Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol

Apart from the conventional compression cycle refrigeration, two other known cooling technologies throughout the last decade are thermoelectric and adsorption. Solar adsorption utilizes activated carbon-methanol as its working pair in producing cooling through desorption/adsorption processes. Solar...

Full description

Bibliographic Details
Main Author: Ngui, Jia Lin
Format: Thesis
Language:English
Published: Faculty of Engineering 2011
Subjects:
Online Access:http://ir.unimas.my/id/eprint/8053/
http://ir.unimas.my/id/eprint/8053/1/Ngui%20Jia%20Lin%20ft.pdf
_version_ 1848836288609779712
author Ngui, Jia Lin
author_facet Ngui, Jia Lin
author_sort Ngui, Jia Lin
building UNIMAS Institutional Repository
collection Online Access
description Apart from the conventional compression cycle refrigeration, two other known cooling technologies throughout the last decade are thermoelectric and adsorption. Solar adsorption utilizes activated carbon-methanol as its working pair in producing cooling through desorption/adsorption processes. Solar thermoelectric however utilizes the conversion of solar energy to electricity by means of photovoltaic cells to power up the cooler. Both systems have witnessed an increasing interest due to its quietness, long-lasting, inexpensive to maintain and environmentally benign. In this study, a combined system of both techniques was introduced, where cooling could be produced continuously and suitable for places away from the conventional grid )The adsorption system utilized few key elements such as adsorbers, a condenser, a reservoir, an evaporator and a cooler. The thermoelectric system was powered by two 80W solar photovoltaic panels and is regulated using a charge controller and a battery as a backup system. The principle aim of this study was to gather relevant data through experiments and act as basis for future studies. Results from the experiments were later used to calculate the coefficient of performance (COP). The relevancy of the results was then further proved and determined with a series of statistical studies. Results obtained showed that such system is feasible. The COP values of the overall system were 0.014 - 0.183 (adsorption), 0.126 - 0.173 (thermoelectric) and 0.003 - 0.005 (hybrid), respectively.
first_indexed 2025-11-15T06:21:23Z
format Thesis
id unimas-8053
institution Universiti Malaysia Sarawak
institution_category Local University
language English
last_indexed 2025-11-15T06:21:23Z
publishDate 2011
publisher Faculty of Engineering
recordtype eprints
repository_type Digital Repository
spelling unimas-80532023-05-26T03:07:52Z http://ir.unimas.my/id/eprint/8053/ Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol Ngui, Jia Lin QC Physics Apart from the conventional compression cycle refrigeration, two other known cooling technologies throughout the last decade are thermoelectric and adsorption. Solar adsorption utilizes activated carbon-methanol as its working pair in producing cooling through desorption/adsorption processes. Solar thermoelectric however utilizes the conversion of solar energy to electricity by means of photovoltaic cells to power up the cooler. Both systems have witnessed an increasing interest due to its quietness, long-lasting, inexpensive to maintain and environmentally benign. In this study, a combined system of both techniques was introduced, where cooling could be produced continuously and suitable for places away from the conventional grid )The adsorption system utilized few key elements such as adsorbers, a condenser, a reservoir, an evaporator and a cooler. The thermoelectric system was powered by two 80W solar photovoltaic panels and is regulated using a charge controller and a battery as a backup system. The principle aim of this study was to gather relevant data through experiments and act as basis for future studies. Results from the experiments were later used to calculate the coefficient of performance (COP). The relevancy of the results was then further proved and determined with a series of statistical studies. Results obtained showed that such system is feasible. The COP values of the overall system were 0.014 - 0.183 (adsorption), 0.126 - 0.173 (thermoelectric) and 0.003 - 0.005 (hybrid), respectively. Faculty of Engineering 2011 Thesis NonPeerReviewed text en http://ir.unimas.my/id/eprint/8053/1/Ngui%20Jia%20Lin%20ft.pdf Ngui, Jia Lin (2011) Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol. Masters thesis, Universiti Malaysia Sarawak (UNIMAS).
spellingShingle QC Physics
Ngui, Jia Lin
Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol
title Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol
title_full Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol
title_fullStr Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol
title_full_unstemmed Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol
title_short Performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol
title_sort performance investigation of a solar thermoelectric-adsorption cooling system using activated carbon-methanol
topic QC Physics
url http://ir.unimas.my/id/eprint/8053/
http://ir.unimas.my/id/eprint/8053/1/Ngui%20Jia%20Lin%20ft.pdf