Fault distance calculation considering sequence impedance values on the distribution network

Fault on distribution line needs to be stored as quickly as possible. It is due to fault effect to the damage of equipment and blackout. In this paper, single line to ground fault is considered in the simulation. The fault distance calculation is used an impedance-based method. The value of negative...

Full description

Bibliographic Details
Main Authors: J. Awalin, Lilik, Syahirah, Abdul Halim, Nor Azuana, Ramli
Format: Conference or Workshop Item
Language:English
English
Published: AIP Publishing 2023
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/41055/
http://umpir.ump.edu.my/id/eprint/41055/1/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/41055/2/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network.pdf
_version_ 1848826222672347136
author J. Awalin, Lilik
Syahirah, Abdul Halim
Nor Azuana, Ramli
author_facet J. Awalin, Lilik
Syahirah, Abdul Halim
Nor Azuana, Ramli
author_sort J. Awalin, Lilik
building UMP Institutional Repository
collection Online Access
description Fault on distribution line needs to be stored as quickly as possible. It is due to fault effect to the damage of equipment and blackout. In this paper, single line to ground fault is considered in the simulation. The fault distance calculation is used an impedance-based method. The value of negative and positive sequence impedance was utilized in the formulation. The various distances in each section are simulated in order to observe the accuracy of the impedance-based method. The test network was adopted from the real data from Tenaga Nasional Berhad (TNB) Malaysia. The network was installed as an underground distribution network with 19 nodes (branches and main feeder). The obtained result shows that by considering sequence impedance to the fault distance calculation, it is able to generate acceptable accuracy.
first_indexed 2025-11-15T03:41:23Z
format Conference or Workshop Item
id ump-41055
institution Universiti Malaysia Pahang
institution_category Local University
language English
English
last_indexed 2025-11-15T03:41:23Z
publishDate 2023
publisher AIP Publishing
recordtype eprints
repository_type Digital Repository
spelling ump-410552024-04-26T06:49:01Z http://umpir.ump.edu.my/id/eprint/41055/ Fault distance calculation considering sequence impedance values on the distribution network J. Awalin, Lilik Syahirah, Abdul Halim Nor Azuana, Ramli QA Mathematics TK Electrical engineering. Electronics Nuclear engineering Fault on distribution line needs to be stored as quickly as possible. It is due to fault effect to the damage of equipment and blackout. In this paper, single line to ground fault is considered in the simulation. The fault distance calculation is used an impedance-based method. The value of negative and positive sequence impedance was utilized in the formulation. The various distances in each section are simulated in order to observe the accuracy of the impedance-based method. The test network was adopted from the real data from Tenaga Nasional Berhad (TNB) Malaysia. The network was installed as an underground distribution network with 19 nodes (branches and main feeder). The obtained result shows that by considering sequence impedance to the fault distance calculation, it is able to generate acceptable accuracy. AIP Publishing 2023 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/41055/1/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network%20-%20Abstract.pdf pdf en http://umpir.ump.edu.my/id/eprint/41055/2/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network.pdf J. Awalin, Lilik and Syahirah, Abdul Halim and Nor Azuana, Ramli (2023) Fault distance calculation considering sequence impedance values on the distribution network. In: AIP Conference Proceedings. International Conference on Advanced Technology and Multidiscipline (ICATAM) 2021 , 13 - 14 October 2021 , Surabaya, Indonesia. , 2536 (030015). ISSN 0094-243X ISBN 978-0-7354-4442-3 (Published) https://doi.org/10.1063/5.0135288
spellingShingle QA Mathematics
TK Electrical engineering. Electronics Nuclear engineering
J. Awalin, Lilik
Syahirah, Abdul Halim
Nor Azuana, Ramli
Fault distance calculation considering sequence impedance values on the distribution network
title Fault distance calculation considering sequence impedance values on the distribution network
title_full Fault distance calculation considering sequence impedance values on the distribution network
title_fullStr Fault distance calculation considering sequence impedance values on the distribution network
title_full_unstemmed Fault distance calculation considering sequence impedance values on the distribution network
title_short Fault distance calculation considering sequence impedance values on the distribution network
title_sort fault distance calculation considering sequence impedance values on the distribution network
topic QA Mathematics
TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/41055/
http://umpir.ump.edu.my/id/eprint/41055/
http://umpir.ump.edu.my/id/eprint/41055/1/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network%20-%20Abstract.pdf
http://umpir.ump.edu.my/id/eprint/41055/2/Fault%20Distance%20Calculation%20Considering%20Sequence%20Impedance%20Values%20on%20The%20Distribution%20Network.pdf