Structural deformation and displacement of a disc winding due to standard switching impulse voltage via finite element method
Switching operations in a power system network can lead to transient overvoltage in the high voltage (HV) winding of distribution transformers that causes high-stress build-up. This paper presents the relationship between electromagnetic force due to a standard switching impulse (SSI) and mechanical...
| Main Authors: | Md Yasid, Nurul Farahwahida, Azis, Norhafiz, Jasni, Jasronita, Mohd Yousof, Mohd Fairouz, Talib, Mohd Aizam, Murthy, Avinash Srikanta |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Universiti Putra Malaysia Press
2024
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/112859/ http://psasir.upm.edu.my/id/eprint/112859/1/112859.pdf |
Similar Items
Electromagnetic force distribution computations due to switching surge in disc-type winding
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2023)
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2023)
Effect of shield placement for transient voltage mitigation due to switching surges in a 33/11 kV transformer windings
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
Investigation of the impact of a standard lightning impulse on the structure of an 11/0.415 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2022)
by: Murthy, Avinash Srikanta, et al.
Published: (2022)
Frequency responses of transformer winding deformations based on finite element modeling under transient overvoltage impulses
by: Murthy, Avinash Srikanta
Published: (2020)
by: Murthy, Avinash Srikanta
Published: (2020)
Investigation on the resonant oscillations in an 11 kV distribution transformer under standard and chopped lightning impulse overvoltages with different shield placement configurations
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Extraction of winding parameters for 33/11 kV, 30 MVA transformer based on finite element method for frequency response modelling
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Investigation on the transient voltage in a 11 kV transformer under lightning surges
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Analysis on the torque characteristics due to outer rotor displacement in the double rotor switched reluctance machine
by: Aravind, C. V., et al.
Published: (2013)
by: Aravind, C. V., et al.
Published: (2013)
Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
The influence of cavity size and location within insulation paper on the Partial Discharge activities
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
Influence of electrode geometry on the lightning impulse breakdown voltage of palm oil
by: Thien, Yee Von, et al.
Published: (2018)
by: Thien, Yee Von, et al.
Published: (2018)
The evaluation of shear deformation for contact analysis with large displacement
by: Nizam, Z. M., et al.
Published: (2018)
by: Nizam, Z. M., et al.
Published: (2018)
Classification of fault and stray gassing in transformer by using duval pentagon and machine learning algorithms
by: Haw, Jia Yong, et al.
Published: (2022)
by: Haw, Jia Yong, et al.
Published: (2022)
Disc-loaded monopole array for switched beam control
by: Kamarudin, Muhammad Ramlee, et al.
Published: (2002)
by: Kamarudin, Muhammad Ramlee, et al.
Published: (2002)
MEMS optical switch based on fiber displacement
by: Leow, C. W., et al.
Published: (2006)
by: Leow, C. W., et al.
Published: (2006)
Switching transients due to a power factor correction capacitor bank in LV power system and their comparison with lightning impulses
by: Hamad, Salih Gwami Mohammed, et al.
Published: (2019)
by: Hamad, Salih Gwami Mohammed, et al.
Published: (2019)
Effects of RTV coating on the electrical performance of polymer insulator under lightning impulse voltage condition
by: Jamaludin, Farah Adilah, et al.
Published: (2017)
by: Jamaludin, Farah Adilah, et al.
Published: (2017)
Pre-breakdown streamer propagation and breakdown characteristics of refined bleached and deodorized palm oil under lightning impulse voltage
by: Thien, Yee Von, et al.
Published: (2018)
by: Thien, Yee Von, et al.
Published: (2018)
Design and characteristics of large displacement
optical fiber switch
by: Bhuiyan, Moinul, et al.
Published: (2005)
by: Bhuiyan, Moinul, et al.
Published: (2005)
A study on the lightning impulse breakdown voltages of palm oil and coconut oil by different methods
by: Thien, Yee Von, et al.
Published: (2015)
by: Thien, Yee Von, et al.
Published: (2015)
Stability and control of switched systems with impulsive effects
by: Xu, Honglei
Published: (2009)
by: Xu, Honglei
Published: (2009)
Hybrid impulsive control for switched singular systems
by: Shi, S., et al.
Published: (2011)
by: Shi, S., et al.
Published: (2011)
Assessment of transformer health index using different model
by: Jasni, Jasronita, et al.
Published: (2017)
by: Jasni, Jasronita, et al.
Published: (2017)
Effect of RTV coating material on electric field distribution and voltage profiles on polymer insulator under lightning impulse
by: Jamaludin, Farah Adilah, et al.
Published: (2018)
by: Jamaludin, Farah Adilah, et al.
Published: (2018)
Improved Switching-Basedmedian Filter
For Impulse Noise Removal
by: Teoh, Sin Hoong
Published: (2013)
by: Teoh, Sin Hoong
Published: (2013)
Development of TNB distribution network risk based asset replacement policy and guideline for medium voltage primary equipment
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
Deformation of wood in compression due to moisture content changes
by: Chew, Meng Yew
Published: (2006)
by: Chew, Meng Yew
Published: (2006)
Health index as a tool for transformers asset management
by: Azmi, Akmalina, et al.
Published: (2015)
by: Azmi, Akmalina, et al.
Published: (2015)
Partial discharge in medium and high voltage electrical devices
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
Understanding online frequency response signatures for transformer winding deformation: Axial displacement simulation
by: Zhao, Z., et al.
Published: (2016)
by: Zhao, Z., et al.
Published: (2016)
Optimal control of impulsive switched systems with minimum subsystem durations
by: Blanchard, E., et al.
Published: (2013)
by: Blanchard, E., et al.
Published: (2013)
Optimal piecewise state feedback control for impulsive switched systems
by: Li, R., et al.
Published: (2008)
by: Li, R., et al.
Published: (2008)
Necessary and sufficient conditions for stability of impulsive switched linear systems
by: Xu, H., et al.
Published: (2011)
by: Xu, H., et al.
Published: (2011)
Robust stabilization of uncertain impulsive switched systems with delayed control
by: Xu, Honglei, et al.
Published: (2008)
by: Xu, Honglei, et al.
Published: (2008)
Loss-of-life analyses based on modified arrhenius and relative aging rate for non-thermally upgraded paper in oil-immersed transformer
by: Saleh, Najiyah, et al.
Published: (2024)
by: Saleh, Najiyah, et al.
Published: (2024)
Paper lifetime mathematical modelling based on multi pre-exponential factors for oil-immersed transformer
by: Saleh, Najiyah, et al.
Published: (2022)
by: Saleh, Najiyah, et al.
Published: (2022)
CPW-Fed disc-loaded monopole array antenna with integrated PIN diode switches
by: Kamarudin, Muhammad Ramlee, et al.
Published: (2007)
by: Kamarudin, Muhammad Ramlee, et al.
Published: (2007)
Similar Items
-
Electromagnetic force distribution computations due to switching surge in disc-type winding
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2023) -
Effect of shield placement for transient voltage mitigation due to switching surges in a 33/11 kV transformer windings
by: Murthy, Avinash Srikanta, et al.
Published: (2020) -
Investigation of the impact of a standard lightning impulse on the structure of an 11/0.415 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2022) -
Frequency responses of transformer winding deformations based on finite element modeling under transient overvoltage impulses
by: Murthy, Avinash Srikanta
Published: (2020) -
Investigation on the resonant oscillations in an 11 kV distribution transformer under standard and chopped lightning impulse overvoltages with different shield placement configurations
by: Murthy, Avinash Srikanta, et al.
Published: (2019)