Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay

Due to rapid industrialization coupled with indiscriminate release of pollutants, the number of polluted rivers in Malaysia has been steadily increasing over the years. Regular monitoring of contaminants, particularly heavy metals, is not feasible due to the steep cost of instrumental monitoring alo...

Full description

Bibliographic Details
Main Authors: Uba, Garba, Halmi, Mohd Izuan Effendi, Shukor, Mohd Yunus
Format: Article
Language:English
Published: Hibiscus Publisher 2024
Online Access:http://psasir.upm.edu.my/id/eprint/118193/
http://psasir.upm.edu.my/id/eprint/118193/1/118193.pdf
_version_ 1848867455086100480
author Uba, Garba
Halmi, Mohd Izuan Effendi
Shukor, Mohd Yunus
author_facet Uba, Garba
Halmi, Mohd Izuan Effendi
Shukor, Mohd Yunus
author_sort Uba, Garba
building UPM Institutional Repository
collection Online Access
description Due to rapid industrialization coupled with indiscriminate release of pollutants, the number of polluted rivers in Malaysia has been steadily increasing over the years. Regular monitoring of contaminants, particularly heavy metals, is not feasible due to the steep cost of instrumental monitoring alone. In this study, a rapid inhibitive enzyme assay using the molybdenum-reducing enzyme from the bacterial isolate 34XW was developed for monitoring mercury. The Mo-reducing enzyme from this bacterium was very sensitive to mercury, with an IC₅₀ confidence interval of 0.0025–0.0029. The inhibition model followed a log(inhibitor) vs. response with variable slope, enabling detection of mercury at the Maximum Permissible Limit (MPL) set by the Malaysian Department of Environment. Comparisons with established assays, using IC₅₀ values and confidence intervals, confirmed the superior sensitivity of the developed method. Hierarchical clustering identified patterns of enzyme sensitivity, with assays grouped by IC₅₀ intervals. Isolate 34XW was an outlier with exceptional sensitivity. K-Means clustering grouped assays into sensitivity tiers, with the clustering of the molybdenum-reducing enzyme from the bacterial isolate 34XW into a unique cluster due to the level of its sensitivity. Juru industrial estate water samples tested using the assay revealed its capability in detecting low concentrations of mercury. These findings underscore the assay’s utility in detecting elevated mercury concentrations in environmental samples and its broader implications for environmental monitoring and biochemical applications. As a preliminary screening tool for heavy metal monitoring on a large scale, the assay is quick and easy to use.
first_indexed 2025-11-15T14:36:46Z
format Article
id upm-118193
institution Universiti Putra Malaysia
institution_category Local University
language English
last_indexed 2025-11-15T14:36:46Z
publishDate 2024
publisher Hibiscus Publisher
recordtype eprints
repository_type Digital Repository
spelling upm-1181932025-06-26T09:11:47Z http://psasir.upm.edu.my/id/eprint/118193/ Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay Uba, Garba Halmi, Mohd Izuan Effendi Shukor, Mohd Yunus Due to rapid industrialization coupled with indiscriminate release of pollutants, the number of polluted rivers in Malaysia has been steadily increasing over the years. Regular monitoring of contaminants, particularly heavy metals, is not feasible due to the steep cost of instrumental monitoring alone. In this study, a rapid inhibitive enzyme assay using the molybdenum-reducing enzyme from the bacterial isolate 34XW was developed for monitoring mercury. The Mo-reducing enzyme from this bacterium was very sensitive to mercury, with an IC₅₀ confidence interval of 0.0025–0.0029. The inhibition model followed a log(inhibitor) vs. response with variable slope, enabling detection of mercury at the Maximum Permissible Limit (MPL) set by the Malaysian Department of Environment. Comparisons with established assays, using IC₅₀ values and confidence intervals, confirmed the superior sensitivity of the developed method. Hierarchical clustering identified patterns of enzyme sensitivity, with assays grouped by IC₅₀ intervals. Isolate 34XW was an outlier with exceptional sensitivity. K-Means clustering grouped assays into sensitivity tiers, with the clustering of the molybdenum-reducing enzyme from the bacterial isolate 34XW into a unique cluster due to the level of its sensitivity. Juru industrial estate water samples tested using the assay revealed its capability in detecting low concentrations of mercury. These findings underscore the assay’s utility in detecting elevated mercury concentrations in environmental samples and its broader implications for environmental monitoring and biochemical applications. As a preliminary screening tool for heavy metal monitoring on a large scale, the assay is quick and easy to use. Hibiscus Publisher 2024-07-31 Article PeerReviewed text en cc_by_4 http://psasir.upm.edu.my/id/eprint/118193/1/118193.pdf Uba, Garba and Halmi, Mohd Izuan Effendi and Shukor, Mohd Yunus (2024) Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay. Journal of Environmental Microbiology and Toxicology, 12 (1). pp. 7-13. ISSN 2289-5906 https://journal.hibiscuspublisher.com/index.php/JEMAT/article/view/999 10.54987/jemat.v12i1.999
spellingShingle Uba, Garba
Halmi, Mohd Izuan Effendi
Shukor, Mohd Yunus
Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay
title Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay
title_full Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay
title_fullStr Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay
title_full_unstemmed Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay
title_short Biomonitoring mercury pollution in Juru industrial estate using a rapid inhibitive enzyme assay
title_sort biomonitoring mercury pollution in juru industrial estate using a rapid inhibitive enzyme assay
url http://psasir.upm.edu.my/id/eprint/118193/
http://psasir.upm.edu.my/id/eprint/118193/
http://psasir.upm.edu.my/id/eprint/118193/
http://psasir.upm.edu.my/id/eprint/118193/1/118193.pdf