Application Of The Non-Destructive Test For FKASA Building Evaluation

The evaluation of concrete quality is important to identify where the concrete needs to do maintained. Non-destructive testing (NDT) has been used more frequently to evaluate the condition of buildings. This evaluation includes a wide range of activities, including a simple visual inspection. During...

Full description

Bibliographic Details
Main Author: Muhammad Afnan Syamim, Abdul Manaf
Format: Undergraduates Project Papers
Language:English
Published: 2023
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/41023/
http://umpir.ump.edu.my/id/eprint/41023/1/RA21126_DRA2844_THESIS_22231.pdf
_version_ 1848826214226067456
author Muhammad Afnan Syamim, Abdul Manaf
author_facet Muhammad Afnan Syamim, Abdul Manaf
author_sort Muhammad Afnan Syamim, Abdul Manaf
building UMP Institutional Repository
collection Online Access
description The evaluation of concrete quality is important to identify where the concrete needs to do maintained. Non-destructive testing (NDT) has been used more frequently to evaluate the condition of buildings. This evaluation includes a wide range of activities, including a simple visual inspection. During the maintenance stage, buildings are monitored more often. Special efforts have been placed on the complementary application of various NDT techniques into an integrated structural health monitoring (SHM) system. The main objective of the study is to evaluate the condition of the reinforced concrete structure at Universiti Malaysia Pahang Kampus Paya Besar, Gambang. The present study used the non-destructive test (NDT) tools to determine the condition of the FKASA building. Two major types of building structures, namely, beams and columns were selected to assess the building’s quality. Two NDT tests used are rebound hammer (RH) and ultrasonic pulse velocity (UPV). Finally, the results and analysis show that the condition of the beams and columns at the FKASA building is satisfactory and poor. For the strength beams and columns, it was found that the condition for both structure elements was a very good hard layer and fair, respectively.
first_indexed 2025-11-15T03:41:15Z
format Undergraduates Project Papers
id ump-41023
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:41:15Z
publishDate 2023
recordtype eprints
repository_type Digital Repository
spelling ump-410232024-04-22T07:13:11Z http://umpir.ump.edu.my/id/eprint/41023/ Application Of The Non-Destructive Test For FKASA Building Evaluation Muhammad Afnan Syamim, Abdul Manaf T Technology (General) TA Engineering (General). Civil engineering (General) The evaluation of concrete quality is important to identify where the concrete needs to do maintained. Non-destructive testing (NDT) has been used more frequently to evaluate the condition of buildings. This evaluation includes a wide range of activities, including a simple visual inspection. During the maintenance stage, buildings are monitored more often. Special efforts have been placed on the complementary application of various NDT techniques into an integrated structural health monitoring (SHM) system. The main objective of the study is to evaluate the condition of the reinforced concrete structure at Universiti Malaysia Pahang Kampus Paya Besar, Gambang. The present study used the non-destructive test (NDT) tools to determine the condition of the FKASA building. Two major types of building structures, namely, beams and columns were selected to assess the building’s quality. Two NDT tests used are rebound hammer (RH) and ultrasonic pulse velocity (UPV). Finally, the results and analysis show that the condition of the beams and columns at the FKASA building is satisfactory and poor. For the strength beams and columns, it was found that the condition for both structure elements was a very good hard layer and fair, respectively. 2023-02 Undergraduates Project Papers NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/41023/1/RA21126_DRA2844_THESIS_22231.pdf Muhammad Afnan Syamim, Abdul Manaf (2023) Application Of The Non-Destructive Test For FKASA Building Evaluation. Faculty of Civil Engineering Technology, Universiti Malaysia Pahang Al-Sultan Abdullah.
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
Muhammad Afnan Syamim, Abdul Manaf
Application Of The Non-Destructive Test For FKASA Building Evaluation
title Application Of The Non-Destructive Test For FKASA Building Evaluation
title_full Application Of The Non-Destructive Test For FKASA Building Evaluation
title_fullStr Application Of The Non-Destructive Test For FKASA Building Evaluation
title_full_unstemmed Application Of The Non-Destructive Test For FKASA Building Evaluation
title_short Application Of The Non-Destructive Test For FKASA Building Evaluation
title_sort application of the non-destructive test for fkasa building evaluation
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
url http://umpir.ump.edu.my/id/eprint/41023/
http://umpir.ump.edu.my/id/eprint/41023/1/RA21126_DRA2844_THESIS_22231.pdf