Investigation of earth tube system application in low income building in Kuching, Sarawak

Modern residential building in Malaysia particularly in Sarawak rarely consider the ground as a source of heat sink to cool down the building. This is probably due to the lack of information on surveyed ground temperature and energy modelling of such building. A typical low income residential buildi...

Full description

Bibliographic Details
Main Authors: Imran, Muhammad Syukri, Azhaili, Baharun, Siti Halipah, Ibrahim, Wan Azlan, Wan Zainal Abidin
Format: Article
Language:English
Published: Taylor's University 2017
Subjects:
Online Access:http://ir.unimas.my/id/eprint/17831/
http://ir.unimas.my/id/eprint/17831/1/INVESTIGATION%20OF%20EARTH%20TUBE%20SYSTEM%20APPLICATION%20%28abstract%29.pdf
_version_ 1848838378351493120
author Imran, Muhammad Syukri
Azhaili, Baharun
Siti Halipah, Ibrahim
Wan Azlan, Wan Zainal Abidin
author_facet Imran, Muhammad Syukri
Azhaili, Baharun
Siti Halipah, Ibrahim
Wan Azlan, Wan Zainal Abidin
author_sort Imran, Muhammad Syukri
building UNIMAS Institutional Repository
collection Online Access
description Modern residential building in Malaysia particularly in Sarawak rarely consider the ground as a source of heat sink to cool down the building. This is probably due to the lack of information on surveyed ground temperature and energy modelling of such building. A typical low income residential building in Sarawak with earth tube was modelled in Energy Plus to determine the effect of earth tube to passively cool the building in Sarawak. From the simulation result, the indoor air temperature of the east facing zone of the building could be lowered from 33°C to 29.5°C. A further drop of about 0.6°C could be achieved if the room volume served by the earth tube is reduced. The PMV of the building were greatly reduced from 3 to 1.5 on a thermal sensation scale. The operative temperature is within 80% acceptability limits of 30.3°C operative temperature as per ASHRAE Standard 55 for naturally conditioned spaces. © School of Engineering, Taylor’s University.
first_indexed 2025-11-15T06:54:36Z
format Article
id unimas-17831
institution Universiti Malaysia Sarawak
institution_category Local University
language English
last_indexed 2025-11-15T06:54:36Z
publishDate 2017
publisher Taylor's University
recordtype eprints
repository_type Digital Repository
spelling unimas-178312017-10-03T01:33:33Z http://ir.unimas.my/id/eprint/17831/ Investigation of earth tube system application in low income building in Kuching, Sarawak Imran, Muhammad Syukri Azhaili, Baharun Siti Halipah, Ibrahim Wan Azlan, Wan Zainal Abidin TA Engineering (General). Civil engineering (General) Modern residential building in Malaysia particularly in Sarawak rarely consider the ground as a source of heat sink to cool down the building. This is probably due to the lack of information on surveyed ground temperature and energy modelling of such building. A typical low income residential building in Sarawak with earth tube was modelled in Energy Plus to determine the effect of earth tube to passively cool the building in Sarawak. From the simulation result, the indoor air temperature of the east facing zone of the building could be lowered from 33°C to 29.5°C. A further drop of about 0.6°C could be achieved if the room volume served by the earth tube is reduced. The PMV of the building were greatly reduced from 3 to 1.5 on a thermal sensation scale. The operative temperature is within 80% acceptability limits of 30.3°C operative temperature as per ASHRAE Standard 55 for naturally conditioned spaces. © School of Engineering, Taylor’s University. Taylor's University 2017-06 Article PeerReviewed text en http://ir.unimas.my/id/eprint/17831/1/INVESTIGATION%20OF%20EARTH%20TUBE%20SYSTEM%20APPLICATION%20%28abstract%29.pdf Imran, Muhammad Syukri and Azhaili, Baharun and Siti Halipah, Ibrahim and Wan Azlan, Wan Zainal Abidin (2017) Investigation of earth tube system application in low income building in Kuching, Sarawak. Journal of Engineering Science and Technology, 12 (6). pp. 1433-1445. ISSN 18234690 https://www.researchgate.net/publication/304162794
spellingShingle TA Engineering (General). Civil engineering (General)
Imran, Muhammad Syukri
Azhaili, Baharun
Siti Halipah, Ibrahim
Wan Azlan, Wan Zainal Abidin
Investigation of earth tube system application in low income building in Kuching, Sarawak
title Investigation of earth tube system application in low income building in Kuching, Sarawak
title_full Investigation of earth tube system application in low income building in Kuching, Sarawak
title_fullStr Investigation of earth tube system application in low income building in Kuching, Sarawak
title_full_unstemmed Investigation of earth tube system application in low income building in Kuching, Sarawak
title_short Investigation of earth tube system application in low income building in Kuching, Sarawak
title_sort investigation of earth tube system application in low income building in kuching, sarawak
topic TA Engineering (General). Civil engineering (General)
url http://ir.unimas.my/id/eprint/17831/
http://ir.unimas.my/id/eprint/17831/
http://ir.unimas.my/id/eprint/17831/1/INVESTIGATION%20OF%20EARTH%20TUBE%20SYSTEM%20APPLICATION%20%28abstract%29.pdf