Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements

Cardiovascular disease remains the leading cause of morbidity and mortality globally, necessitating extensive research into the hemodynamics of blood flow under pathological conditions, such as atherosclerosis in carotid arteries. In vitro studies, particularly Computational Fl...

Full description

Bibliographic Details
Main Authors: A. Fahmi Huwaidi, M. Noor, Nasrul Hadi, Johari, Adi Azriff, Basri, Xu, Xiao Yun
Format: Article
Language:English
Published: Universiti Malaysia Pahang 2024
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/42891/
http://umpir.ump.edu.my/id/eprint/42891/1/Comparison%20of%20Velocity%20Profiles%20in%20Stented%20Carotid%20Artery%20Bifurcation.pdf
_version_ 1848826728134213632
author A. Fahmi Huwaidi, M. Noor
Nasrul Hadi, Johari
Adi Azriff, Basri
Xu, Xiao Yun
author_facet A. Fahmi Huwaidi, M. Noor
Nasrul Hadi, Johari
Adi Azriff, Basri
Xu, Xiao Yun
author_sort A. Fahmi Huwaidi, M. Noor
building UMP Institutional Repository
collection Online Access
description Cardiovascular disease remains the leading cause of morbidity and mortality globally, necessitating extensive research into the hemodynamics of blood flow under pathological conditions, such as atherosclerosis in carotid arteries. In vitro studies, particularly Computational Fluid Dynamics (CFD), are crucial for advancing our understanding of arterial blood flow and predicting pathological states. However, the accuracy of CFD simulations relies heavily on their validation against empirical data, such as those obtained from Particle Image Velocimetry (PIV). This study focuses on the comparative analysis of CFD predictions and PIV measurements of blood velocity vectors in a stented carotid artery bifurcation model under steady flow conditions derived from patient-specific data. The methodology involves simulating blood flow within a CFD framework and conducting PIV experiments using a blood-mimicking fluid seeded with particles in a carotid artery bifurcation phantom. The results indicate a reasonable agreement between the axial velocity vector profiles obtainedvia PIV and those predicted by CFD, with CFD predicting 10% higher than that recorded by PIV, especially in terms of recirculation areas and velocity values, despite some discrepancies in the velocity contours distribution, highlighting potential differences in how each method captures flow separation or recirculation areas. Despite some discrepancies in velocity contour distribution, which highlight potential differences in capturing flow separation or recirculation areas, the findings confirm that CFD simulations can effectively replicate the hemodynamics observed in carotid arteries and potentially other arterial segments. This study emphasizes the importance of integrating CFD simulations with experimental PIV data to validate and refine our understanding of arterial flow dynamics, significantly contributing to cardiovascular research and the development of interventions for arterial diseases.
first_indexed 2025-11-15T03:49:26Z
format Article
id ump-42891
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:49:26Z
publishDate 2024
publisher Universiti Malaysia Pahang
recordtype eprints
repository_type Digital Repository
spelling ump-428912024-11-07T06:30:30Z http://umpir.ump.edu.my/id/eprint/42891/ Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements A. Fahmi Huwaidi, M. Noor Nasrul Hadi, Johari Adi Azriff, Basri Xu, Xiao Yun R Medicine (General) TJ Mechanical engineering and machinery Cardiovascular disease remains the leading cause of morbidity and mortality globally, necessitating extensive research into the hemodynamics of blood flow under pathological conditions, such as atherosclerosis in carotid arteries. In vitro studies, particularly Computational Fluid Dynamics (CFD), are crucial for advancing our understanding of arterial blood flow and predicting pathological states. However, the accuracy of CFD simulations relies heavily on their validation against empirical data, such as those obtained from Particle Image Velocimetry (PIV). This study focuses on the comparative analysis of CFD predictions and PIV measurements of blood velocity vectors in a stented carotid artery bifurcation model under steady flow conditions derived from patient-specific data. The methodology involves simulating blood flow within a CFD framework and conducting PIV experiments using a blood-mimicking fluid seeded with particles in a carotid artery bifurcation phantom. The results indicate a reasonable agreement between the axial velocity vector profiles obtainedvia PIV and those predicted by CFD, with CFD predicting 10% higher than that recorded by PIV, especially in terms of recirculation areas and velocity values, despite some discrepancies in the velocity contours distribution, highlighting potential differences in how each method captures flow separation or recirculation areas. Despite some discrepancies in velocity contour distribution, which highlight potential differences in capturing flow separation or recirculation areas, the findings confirm that CFD simulations can effectively replicate the hemodynamics observed in carotid arteries and potentially other arterial segments. This study emphasizes the importance of integrating CFD simulations with experimental PIV data to validate and refine our understanding of arterial flow dynamics, significantly contributing to cardiovascular research and the development of interventions for arterial diseases. Universiti Malaysia Pahang 2024-06-20 Article PeerReviewed pdf en cc_by_nc_4 http://umpir.ump.edu.my/id/eprint/42891/1/Comparison%20of%20Velocity%20Profiles%20in%20Stented%20Carotid%20Artery%20Bifurcation.pdf A. Fahmi Huwaidi, M. Noor and Nasrul Hadi, Johari and Adi Azriff, Basri and Xu, Xiao Yun (2024) Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements. International Journal of Automotive and Mechanical Engineering (IJAME), 21 (2). pp. 11386-11397. ISSN 2229-8649 (Print); 2180-1606 (Online). (Published) https://doi.org/10.15282/ijame.21.2.2024.16.0879 https://doi.org/10.15282/ijame.21.2.2024.16.0879
spellingShingle R Medicine (General)
TJ Mechanical engineering and machinery
A. Fahmi Huwaidi, M. Noor
Nasrul Hadi, Johari
Adi Azriff, Basri
Xu, Xiao Yun
Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements
title Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements
title_full Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements
title_fullStr Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements
title_full_unstemmed Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements
title_short Comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements
title_sort comparison of velocity profiles in stented carotid artery bifurcation between computational fluid dynamics and particle image velocimetry measurements
topic R Medicine (General)
TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/42891/
http://umpir.ump.edu.my/id/eprint/42891/
http://umpir.ump.edu.my/id/eprint/42891/
http://umpir.ump.edu.my/id/eprint/42891/1/Comparison%20of%20Velocity%20Profiles%20in%20Stented%20Carotid%20Artery%20Bifurcation.pdf