asmawi, Abdul Karim, Muhammad Khalis, Abd Rahman, Mohd Amiruddin, Mohd Zaid, Mohd Hafiz, Harun, Hanif Haspi
Format: Article
Language:English
Published: Universiti Putra Malaysia 2024
Online Access:http://psasir.upm.edu.my/id/eprint/119428/
http://psasir.upm.edu.my/id/eprint/119428/1/119428.pdf
_version_ 1848867962882097152
author Mohamad Ariffin, Mohamad Asmawi
Abdul Karim, Muhammad Khalis
Abd Rahman, Mohd Amiruddin
Mohd Zaid, Mohd Hafiz
Harun, Hanif Haspi
author_facet Mohamad Ariffin, Mohamad Asmawi
Abdul Karim, Muhammad Khalis
Abd Rahman, Mohd Amiruddin
Mohd Zaid, Mohd Hafiz
Harun, Hanif Haspi
author_sort Mohamad Ariffin, Mohamad Asmawi
building UPM Institutional Repository
collection Online Access
description Introduction: Computed tomography (CT) ionising radiation may raise the risk of deterministic consequences and cancer development to the patient. Objective of this study is to determine the updated local DRL of adult CT abdominal examinations using a noise index to indicate the image quality. Materials and methods: A retrospective analysis was conducted on 200 adult patients who underwent CT abdominal examinations between January 2021 and December 2022 and categorised into three body mass index (BMI) groups; group 1, underweight (<18.5), group 2, overweight (≥25.0) and group 3, obese (≥30.0) and statistically compared the radiation dose exposure. The noise magnitude was quantitatively calculated by measuring the standard deviation of the circular region of interest (ROI) at five different locations around the abdominal area. The volume-weighted CT dose index (CTDIvol), the doselength product (DLP), and the effective dose (E) were computed for each BMI group, and DRLs were established with a 50th percentile set. Results: The highest radiation dose for CTDIvol, DLP and E was in group 3 (obese) with mean 15.44 ± 5.43, 769.78 ± 253.25 and 15.37 ± 4.74 respectively. Both DRL and noise reference levels between BMI groups have differed significantly with p-value < 0.05 and <0.70. Conclusion: Patients with varying BMIs had significantly variable radiation doses and noise intensities, necessitating the adjustment of some parameters to satisfy the clinical requirement.
first_indexed 2025-11-15T14:44:50Z
format Article
id upm-119428
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T14:44:50Z
publishDate 2024
publisher Universiti Putra Malaysia
recordtype eprints
repository_type Digital Repository
spelling upm-1194282025-08-22T02:53:52Z http://psasir.upm.edu.my/id/eprint/119428/ Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia Mohamad Ariffin, Mohamad Asmawi Abdul Karim, Muhammad Khalis Abd Rahman, Mohd Amiruddin Mohd Zaid, Mohd Hafiz Harun, Hanif Haspi Introduction: Computed tomography (CT) ionising radiation may raise the risk of deterministic consequences and cancer development to the patient. Objective of this study is to determine the updated local DRL of adult CT abdominal examinations using a noise index to indicate the image quality. Materials and methods: A retrospective analysis was conducted on 200 adult patients who underwent CT abdominal examinations between January 2021 and December 2022 and categorised into three body mass index (BMI) groups; group 1, underweight (<18.5), group 2, overweight (≥25.0) and group 3, obese (≥30.0) and statistically compared the radiation dose exposure. The noise magnitude was quantitatively calculated by measuring the standard deviation of the circular region of interest (ROI) at five different locations around the abdominal area. The volume-weighted CT dose index (CTDIvol), the doselength product (DLP), and the effective dose (E) were computed for each BMI group, and DRLs were established with a 50th percentile set. Results: The highest radiation dose for CTDIvol, DLP and E was in group 3 (obese) with mean 15.44 ± 5.43, 769.78 ± 253.25 and 15.37 ± 4.74 respectively. Both DRL and noise reference levels between BMI groups have differed significantly with p-value < 0.05 and <0.70. Conclusion: Patients with varying BMIs had significantly variable radiation doses and noise intensities, necessitating the adjustment of some parameters to satisfy the clinical requirement. Universiti Putra Malaysia 2024 Article PeerReviewed text en cc_by_4 http://psasir.upm.edu.my/id/eprint/119428/1/119428.pdf Mohamad Ariffin, Mohamad Asmawi and Abdul Karim, Muhammad Khalis and Abd Rahman, Mohd Amiruddin and Mohd Zaid, Mohd Hafiz and Harun, Hanif Haspi (2024) Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia. Malaysian Journal of Medicine and Health Sciences, 20 (suppl.8). pp. 125-131. ISSN 2636-9346 https://medic.upm.edu.my/upload/dokumen/2024102211034717_0220.pdf 10.47836/mjmhs.20.s8.17
spellingShingle Mohamad Ariffin, Mohamad Asmawi
Abdul Karim, Muhammad Khalis
Abd Rahman, Mohd Amiruddin
Mohd Zaid, Mohd Hafiz
Harun, Hanif Haspi
Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia
title Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia
title_full Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia
title_fullStr Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia
title_full_unstemmed Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia
title_short Diagnostic reference level of radiation dose and image quality of adult CT abdominal examination based on body-mass index (BMI) in a tertiary hospital in Malaysia
title_sort diagnostic reference level of radiation dose and image quality of adult ct abdominal examination based on body-mass index (bmi) in a tertiary hospital in malaysia
url http://psasir.upm.edu.my/id/eprint/119428/
http://psasir.upm.edu.my/id/eprint/119428/
http://psasir.upm.edu.my/id/eprint/119428/
http://psasir.upm.edu.my/id/eprint/119428/1/119428.pdf