Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia

Geomagnetic disturbance (GMD) arises during space weather and solar activity can result in geomagnetically induced current (GIC) flow in the grounded power transformers in the power network. This GIC may cause half-cycle saturation of transformers and lead to severe damage or blackout. To block the...

Full description

Bibliographic Details
Main Authors: Mohammed Khurshid, Zmnako, Ab Aziz, Nur Fadilah, Rhazali, Zeti Akma, Ab Kadir, Mohd Zainal Abidin
Format: Article
Published: IEEE Access 2022
Online Access:http://psasir.upm.edu.my/id/eprint/101110/
_version_ 1848863495046561792
author Mohammed Khurshid, Zmnako
Ab Aziz, Nur Fadilah
Rhazali, Zeti Akma
Ab Kadir, Mohd Zainal Abidin
author_facet Mohammed Khurshid, Zmnako
Ab Aziz, Nur Fadilah
Rhazali, Zeti Akma
Ab Kadir, Mohd Zainal Abidin
author_sort Mohammed Khurshid, Zmnako
building UPM Institutional Repository
collection Online Access
description Geomagnetic disturbance (GMD) arises during space weather and solar activity can result in geomagnetically induced current (GIC) flow in the grounded power transformers in the power network. This GIC may cause half-cycle saturation of transformers and lead to severe damage or blackout. To block the GIC flow into the power transformers, the neutral blocking devices (NBDs) based on capacitor banks are often installed in the neutral ground paths of transformers to mitigate the GIC. However, the high voltage (HV) can build up across these capacitors during ground faults and may cause a ferroresonance phenomenon in the power network. This phenomenon generates high voltages/currents in the transformer windings and results in transformer failure. This work investigates the effect of connected NBDs to the power transformers on the potential power network ferroresonance in Peninsular Malaysia. The complete analysis was carried out using the Power System Computer-Aided Design for Electromagnetic Transients including Direct Current (PSCAD/EMTDC) software. These transformers were selected in the power network due to the sensitivity of their locations to GMD events. The NBD systems were tested under different working conditions. The simulation results found that the metal oxide varistors (MOVs) arresters in NBDs fault protection mode effectively clamped ferroresonance overvoltages below the protection level under faulty conditions. Also, the results showed that GIC protection modes with 1 Ω and 3180 µF in the mitigation systems had the lowest ferroresonance overvoltages in the neutrals of the transformers under faulty conditions. Based on the results, the recommendations were provided to the local power utility which will help to improve the reliability of the power supply to the consumers.
first_indexed 2025-11-15T13:33:49Z
format Article
id upm-101110
institution Universiti Putra Malaysia
institution_category Local University
last_indexed 2025-11-15T13:33:49Z
publishDate 2022
publisher IEEE Access
recordtype eprints
repository_type Digital Repository
spelling upm-1011102023-05-23T07:43:43Z http://psasir.upm.edu.my/id/eprint/101110/ Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia Mohammed Khurshid, Zmnako Ab Aziz, Nur Fadilah Rhazali, Zeti Akma Ab Kadir, Mohd Zainal Abidin Geomagnetic disturbance (GMD) arises during space weather and solar activity can result in geomagnetically induced current (GIC) flow in the grounded power transformers in the power network. This GIC may cause half-cycle saturation of transformers and lead to severe damage or blackout. To block the GIC flow into the power transformers, the neutral blocking devices (NBDs) based on capacitor banks are often installed in the neutral ground paths of transformers to mitigate the GIC. However, the high voltage (HV) can build up across these capacitors during ground faults and may cause a ferroresonance phenomenon in the power network. This phenomenon generates high voltages/currents in the transformer windings and results in transformer failure. This work investigates the effect of connected NBDs to the power transformers on the potential power network ferroresonance in Peninsular Malaysia. The complete analysis was carried out using the Power System Computer-Aided Design for Electromagnetic Transients including Direct Current (PSCAD/EMTDC) software. These transformers were selected in the power network due to the sensitivity of their locations to GMD events. The NBD systems were tested under different working conditions. The simulation results found that the metal oxide varistors (MOVs) arresters in NBDs fault protection mode effectively clamped ferroresonance overvoltages below the protection level under faulty conditions. Also, the results showed that GIC protection modes with 1 Ω and 3180 µF in the mitigation systems had the lowest ferroresonance overvoltages in the neutrals of the transformers under faulty conditions. Based on the results, the recommendations were provided to the local power utility which will help to improve the reliability of the power supply to the consumers. IEEE Access 2022-06-20 Article PeerReviewed Mohammed Khurshid, Zmnako and Ab Aziz, Nur Fadilah and Rhazali, Zeti Akma and Ab Kadir, Mohd Zainal Abidin (2022) Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia. IEEE Access, 10. 77225 - 77238. ISSN 2169-3536 https://ieeexplore.ieee.org/document/9800710 10.1109/ACCESS.2022.3184424
spellingShingle Mohammed Khurshid, Zmnako
Ab Aziz, Nur Fadilah
Rhazali, Zeti Akma
Ab Kadir, Mohd Zainal Abidin
Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia
title Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia
title_full Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia
title_fullStr Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia
title_full_unstemmed Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia
title_short Effect of GIC neutral blocking devices (NBDs) on power network ferroresonance in Malaysia
title_sort effect of gic neutral blocking devices (nbds) on power network ferroresonance in malaysia
url http://psasir.upm.edu.my/id/eprint/101110/
http://psasir.upm.edu.my/id/eprint/101110/
http://psasir.upm.edu.my/id/eprint/101110/