Electromagnetic force distribution computations due to switching surge in disc-type winding
This manuscript discusses the computation of electromagnetic forces on a disc-type winding due to a standard switching impulse (SSI). First, the resistances, inductances and capacitances (RLC) of a 30 MVA, 33/11 kV disc-type distribution transformer were estimated to obtain the winding equivalent ci...
| Main Authors: | Md Yasid, Nurul Farahwahida, Azis, Norhafiz, Mohd Yousof, Mohd Fairouz, Jasni, Jasronita, Talib, Mohd Aizam, Murthy, Avinash Srikanta |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Institute of Advanced Engineering and Science
2023
|
| Online Access: | http://psasir.upm.edu.my/id/eprint/107645/ http://psasir.upm.edu.my/id/eprint/107645/1/29781-61899-1-PB.pdf |
Similar Items
Structural deformation and displacement of a disc winding due to standard switching impulse voltage via finite element method
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2024)
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2024)
Effect of shield placement for transient voltage mitigation due to switching surges in a 33/11 kV transformer windings
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
Investigation on the transient voltage in a 11 kV transformer under lightning surges
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Extraction of winding parameters for 33/11 kV, 30 MVA transformer based on finite element method for frequency response modelling
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
by: Murthy, Avinash Srikanta, et al.
Published: (2020)
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
by: Murthy, Avinash Srikanta, et al.
Published: (2018)
Investigation of the impact of a standard lightning impulse on the structure of an 11/0.415 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2022)
by: Murthy, Avinash Srikanta, et al.
Published: (2022)
Investigation on the resonant oscillations in an 11 kV distribution transformer under standard and chopped lightning impulse overvoltages with different shield placement configurations
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
Investigation on the resonant oscillations in an 11kV distribution transformer under standard and chopped lightning impulse overvoltages with different configurations of shield placements
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
by: Murthy, Avinash Srikanta, et al.
Published: (2019)
Frequency responses of transformer winding deformations based on finite element modeling under transient overvoltage impulses
by: Murthy, Avinash Srikanta
Published: (2020)
by: Murthy, Avinash Srikanta
Published: (2020)
The effect of electromagnetic fields due to HV line on the parallel pipeline
by: Chia, Soon Chai, et al.
Published: (2014)
by: Chia, Soon Chai, et al.
Published: (2014)
Vibration Analysis Of The Chenderoh Dam Structure Due To The Effects Of Water Spilling And Surging
by: Ghazali, Mohamad Hazwan Mohd
Published: (2019)
by: Ghazali, Mohamad Hazwan Mohd
Published: (2019)
Effect of the non-standard lightning current and waveshape on lightning surge analysis
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2008)
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2008)
The importance of corona effect in lightning surge propagation studies
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2008)
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2008)
Examination of the partial discharge behaviour within a spherical cavity in insulation paper of transformer
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
The influence of cavity size and location within insulation paper on the Partial Discharge activities
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
by: Roslan, Muhammad Hakirin, et al.
Published: (2023)
Surge protective device for low voltage equipment.
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2011)
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2011)
Classification of fault and stray gassing in transformer by using duval pentagon and machine learning algorithms
by: Haw, Jia Yong, et al.
Published: (2022)
by: Haw, Jia Yong, et al.
Published: (2022)
Disc-loaded monopole array for switched beam control
by: Kamarudin, Muhammad Ramlee, et al.
Published: (2002)
by: Kamarudin, Muhammad Ramlee, et al.
Published: (2002)
Lightning surge on the DC and AC side of solar PV system
by: Zaini, Nur Hazirah, et al.
Published: (2019)
by: Zaini, Nur Hazirah, et al.
Published: (2019)
Impact of lightning surge on surge arrester placement in high voltage substation
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2008)
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2008)
Experience and long term performance of 132kV overhead lines gapless-type surge arrester
by: Mohamed Rawi, Iryani, et al.
Published: (2014)
by: Mohamed Rawi, Iryani, et al.
Published: (2014)
Protection of naval systems against electromagnetic effects due to lightning
by: Gomes, Chandima, et al.
Published: (2011)
by: Gomes, Chandima, et al.
Published: (2011)
The characteristic of frequency response on winding faults and configurations of transformer
by: Md. Yasid, Nurul Farahwahida
Published: (2019)
by: Md. Yasid, Nurul Farahwahida
Published: (2019)
Lightning surge analysis on a large scale grid-connected solar photovoltaic system
by: Zaini, Nur Hazirah, et al.
Published: (2017)
by: Zaini, Nur Hazirah, et al.
Published: (2017)
On the effect of surge protection devices (SPDs) placement for grid-connected solar PV farm
by: Zaini, Nur Hazirah, et al.
Published: (2018)
by: Zaini, Nur Hazirah, et al.
Published: (2018)
Assessment of transformer health index using different model
by: Jasni, Jasronita, et al.
Published: (2017)
by: Jasni, Jasronita, et al.
Published: (2017)
Considering on the ground reflection effect on the electromagnetic fields due to lightning channel
by: Izadi, Mahdi, et al.
Published: (2013)
by: Izadi, Mahdi, et al.
Published: (2013)
Development of TNB distribution network risk based asset replacement policy and guideline for medium voltage primary equipment
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
Frequency response of transformer winding to investigate the influence of RLC
by: Al-Ameri, S., et al.
Published: (2019)
by: Al-Ameri, S., et al.
Published: (2019)
Comparative analysis of ACSR and ACCC conductors on corona effect for lightning surge studies
by: Mohd Nawi, Zawati, et al.
Published: (2019)
by: Mohd Nawi, Zawati, et al.
Published: (2019)
Surge and rotating stall
by: Idres, Moumen
Published: (2011)
by: Idres, Moumen
Published: (2011)
Rotating stall and surge
by: Idres, Moumen
Published: (2011)
by: Idres, Moumen
Published: (2011)
Evaluation of the electromagnetic fields due to lightning channel with respect to the striking angle
by: Izadi, Mahdi, et al.
Published: (2011)
by: Izadi, Mahdi, et al.
Published: (2011)
Numerical expressions in time domain for electromagnetic fields due to lightning channels.
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2011)
by: Ab Kadir, Mohd Zainal Abidin, et al.
Published: (2011)
Risk of cancer due to electromagnetic field exposure: a review
by: Mohammad Aidid, Edre, et al.
Published: (2016)
by: Mohammad Aidid, Edre, et al.
Published: (2016)
Risk of cancer due to electromagnetic field exposure: a review
by: Mohammad Aidid, Edre, et al.
Published: (2016)
by: Mohammad Aidid, Edre, et al.
Published: (2016)
Health index as a tool for transformers asset management
by: Azmi, Akmalina, et al.
Published: (2015)
by: Azmi, Akmalina, et al.
Published: (2015)
Partial discharge in medium and high voltage electrical devices
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
by: S. Balasubramaniam, Yogendra, et al.
Published: (2020)
Loss-of-life analyses based on modified arrhenius and relative aging rate for non-thermally upgraded paper in oil-immersed transformer
by: Saleh, Najiyah, et al.
Published: (2024)
by: Saleh, Najiyah, et al.
Published: (2024)
Similar Items
-
Structural deformation and displacement of a disc winding due to standard switching impulse voltage via finite element method
by: Md Yasid, Nurul Farahwahida, et al.
Published: (2024) -
Effect of shield placement for transient voltage mitigation due to switching surges in a 33/11 kV transformer windings
by: Murthy, Avinash Srikanta, et al.
Published: (2020) -
Investigation on the transient voltage in a 11 kV transformer under lightning surges
by: Murthy, Avinash Srikanta, et al.
Published: (2018) -
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
by: Murthy, Avinash Srikanta, et al.
Published: (2018) -
Extraction of winding parameters for 33/11 kV, 30 MVA transformer based on finite element method for frequency response modelling
by: Murthy, Avinash Srikanta, et al.
Published: (2020)