The effect of wind force on metal deck roof joint

Wind related damage had been rapidly increase in Malaysia. Previous record most of the failure occurred at roof structure system. Roof metal decking is commonly used now in roof structure system in Malaysia. Pull through failure mostly occurred due to insufficient connection. Therefore this stud...

Full description

Bibliographic Details
Main Author: Marshiela, Maedika
Format: Undergraduates Project Papers
Language:English
Published: 2014
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/9776/
http://umpir.ump.edu.my/id/eprint/9776/1/MARSHILA%20BINTI%20MAEDIKA%20%23.PDF
_version_ 1848818577569742848
author Marshiela, Maedika
author_facet Marshiela, Maedika
author_sort Marshiela, Maedika
building UMP Institutional Repository
collection Online Access
description Wind related damage had been rapidly increase in Malaysia. Previous record most of the failure occurred at roof structure system. Roof metal decking is commonly used now in roof structure system in Malaysia. Pull through failure mostly occurred due to insufficient connection. Therefore this study is conducted to investigate the potential of failure and to provide the information related to connection in roof metal decking system. From previous study it was been identify that the maximum failures load of screw connection is 0.99 kN A general metal roof deck used in Malaysia were identified and been analysed. Two different connection type were used which is screw and nail in this study. The spacing between the connection been model are 300 mm, 600 mm, 900 mm and 1200 mm. Finite Element software were used to analyse the force acting to the connection. From the result it was shown that the maximum spacing of screw connection to resist wind speed at 32.5 m/s is 1100 mm. Result also shown that by increasing the spacing distance of connection will affect the risk to failure. It can be concludes that the spacing of the connection are very important in order to resist wind storm.
first_indexed 2025-11-15T01:39:53Z
format Undergraduates Project Papers
id ump-9776
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T01:39:53Z
publishDate 2014
recordtype eprints
repository_type Digital Repository
spelling ump-97762021-07-12T02:07:40Z http://umpir.ump.edu.my/id/eprint/9776/ The effect of wind force on metal deck roof joint Marshiela, Maedika TH Building construction Wind related damage had been rapidly increase in Malaysia. Previous record most of the failure occurred at roof structure system. Roof metal decking is commonly used now in roof structure system in Malaysia. Pull through failure mostly occurred due to insufficient connection. Therefore this study is conducted to investigate the potential of failure and to provide the information related to connection in roof metal decking system. From previous study it was been identify that the maximum failures load of screw connection is 0.99 kN A general metal roof deck used in Malaysia were identified and been analysed. Two different connection type were used which is screw and nail in this study. The spacing between the connection been model are 300 mm, 600 mm, 900 mm and 1200 mm. Finite Element software were used to analyse the force acting to the connection. From the result it was shown that the maximum spacing of screw connection to resist wind speed at 32.5 m/s is 1100 mm. Result also shown that by increasing the spacing distance of connection will affect the risk to failure. It can be concludes that the spacing of the connection are very important in order to resist wind storm. 2014-07 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/9776/1/MARSHILA%20BINTI%20MAEDIKA%20%23.PDF Marshiela, Maedika (2014) The effect of wind force on metal deck roof joint. Faculty of Civil Engineering and Earth Resources, Universiti Malaysia Pahang .
spellingShingle TH Building construction
Marshiela, Maedika
The effect of wind force on metal deck roof joint
title The effect of wind force on metal deck roof joint
title_full The effect of wind force on metal deck roof joint
title_fullStr The effect of wind force on metal deck roof joint
title_full_unstemmed The effect of wind force on metal deck roof joint
title_short The effect of wind force on metal deck roof joint
title_sort effect of wind force on metal deck roof joint
topic TH Building construction
url http://umpir.ump.edu.my/id/eprint/9776/
http://umpir.ump.edu.my/id/eprint/9776/1/MARSHILA%20BINTI%20MAEDIKA%20%23.PDF