Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia

It has been quite a long time since the Malaysian government endorsed the Urban Storm Water Management Manual (USWMM) in 2000. Until now, there is no proper and detailed database on the non-point source contamination characteristics from various land uses in tropical regions of Malaysia. As such thi...

Full description

Bibliographic Details
Main Authors: Mamun, Abdullah Al, Idris, Azni, Sulaiman, Wan Nor Azmin, Shams, Shahriar
Format: Article
Published: EnPress 2024
Online Access:http://psasir.upm.edu.my/id/eprint/105748/
_version_ 1848864597258272768
author Mamun, Abdullah Al
Idris, Azni
Sulaiman, Wan Nor Azmin
Shams, Shahriar
author_facet Mamun, Abdullah Al
Idris, Azni
Sulaiman, Wan Nor Azmin
Shams, Shahriar
author_sort Mamun, Abdullah Al
building UPM Institutional Repository
collection Online Access
description It has been quite a long time since the Malaysian government endorsed the Urban Storm Water Management Manual (USWMM) in 2000. Until now, there is no proper and detailed database on the non-point source contamination characteristics from various land uses in tropical regions of Malaysia. As such this study was conducted to fill part of the information gap pertaining to the nature of runoff quality in the tropical regions. The combined sewer outfall of a 6.14 ha residential area in Malaysia was studied to characterise the urban runoff quality generated due to tropical rain. As the drainage outlet discharges sullage and storm runoff through the same drainage network, hourly flow pattern and contaminant concentrations were determined both for sullage and storm runoff. Basic statistical analysis was conducted to determine the mean, standard deviation and event mean concentration values for the study area, for which such data was not available. It was observed that the runoff generated from the area is polluted due to high total suspended solids (TSS), biochemical oxygen demand (BOD) and chemical oxygen demand (COD). The runoff contained more total organic carbon (TOC) than total inorganic carbon (TIC). The EMC values of BOD, COD, TSS, TOC, total Kjeldhal nitrogen, ammoniacal nitrogen and orthophosphate were 35, 168, 177, 11, 0.32, 0.54, 0.16 mg/L, respectively. The presence of heavy metals in the runoff was low. The EMC values of lead, zinc, nickel, cadmium, chromium and copper were 0.061, 0.358, 0.002, 0.002, 0.025 and 0.022 mg/L, respectively. Due to the high quantity of rainfall, a significant amount of annual contamination loading is generated from the nonpoint sources of the residential area.
first_indexed 2025-11-15T13:51:20Z
format Article
id upm-105748
institution Universiti Putra Malaysia
institution_category Local University
last_indexed 2025-11-15T13:51:20Z
publishDate 2024
publisher EnPress
recordtype eprints
repository_type Digital Repository
spelling upm-1057482024-05-31T07:48:06Z http://psasir.upm.edu.my/id/eprint/105748/ Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia Mamun, Abdullah Al Idris, Azni Sulaiman, Wan Nor Azmin Shams, Shahriar It has been quite a long time since the Malaysian government endorsed the Urban Storm Water Management Manual (USWMM) in 2000. Until now, there is no proper and detailed database on the non-point source contamination characteristics from various land uses in tropical regions of Malaysia. As such this study was conducted to fill part of the information gap pertaining to the nature of runoff quality in the tropical regions. The combined sewer outfall of a 6.14 ha residential area in Malaysia was studied to characterise the urban runoff quality generated due to tropical rain. As the drainage outlet discharges sullage and storm runoff through the same drainage network, hourly flow pattern and contaminant concentrations were determined both for sullage and storm runoff. Basic statistical analysis was conducted to determine the mean, standard deviation and event mean concentration values for the study area, for which such data was not available. It was observed that the runoff generated from the area is polluted due to high total suspended solids (TSS), biochemical oxygen demand (BOD) and chemical oxygen demand (COD). The runoff contained more total organic carbon (TOC) than total inorganic carbon (TIC). The EMC values of BOD, COD, TSS, TOC, total Kjeldhal nitrogen, ammoniacal nitrogen and orthophosphate were 35, 168, 177, 11, 0.32, 0.54, 0.16 mg/L, respectively. The presence of heavy metals in the runoff was low. The EMC values of lead, zinc, nickel, cadmium, chromium and copper were 0.061, 0.358, 0.002, 0.002, 0.025 and 0.022 mg/L, respectively. Due to the high quantity of rainfall, a significant amount of annual contamination loading is generated from the nonpoint sources of the residential area. EnPress 2024 Article PeerReviewed Mamun, Abdullah Al and Idris, Azni and Sulaiman, Wan Nor Azmin and Shams, Shahriar (2024) Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia. Applied Chemical Engineering, 7 (1). ISSN 2578-2010 https://www.scopus.com/inward/record.uri?eid=2-s2.0-85182211730&doi=10.24294%2face.v7i1.2224&partnerID=40&md5=3d36755b0017b6cac8664350d20573f2 10.59429/ace.v7i1.1530
spellingShingle Mamun, Abdullah Al
Idris, Azni
Sulaiman, Wan Nor Azmin
Shams, Shahriar
Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia
title Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia
title_full Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia
title_fullStr Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia
title_full_unstemmed Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia
title_short Characterisation of storm runoff contamination from a tropical urban residential area in Malaysia
title_sort characterisation of storm runoff contamination from a tropical urban residential area in malaysia
url http://psasir.upm.edu.my/id/eprint/105748/
http://psasir.upm.edu.my/id/eprint/105748/
http://psasir.upm.edu.my/id/eprint/105748/