Study of physiological parameters on development medical device in monitoring infant vital signs: A review
Exposure to new technology is a very effective medium in handling healthcare devices, especially for monitoring the treatment of babies. This paper provides a comprehensive review of recent developments device in monitoring infant vital signs such as heart rate, SpO2 level, and temperature of neonat...
| Main Authors: | , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
IJETAE Publishing House
2024
|
| Subjects: | |
| Online Access: | http://umpir.ump.edu.my/id/eprint/44760/ http://umpir.ump.edu.my/id/eprint/44760/1/Study%20of%20physiological%20parameters%20on%20development%20medical%20device.pdf |
| _version_ | 1848827176084832256 |
|---|---|
| author | Muhammad Afiq Firdaus, Md Zin Mohd Azrul Hisham, Mohd Adib |
| author_facet | Muhammad Afiq Firdaus, Md Zin Mohd Azrul Hisham, Mohd Adib |
| author_sort | Muhammad Afiq Firdaus, Md Zin |
| building | UMP Institutional Repository |
| collection | Online Access |
| description | Exposure to new technology is a very effective medium in handling healthcare devices, especially for monitoring the treatment of babies. This paper provides a comprehensive review of recent developments device in monitoring infant vital signs such as heart rate, SpO2 level, and temperature of neonates. The need to monitor physiological parameters is essential for ensuring the infant’s condition is stable and healthy, especially for premature babies. The technological advancements, obstacles, and possible future directions are well discussed. A comprehensive analysis of pertinent literature illustrates the details of physiological parameters used in the present devices. Integrated devices with digital health systems can enhance newborn care and reduce the risks of infant morbidity and mortality. |
| first_indexed | 2025-11-15T03:56:33Z |
| format | Article |
| id | ump-44760 |
| institution | Universiti Malaysia Pahang |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T03:56:33Z |
| publishDate | 2024 |
| publisher | IJETAE Publishing House |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | ump-447602025-06-11T01:47:09Z http://umpir.ump.edu.my/id/eprint/44760/ Study of physiological parameters on development medical device in monitoring infant vital signs: A review Muhammad Afiq Firdaus, Md Zin Mohd Azrul Hisham, Mohd Adib RJ Pediatrics T Technology (General) TJ Mechanical engineering and machinery Exposure to new technology is a very effective medium in handling healthcare devices, especially for monitoring the treatment of babies. This paper provides a comprehensive review of recent developments device in monitoring infant vital signs such as heart rate, SpO2 level, and temperature of neonates. The need to monitor physiological parameters is essential for ensuring the infant’s condition is stable and healthy, especially for premature babies. The technological advancements, obstacles, and possible future directions are well discussed. A comprehensive analysis of pertinent literature illustrates the details of physiological parameters used in the present devices. Integrated devices with digital health systems can enhance newborn care and reduce the risks of infant morbidity and mortality. IJETAE Publishing House 2024-06 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/44760/1/Study%20of%20physiological%20parameters%20on%20development%20medical%20device.pdf Muhammad Afiq Firdaus, Md Zin and Mohd Azrul Hisham, Mohd Adib (2024) Study of physiological parameters on development medical device in monitoring infant vital signs: A review. International Journal of Emerging Technology and Advanced Engineering, 14 (2). pp. 48-58. ISSN 2250–2459. (Published) https://doi.org/10.46338/ijetae0224_06 https://doi.org/10.46338/ijetae0224_06 |
| spellingShingle | RJ Pediatrics T Technology (General) TJ Mechanical engineering and machinery Muhammad Afiq Firdaus, Md Zin Mohd Azrul Hisham, Mohd Adib Study of physiological parameters on development medical device in monitoring infant vital signs: A review |
| title | Study of physiological parameters on development medical device in monitoring infant vital signs: A review |
| title_full | Study of physiological parameters on development medical device in monitoring infant vital signs: A review |
| title_fullStr | Study of physiological parameters on development medical device in monitoring infant vital signs: A review |
| title_full_unstemmed | Study of physiological parameters on development medical device in monitoring infant vital signs: A review |
| title_short | Study of physiological parameters on development medical device in monitoring infant vital signs: A review |
| title_sort | study of physiological parameters on development medical device in monitoring infant vital signs: a review |
| topic | RJ Pediatrics T Technology (General) TJ Mechanical engineering and machinery |
| url | http://umpir.ump.edu.my/id/eprint/44760/ http://umpir.ump.edu.my/id/eprint/44760/ http://umpir.ump.edu.my/id/eprint/44760/ http://umpir.ump.edu.my/id/eprint/44760/1/Study%20of%20physiological%20parameters%20on%20development%20medical%20device.pdf |