Stability of PRESAGE® dosimeter for end-to-end radiotherapy dosimetry audit and dose delivery
The stability of commercially available PRESAGE® was evaluated for use in complex radiotherapy dose delivery and audit. The dose-response of PRESAGE® under room temperature, low temperature and exposure to visible light was investigated. The photon energy and dose rate dependence of the PRESAGE® wer...
| Main Authors: | Mohyedin, Muhammad Zamir, Zin, Hafiz Mohd, Ung, Ngie Min, Bradley, David A., Abdul Rahman, Ahmad Taufek |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Elsevier Ltd
2025
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/117723/ http://psasir.upm.edu.my/id/eprint/117723/1/117723.pdf |
Similar Items
Dosimetric characterisation of the nanodot optically stimulated luminescent dosimeter for use in national electron beam dosimetry audit services for radiotherapy facilities
by: Mohd Noor, Noramaliza, et al.
Published: (2024)
by: Mohd Noor, Noramaliza, et al.
Published: (2024)
Investigation of thermoluminescence dosimetry characteristics of ge-doped optical fibres and photonic cystal fibre for postal dosimetry audit of radiotherapy photon and electron beams
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
by: M. Noor, Noramaliza, et al.
Published: (2017)
by: M. Noor, Noramaliza, et al.
Published: (2017)
Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2014)
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2014)
Treatment planning system dose verification for MLC-shaped photon beams in postal radiotherapy dosimetry audit: a single-centre pilot study
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2025)
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2025)
Investigation of thermoluminescene dosimetric characteristics of Ge-doped optical fibres and photonic crystal fibre for postal dosimetry audit of radiotherapy photon and electron beams.
by: Mohd. Noor, Noramaliza, et al.
by: Mohd. Noor, Noramaliza, et al.
Radiotherapy dosimetry and the thermoluminescence characteristics of Ge-doped fibres of differing germanium dopant concentration and outer diameter
by: Mohd Noor, Noramaliza, et al.
Published: (2016)
by: Mohd Noor, Noramaliza, et al.
Published: (2016)
Tailored Ge-doped fibres for passive electron radiotherapy dosimetry
by: Siti Nurasiah, M. N, et al.
Published: (2020)
by: Siti Nurasiah, M. N, et al.
Published: (2020)
Dosimetry audit for megavoltage photon beams applied in non-reference conditions
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2022)
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2022)
Characterization of Ge-doped optical fibres for MV radiotherapy dosimetry
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
by: Mohd Noor, Noramaliza, et al.
Published: (2014)
Low dose and low dose rate radioluminescence dosimetry
by: Bradley, D.A. *, et al.
Published: (2023)
by: Bradley, D.A. *, et al.
Published: (2023)
Collapsed photonic crystal fibre thermoluminescence dosimetry for external beam radiotherapy
by: Begum, M., et al.
Published: (2023)
by: Begum, M., et al.
Published: (2023)
Fabrication of a Reuseable Plastic
Based X-ray Dosimeter for
Radiotherapy
by: Tariq, Iqbal
Published: (2016)
by: Tariq, Iqbal
Published: (2016)
Raman study of lower toxicity polymer gel for radiotherapy dosimetry
by: Adenan, Mohd Zulfadli, et al.
Published: (2014)
by: Adenan, Mohd Zulfadli, et al.
Published: (2014)
Diode Dosimetric
Characterisations And Assessments
For In-Vivo Dosimetry In
Radiotherapy Treatment
by: Marzuki, Rahmatfadli
Published: (2019)
by: Marzuki, Rahmatfadli
Published: (2019)
Dose verification procedures in radiotherapy
by: Zakaria, Ahmad, et al.
Published: (1999)
by: Zakaria, Ahmad, et al.
Published: (1999)
Dosimetry and optimisation in high dose fluoroscopic and fluorographic procedures
by: Morrell, Rachel Elizabeth
Published: (2006)
by: Morrell, Rachel Elizabeth
Published: (2006)
Characterization of amorphous thermoluminescence dosimeters for patient dose measurement in X-ray diagnostic procedures
by: Ramli, N. N. H., et al.
Published: (2015)
by: Ramli, N. N. H., et al.
Published: (2015)
A systematic review: dosimetric characteristic of optically stimulated luminecence (osl) dosimeter with photon beam in radiotherapy
by: Zolkifli, Muhammad Firdaus
Published: (2020)
by: Zolkifli, Muhammad Firdaus
Published: (2020)
Presage, context, process and product: influencing variables in literature instruction in an ESL context
by: Fauziah Ahmad,
Published: (2008)
by: Fauziah Ahmad,
Published: (2008)
Radiation dose homogeneity and critical organs in radiotherapy treatment of prostate cancer
by: Khairi, Y., et al.
Published: (2021)
by: Khairi, Y., et al.
Published: (2021)
Use of fabricated germanium-doped optical fibres for radiotherapy postal dose audit of megavoltage photon beams under non-reference conditions in selected Malaysian radiotherapy facilities
by: Ahmad Fadzil, Muhammad Safwan
Published: (2020)
by: Ahmad Fadzil, Muhammad Safwan
Published: (2020)
End-user delivery methods in information skills training
by: Abdul Razak, Sakinah, et al.
Published: (2011)
by: Abdul Razak, Sakinah, et al.
Published: (2011)
Iron oxide nanoparticles as radiobiological dose enhancer for radiotherapy
by: Lazim, Rosmazihana Mat
Published: (2016)
by: Lazim, Rosmazihana Mat
Published: (2016)
Post-Mastectomy Radiotherapy Involving Supraclavical Nodes – Matchline Dose, Tumour Dose And Organs At Risk Dose
by: Alzoubi, Ahmad Saleem Salem
Published: (2009)
by: Alzoubi, Ahmad Saleem Salem
Published: (2009)
Dosimetric characteristics of fabricated ge-doped silica optical fibres for small field radiation dosimetry in radiotherapy
by: Lam, Siok Ee
Published: (2019)
by: Lam, Siok Ee
Published: (2019)
End-to-end audiovisual speech recognition
by: Petridis, Stavros, et al.
Published: (2018)
by: Petridis, Stavros, et al.
Published: (2018)
End-to-end object detection with transformers
by: Lai, Eddy Thin Jun
Published: (2024)
by: Lai, Eddy Thin Jun
Published: (2024)
Anthropomorphic phantom organ dose assessment using optically stimulated luminescence dosimeters unified in multi-detector computed tomography
by: Omar, R.S., et al.
Published: (2022)
by: Omar, R.S., et al.
Published: (2022)
A novel case-based reasoning approach to radiotherapy dose planning
by: Mishra, Nishikant
Published: (2012)
by: Mishra, Nishikant
Published: (2012)
Thermoluminescence properties of nanostructured calcium borate as a sensitive radiation dosimeter for high radiation doses
by: Haghiri, Maryam Erfani, et al.
Published: (2014)
by: Haghiri, Maryam Erfani, et al.
Published: (2014)
Synthesis, Characterization And Evaluation Of Zinc Doped MgB4O7 Based Glass Thermoluminescence Dosimeter For Radiotherapy And Industrial Applications
by: Bakhsh, Muhammad
Published: (2018)
by: Bakhsh, Muhammad
Published: (2018)
The end of the world
Published: (2010)
Published: (2010)
The end of confrontation
by: Mazlan Nordin,
Published: (2005)
by: Mazlan Nordin,
Published: (2005)
Beginning of the end?
by: Abd Razak, Dzulkifli
Published: (2009)
by: Abd Razak, Dzulkifli
Published: (2009)
An end in sight
by: Menon, Sandhya
Published: (2021)
by: Menon, Sandhya
Published: (2021)
Characterisation and application of carbon doped aluminium oxide optically stimulated luminescence dosimeter in megavoltage photon beams for radiotherapy / Fasihah Hanum Md Yusof
by: Fasihah Hanum , Md Yusof
Published: (2016)
by: Fasihah Hanum , Md Yusof
Published: (2016)
Development Of Undoped, Doped And Codoped Boron Silicate Composite As Thermoluminescent Dosimeters For Medium And High Dose Levels
by: Noori Hassan, Bahra Mohammed
Published: (2017)
by: Noori Hassan, Bahra Mohammed
Published: (2017)
Estimation of entrance skin dose (ESD) and exit dose (ED) in abdominal radiography using nanoDot optically stimulated luminescence dosimeter (OSLD)
by: Sayed, Inayatullah Shah, et al.
Published: (2019)
by: Sayed, Inayatullah Shah, et al.
Published: (2019)
Effectiveness of Al2O3: C OSL dosimeter towards entrance surface dose measurement in common X-ray diagnostics
by: Musa, Yahaya, et al.
Published: (2019)
by: Musa, Yahaya, et al.
Published: (2019)
Similar Items
-
Dosimetric characterisation of the nanodot optically stimulated luminescent dosimeter for use in national electron beam dosimetry audit services for radiotherapy facilities
by: Mohd Noor, Noramaliza, et al.
Published: (2024) -
Investigation of thermoluminescence dosimetry characteristics of ge-doped optical fibres and photonic cystal fibre for postal dosimetry audit of radiotherapy photon and electron beams
by: Mohd Noor, Noramaliza, et al.
Published: (2014) -
Dosimetry audits and intercomparisons in radiotherapy: a Malaysian profile
by: M. Noor, Noramaliza, et al.
Published: (2017) -
Dosimetric characteristics of fabricated silica fibre for postal radiotherapy dose audits
by: Ahmad Fadzil, Muhammad Safwan, et al.
Published: (2014) -
Treatment planning system dose verification for MLC-shaped photon beams in postal radiotherapy dosimetry audit: a single-centre pilot study
by: Muhammad Safwan Ahmad Fadzil,, et al.
Published: (2025)