An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment

Legislation and assessments on air pollution in Malaysia have focused primarily on ambient air pollution. The issue of indoor air quality has been gaining much public awareness in recent years due to increasing understanding of its effects on employee's health, comfort and productivity. This is...

Full description

Bibliographic Details
Main Author: Elly Lawai, Ngalai
Format: Thesis
Language:English
English
Published: Universiti Malaysia Sarawak, (UNIMAS) 2008
Subjects:
Online Access:http://ir.unimas.my/id/eprint/10137/
http://ir.unimas.my/id/eprint/10137/2/Elly%20Lawai%20Abstract.pdf
http://ir.unimas.my/id/eprint/10137/1/Elly%20Lawai.pdf
_version_ 1848836712661254144
author Elly Lawai, Ngalai
author_facet Elly Lawai, Ngalai
author_sort Elly Lawai, Ngalai
building UNIMAS Institutional Repository
collection Online Access
description Legislation and assessments on air pollution in Malaysia have focused primarily on ambient air pollution. The issue of indoor air quality has been gaining much public awareness in recent years due to increasing understanding of its effects on employee's health, comfort and productivity. This is of particular concern and deserving more attention, considering that employees spend the majority of their time in indoor environments where they are exposed to high levels of indoor air pollutanty Three major indoor air pollutants, namely particulate matter (PM10), carbon monoxide (CO), and total volatile organic compounds (TVOCs) together with carbon dioxide (C02), humidity, and temperature were measured in ten different locations at UiTM Campus Sarawak. Results of the study show that the levels of particulate matter ranged between 7 Ilg/m3 and 35 Ilg/m3, carbon monoxide between 0.02 ppm and 0.20 ppm, and total volatile organic compounds between 0.15 ppm and 0.38 ppm. These values were low as compared to levels recorded in similar studies conducted by other researchers elsewhere. When comparisons were made against the recommended levels stated in different guidelines and standards issued by various government and environmental agencies, the pollutants levels recorded in this study were within the acceptable ranges. Carbon dioxide levels were relatively high, but still within the acceptable ranges, while humidity exceeded the recommended range at all the locations~'under study. From this study, no specific source of air pollutants was identified, however, building materials, furnishings, office equipments, and occupants' activities could have significantly contributed to the comparatively higher levels of particulate matters and carbon dioxide, and total volatile organic compounds at some of the locations.
first_indexed 2025-11-15T06:28:08Z
format Thesis
id unimas-10137
institution Universiti Malaysia Sarawak
institution_category Local University
language English
English
last_indexed 2025-11-15T06:28:08Z
publishDate 2008
publisher Universiti Malaysia Sarawak, (UNIMAS)
recordtype eprints
repository_type Digital Repository
spelling unimas-101372025-04-11T03:04:01Z http://ir.unimas.my/id/eprint/10137/ An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment Elly Lawai, Ngalai GE Environmental Sciences Legislation and assessments on air pollution in Malaysia have focused primarily on ambient air pollution. The issue of indoor air quality has been gaining much public awareness in recent years due to increasing understanding of its effects on employee's health, comfort and productivity. This is of particular concern and deserving more attention, considering that employees spend the majority of their time in indoor environments where they are exposed to high levels of indoor air pollutanty Three major indoor air pollutants, namely particulate matter (PM10), carbon monoxide (CO), and total volatile organic compounds (TVOCs) together with carbon dioxide (C02), humidity, and temperature were measured in ten different locations at UiTM Campus Sarawak. Results of the study show that the levels of particulate matter ranged between 7 Ilg/m3 and 35 Ilg/m3, carbon monoxide between 0.02 ppm and 0.20 ppm, and total volatile organic compounds between 0.15 ppm and 0.38 ppm. These values were low as compared to levels recorded in similar studies conducted by other researchers elsewhere. When comparisons were made against the recommended levels stated in different guidelines and standards issued by various government and environmental agencies, the pollutants levels recorded in this study were within the acceptable ranges. Carbon dioxide levels were relatively high, but still within the acceptable ranges, while humidity exceeded the recommended range at all the locations~'under study. From this study, no specific source of air pollutants was identified, however, building materials, furnishings, office equipments, and occupants' activities could have significantly contributed to the comparatively higher levels of particulate matters and carbon dioxide, and total volatile organic compounds at some of the locations. Universiti Malaysia Sarawak, (UNIMAS) 2008 Thesis NonPeerReviewed text en http://ir.unimas.my/id/eprint/10137/2/Elly%20Lawai%20Abstract.pdf text en http://ir.unimas.my/id/eprint/10137/1/Elly%20Lawai.pdf Elly Lawai, Ngalai (2008) An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment. Masters thesis, Universiti Malaysia Sarawak, UNIMAS.
spellingShingle GE Environmental Sciences
Elly Lawai, Ngalai
An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment
title An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment
title_full An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment
title_fullStr An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment
title_full_unstemmed An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment
title_short An assessment of PM10, Co and Tvocs in air-conditioned indoor enviroment
title_sort assessment of pm10, co and tvocs in air-conditioned indoor enviroment
topic GE Environmental Sciences
url http://ir.unimas.my/id/eprint/10137/
http://ir.unimas.my/id/eprint/10137/2/Elly%20Lawai%20Abstract.pdf
http://ir.unimas.my/id/eprint/10137/1/Elly%20Lawai.pdf