Sarawak General Hospital main block building retrofit features for energy efficiency

The purpose of this study is to evaluate the energy use of the Sarawak General Hospital main medical block building and to propose a low energy measures that would satisfy the Malaysian Energy Standard MS1525 solar heat gain through building envelope (OTTV) maximum recommended value of 50W/m2. Cooli...

Full description

Bibliographic Details
Main Author: Muhammad Syukri, Imran
Format: Thesis
Language:English
Published: Universiti Malaysia Sarawak, (UNIMAS) 2011
Subjects:
Online Access:http://ir.unimas.my/id/eprint/12695/
http://ir.unimas.my/id/eprint/12695/4/Sarawak%20General%20Hospital%20main%20block%20building%20retrofit%20features%20for%20energy%20efficiency%20%28fulltext%29.pdf
_version_ 1848837252800577536
author Muhammad Syukri, Imran
author_facet Muhammad Syukri, Imran
author_sort Muhammad Syukri, Imran
building UNIMAS Institutional Repository
collection Online Access
description The purpose of this study is to evaluate the energy use of the Sarawak General Hospital main medical block building and to propose a low energy measures that would satisfy the Malaysian Energy Standard MS1525 solar heat gain through building envelope (OTTV) maximum recommended value of 50W/m2. Cooling and lighting alone constitute about 56% of energy use in the building which if energy efficiency strategies were applied to could produce a significant energy savings. A few measures wee considered which included double low e glazing, shading devices such as overhangs and fins and high reflective coatings. The potential and limitation of the measures on the cooling load of the building were assessed with the use of building energy pogram Energy Plus.
first_indexed 2025-11-15T06:36:43Z
format Thesis
id unimas-12695
institution Universiti Malaysia Sarawak
institution_category Local University
language English
last_indexed 2025-11-15T06:36:43Z
publishDate 2011
publisher Universiti Malaysia Sarawak, (UNIMAS)
recordtype eprints
repository_type Digital Repository
spelling unimas-126952025-07-02T07:54:38Z http://ir.unimas.my/id/eprint/12695/ Sarawak General Hospital main block building retrofit features for energy efficiency Muhammad Syukri, Imran HJ Public Finance HM Sociology The purpose of this study is to evaluate the energy use of the Sarawak General Hospital main medical block building and to propose a low energy measures that would satisfy the Malaysian Energy Standard MS1525 solar heat gain through building envelope (OTTV) maximum recommended value of 50W/m2. Cooling and lighting alone constitute about 56% of energy use in the building which if energy efficiency strategies were applied to could produce a significant energy savings. A few measures wee considered which included double low e glazing, shading devices such as overhangs and fins and high reflective coatings. The potential and limitation of the measures on the cooling load of the building were assessed with the use of building energy pogram Energy Plus. Universiti Malaysia Sarawak, (UNIMAS) 2011 Thesis NonPeerReviewed text en http://ir.unimas.my/id/eprint/12695/4/Sarawak%20General%20Hospital%20main%20block%20building%20retrofit%20features%20for%20energy%20efficiency%20%28fulltext%29.pdf Muhammad Syukri, Imran (2011) Sarawak General Hospital main block building retrofit features for energy efficiency. Masters thesis, Faculty of Engineering.
spellingShingle HJ Public Finance
HM Sociology
Muhammad Syukri, Imran
Sarawak General Hospital main block building retrofit features for energy efficiency
title Sarawak General Hospital main block building retrofit features for energy efficiency
title_full Sarawak General Hospital main block building retrofit features for energy efficiency
title_fullStr Sarawak General Hospital main block building retrofit features for energy efficiency
title_full_unstemmed Sarawak General Hospital main block building retrofit features for energy efficiency
title_short Sarawak General Hospital main block building retrofit features for energy efficiency
title_sort sarawak general hospital main block building retrofit features for energy efficiency
topic HJ Public Finance
HM Sociology
url http://ir.unimas.my/id/eprint/12695/
http://ir.unimas.my/id/eprint/12695/4/Sarawak%20General%20Hospital%20main%20block%20building%20retrofit%20features%20for%20energy%20efficiency%20%28fulltext%29.pdf