Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode

<jats:p>A novel conductive Ni‐based metal–organic framework (MOF) decorated with Au nanoparticles (AuNPs; Au@Ni‐MOF) was developed and used as a drop‐cast thin‐film electrode to individually and simultaneously quantify dopamine (DA) and uric acid (UA). The Ni‐MOF composite was synthesized usin...

Full description

Bibliographic Details
Main Authors: Feng, Zhou, Lim, Hong Ngee, Ibrahim, Izwaharyanie, Endot, Nor Azam, Malek, Emilia Abdul, Gowthaman, N. S. Krishnan
Format: Article
Published: Wiley 2024
Online Access:http://psasir.upm.edu.my/id/eprint/105728/
_version_ 1848864591646294016
author Feng, Zhou
Lim, Hong Ngee
Ibrahim, Izwaharyanie
Endot, Nor Azam
Malek, Emilia Abdul
Gowthaman, N. S. Krishnan
author_facet Feng, Zhou
Lim, Hong Ngee
Ibrahim, Izwaharyanie
Endot, Nor Azam
Malek, Emilia Abdul
Gowthaman, N. S. Krishnan
author_sort Feng, Zhou
building UPM Institutional Repository
collection Online Access
description <jats:p>A novel conductive Ni‐based metal–organic framework (MOF) decorated with Au nanoparticles (AuNPs; Au@Ni‐MOF) was developed and used as a drop‐cast thin‐film electrode to individually and simultaneously quantify dopamine (DA) and uric acid (UA). The Ni‐MOF composite was synthesized using an in situ growth strategy involving the growth of [Ni<jats:sub>3</jats:sub>(BTC)<jats:sub>2</jats:sub>(H<jats:sub>2</jats:sub>O)<jats:sub>6</jats:sub>]n (BTC = 1,3,5‐benzenetricarboxylate) with coordinatively unsaturated Ni (II) sites. The Ni‐MOF powder was then mixed with a AuNP solution to produce a Au@Ni‐MOF hybrid material. The synthesized Au@Ni‐MOF hybrid material was employed as a surface modifier for a screen‐printed carbon electrode, and its efficacy for the detection of DA and UA was assessed using differential pulse voltammetry (DPV) and cyclic voltammetry. The developed sensor exhibited remarkable sensitivity, achieving low detection limits of approximately 0.027 and 0.028 μM (S/N = 3) in the simultaneous quantification of DA and UA, respectively. The sensor exhibited an extensive linear range of 0.5 μM to 1 mM, coupled with excellent sensitivities for DA and UA of 1.43 and 1.35 μA μM<jats:sup>−1</jats:sup> cm<jats:sup>−2</jats:sup>, respectively. Furthermore, the sensor performance in human serum and urine samples was successfully validated using DPV, which revealed outstanding recovery rates of 93.8–105.0% with a minimal relative standard deviation below 3%. Moreover, the synthesized Au@Ni‐MOF composite exhibited exceptional dispersion stability, high sensitivity, and remarkable selectivity, which were attributed to the well‐arranged combination of AuNPs and Ni‐MOFs, enabling its use in non‐enzymatic sensing applications targeting DA and UA.</jats:p>
first_indexed 2025-11-15T13:51:15Z
format Article
id upm-105728
institution Universiti Putra Malaysia
institution_category Local University
last_indexed 2025-11-15T13:51:15Z
publishDate 2024
publisher Wiley
recordtype eprints
repository_type Digital Repository
spelling upm-1057282024-05-30T06:31:50Z http://psasir.upm.edu.my/id/eprint/105728/ Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode Feng, Zhou Lim, Hong Ngee Ibrahim, Izwaharyanie Endot, Nor Azam Malek, Emilia Abdul Gowthaman, N. S. Krishnan <jats:p>A novel conductive Ni‐based metal–organic framework (MOF) decorated with Au nanoparticles (AuNPs; Au@Ni‐MOF) was developed and used as a drop‐cast thin‐film electrode to individually and simultaneously quantify dopamine (DA) and uric acid (UA). The Ni‐MOF composite was synthesized using an in situ growth strategy involving the growth of [Ni<jats:sub>3</jats:sub>(BTC)<jats:sub>2</jats:sub>(H<jats:sub>2</jats:sub>O)<jats:sub>6</jats:sub>]n (BTC = 1,3,5‐benzenetricarboxylate) with coordinatively unsaturated Ni (II) sites. The Ni‐MOF powder was then mixed with a AuNP solution to produce a Au@Ni‐MOF hybrid material. The synthesized Au@Ni‐MOF hybrid material was employed as a surface modifier for a screen‐printed carbon electrode, and its efficacy for the detection of DA and UA was assessed using differential pulse voltammetry (DPV) and cyclic voltammetry. The developed sensor exhibited remarkable sensitivity, achieving low detection limits of approximately 0.027 and 0.028 μM (S/N = 3) in the simultaneous quantification of DA and UA, respectively. The sensor exhibited an extensive linear range of 0.5 μM to 1 mM, coupled with excellent sensitivities for DA and UA of 1.43 and 1.35 μA μM<jats:sup>−1</jats:sup> cm<jats:sup>−2</jats:sup>, respectively. Furthermore, the sensor performance in human serum and urine samples was successfully validated using DPV, which revealed outstanding recovery rates of 93.8–105.0% with a minimal relative standard deviation below 3%. Moreover, the synthesized Au@Ni‐MOF composite exhibited exceptional dispersion stability, high sensitivity, and remarkable selectivity, which were attributed to the well‐arranged combination of AuNPs and Ni‐MOFs, enabling its use in non‐enzymatic sensing applications targeting DA and UA.</jats:p> Wiley 2024 Article PeerReviewed Feng, Zhou and Lim, Hong Ngee and Ibrahim, Izwaharyanie and Endot, Nor Azam and Malek, Emilia Abdul and Gowthaman, N. S. Krishnan (2024) Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode. Applied Organometallic Chemistry, 38 (4). art. no. 7350. ISSN 0268-2605; ESSN: 1099-0739 https://onlinelibrary.wiley.com/doi/10.1002/aoc.7350 10.1002/aoc.7350
spellingShingle Feng, Zhou
Lim, Hong Ngee
Ibrahim, Izwaharyanie
Endot, Nor Azam
Malek, Emilia Abdul
Gowthaman, N. S. Krishnan
Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode
title Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode
title_full Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode
title_fullStr Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode
title_full_unstemmed Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode
title_short Enhanced simultaneous voltammetric detection of dopamine and uric acid using Au@Ni-metal–organic framework-modified electrode
title_sort enhanced simultaneous voltammetric detection of dopamine and uric acid using au@ni-metal–organic framework-modified electrode
url http://psasir.upm.edu.my/id/eprint/105728/
http://psasir.upm.edu.my/id/eprint/105728/
http://psasir.upm.edu.my/id/eprint/105728/