A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants

Nowadays, with advanced technology, many parents choose to monitor their baby's health using a pulse oximeter device. However, the current device can be difficult for infants, particularly for preterm babies who require continuous monitoring after being discharged from the hospital. With the ev...

Full description

Bibliographic Details
Main Authors: Muhammad Afiq Firdaus, Md Zin, Mohd Azrul Hisham, Mohd Adib
Format: Conference or Workshop Item
Language:English
Published: Springer Singapore 2024
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/44764/
http://umpir.ump.edu.my/id/eprint/44764/1/A%20preliminary%20study%20of%20heart%20rate%20SpO2.pdf
_version_ 1848827177110339584
author Muhammad Afiq Firdaus, Md Zin
Mohd Azrul Hisham, Mohd Adib
author_facet Muhammad Afiq Firdaus, Md Zin
Mohd Azrul Hisham, Mohd Adib
author_sort Muhammad Afiq Firdaus, Md Zin
building UMP Institutional Repository
collection Online Access
description Nowadays, with advanced technology, many parents choose to monitor their baby's health using a pulse oximeter device. However, the current device can be difficult for infants, particularly for preterm babies who require continuous monitoring after being discharged from the hospital. With the ever-evolving medical technology and the emphasis on non-invasive health monitoring, many parents now rely on pulse oximeter devices to keep track of their infant's health. In response to the challenges posed by existing devices, a new solution called the Preemies Car Seat Device (PreeCASE) has been introduced. This portable, non-invasive device along with a mobile application, aims to streamline monitoring of the heart rate, SpO2, and temperature for pretem infants. The PreeCASE device intergates an ESP32 microcontroller and state-of-the-art wireless network sensors to captures and relay the key parameters. It displays the data prominently on an LCD, reflecting the corresponding health levels. In addition to its monitoring capabilities, the PreeCASE device is designed to be lightweight and portable, similar to the convenience and innovation seen in artificial organ technology. This efficient and user-friendly device not only enhance the user experience but also provide a robust tool for pediatricians in Malaysia, promising a seamless transition and monitoring phase for preterm infants. This technological, advancement underscores the potential for future innovations in continuous health monitoring and care.
first_indexed 2025-11-15T03:56:34Z
format Conference or Workshop Item
id ump-44764
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:56:34Z
publishDate 2024
publisher Springer Singapore
recordtype eprints
repository_type Digital Repository
spelling ump-447642025-06-11T02:41:54Z http://umpir.ump.edu.my/id/eprint/44764/ A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants Muhammad Afiq Firdaus, Md Zin Mohd Azrul Hisham, Mohd Adib RJ Pediatrics TJ Mechanical engineering and machinery Nowadays, with advanced technology, many parents choose to monitor their baby's health using a pulse oximeter device. However, the current device can be difficult for infants, particularly for preterm babies who require continuous monitoring after being discharged from the hospital. With the ever-evolving medical technology and the emphasis on non-invasive health monitoring, many parents now rely on pulse oximeter devices to keep track of their infant's health. In response to the challenges posed by existing devices, a new solution called the Preemies Car Seat Device (PreeCASE) has been introduced. This portable, non-invasive device along with a mobile application, aims to streamline monitoring of the heart rate, SpO2, and temperature for pretem infants. The PreeCASE device intergates an ESP32 microcontroller and state-of-the-art wireless network sensors to captures and relay the key parameters. It displays the data prominently on an LCD, reflecting the corresponding health levels. In addition to its monitoring capabilities, the PreeCASE device is designed to be lightweight and portable, similar to the convenience and innovation seen in artificial organ technology. This efficient and user-friendly device not only enhance the user experience but also provide a robust tool for pediatricians in Malaysia, promising a seamless transition and monitoring phase for preterm infants. This technological, advancement underscores the potential for future innovations in continuous health monitoring and care. Springer Singapore 2024 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/44764/1/A%20preliminary%20study%20of%20heart%20rate%20SpO2.pdf Muhammad Afiq Firdaus, Md Zin and Mohd Azrul Hisham, Mohd Adib (2024) A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants. In: Lecture Notes in Bioengineering. Lecture Notes in Bioengineering; Annual Congress of the Asia-Pacific Society for Artificial Organs, APSAO 2023 , 25 - 26 September 2023 , Kuala Lumpur. 197 -204.. ISSN 2195-271X ISBN 978-981972110-8 (Published) https://doi.org/10.1007/978-981-97-1920-4_19
spellingShingle RJ Pediatrics
TJ Mechanical engineering and machinery
Muhammad Afiq Firdaus, Md Zin
Mohd Azrul Hisham, Mohd Adib
A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants
title A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants
title_full A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants
title_fullStr A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants
title_full_unstemmed A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants
title_short A preliminary study of heart rate, SpO2, and temperature on portable non-invasive preemies car seat device (PreeCASE) for monitoring preterm infants
title_sort preliminary study of heart rate, spo2, and temperature on portable non-invasive preemies car seat device (preecase) for monitoring preterm infants
topic RJ Pediatrics
TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/44764/
http://umpir.ump.edu.my/id/eprint/44764/
http://umpir.ump.edu.my/id/eprint/44764/1/A%20preliminary%20study%20of%20heart%20rate%20SpO2.pdf