Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes

An amperometric enzyme-free hydrogen peroxide (H2O2) sensor was developed by catalytically stabilizing active gold nanoparticles (Au NPs) of 4–5 nm on a porous titanium dioxide nanotube (TiO2 NTs) electrode. The Au NPs were homogeneously distributed on anatase TiO2 NTs with an outer diameter of ~102...

Full description

Bibliographic Details
Main Authors: Kader, Md. Ashraful, Nina Suhaity, Azmi, Kafi, A. K. M., Hossain, Md. Sanower, Jose, Rajan, Goh, Khang Wen
Format: Article
Language:English
Published: MDPI 2023
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/39948/
http://umpir.ump.edu.my/id/eprint/39948/1/biosensors-13-00671.pdf
_version_ 1848825911002005504
author Kader, Md. Ashraful
Nina Suhaity, Azmi
Kafi, A. K. M.
Hossain, Md. Sanower
Jose, Rajan
Goh, Khang Wen
author_facet Kader, Md. Ashraful
Nina Suhaity, Azmi
Kafi, A. K. M.
Hossain, Md. Sanower
Jose, Rajan
Goh, Khang Wen
author_sort Kader, Md. Ashraful
building UMP Institutional Repository
collection Online Access
description An amperometric enzyme-free hydrogen peroxide (H2O2) sensor was developed by catalytically stabilizing active gold nanoparticles (Au NPs) of 4–5 nm on a porous titanium dioxide nanotube (TiO2 NTs) electrode. The Au NPs were homogeneously distributed on anatase TiO2 NTs with an outer diameter of ~102 nm, an inner diameter of ~60 nm, and a wall of thickness of ~40 nm. The cyclic voltammogram of the composite electrode showed a pair of redox peaks characterizing the electrocatalytic reduction of H2O2. The entrapping of Au NPs on TiO2 NTs prevented aggregation and facilitated good electrical conductivity and electron transfer rate, thus generating a wide linear range, a low detection limit of ~104 nM, and high sensitivity of ~519 µA/mM, as well as excellent selectivity, reproducibility, repeatability, and stability over 60 days. Furthermore, excellent recovery and relative standard deviation (RSD) were achieved in real samples, which were tap water, milk, and Lactobacillus plantarum bacteria, thereby verifying the accuracy and potentiality of the developed nonenzymatic sensor.
first_indexed 2025-11-15T03:36:26Z
format Article
id ump-39948
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:36:26Z
publishDate 2023
publisher MDPI
recordtype eprints
repository_type Digital Repository
spelling ump-399482024-01-11T01:32:53Z http://umpir.ump.edu.my/id/eprint/39948/ Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes Kader, Md. Ashraful Nina Suhaity, Azmi Kafi, A. K. M. Hossain, Md. Sanower Jose, Rajan Goh, Khang Wen TP Chemical technology An amperometric enzyme-free hydrogen peroxide (H2O2) sensor was developed by catalytically stabilizing active gold nanoparticles (Au NPs) of 4–5 nm on a porous titanium dioxide nanotube (TiO2 NTs) electrode. The Au NPs were homogeneously distributed on anatase TiO2 NTs with an outer diameter of ~102 nm, an inner diameter of ~60 nm, and a wall of thickness of ~40 nm. The cyclic voltammogram of the composite electrode showed a pair of redox peaks characterizing the electrocatalytic reduction of H2O2. The entrapping of Au NPs on TiO2 NTs prevented aggregation and facilitated good electrical conductivity and electron transfer rate, thus generating a wide linear range, a low detection limit of ~104 nM, and high sensitivity of ~519 µA/mM, as well as excellent selectivity, reproducibility, repeatability, and stability over 60 days. Furthermore, excellent recovery and relative standard deviation (RSD) were achieved in real samples, which were tap water, milk, and Lactobacillus plantarum bacteria, thereby verifying the accuracy and potentiality of the developed nonenzymatic sensor. MDPI 2023-07 Article PeerReviewed pdf en cc_by_4 http://umpir.ump.edu.my/id/eprint/39948/1/biosensors-13-00671.pdf Kader, Md. Ashraful and Nina Suhaity, Azmi and Kafi, A. K. M. and Hossain, Md. Sanower and Jose, Rajan and Goh, Khang Wen (2023) Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes. Biosensors, 13 (7). pp. 1-17. ISSN 2079-6374. (Published) https://doi.org/10.3390/bios13070671 https://doi.org/10.3390/bios13070671
spellingShingle TP Chemical technology
Kader, Md. Ashraful
Nina Suhaity, Azmi
Kafi, A. K. M.
Hossain, Md. Sanower
Jose, Rajan
Goh, Khang Wen
Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes
title Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes
title_full Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes
title_fullStr Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes
title_full_unstemmed Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes
title_short Ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes
title_sort ultrasensitive nonenzymatic real-time hydrogen peroxide monitoring using gold nanoparticle-decorated titanium dioxide nanotube electrodes
topic TP Chemical technology
url http://umpir.ump.edu.my/id/eprint/39948/
http://umpir.ump.edu.my/id/eprint/39948/
http://umpir.ump.edu.my/id/eprint/39948/
http://umpir.ump.edu.my/id/eprint/39948/1/biosensors-13-00671.pdf