Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation

One of the devices used to improve heat transfer in heat exchangers is the decaying swirl generator. When the inlet flow passes through this turbulator, a swirling flow is created, which thins the boundary layer on the tube wall and improves the flow's force convection. This paper numerically i...

Full description

Bibliographic Details
Main Authors: At-Tasneem, Mohd Amin, Azmi, W. H., M. A, Ismail
Format: Conference or Workshop Item
Language:English
English
Published: Springer 2023
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/39277/
http://umpir.ump.edu.my/id/eprint/39277/1/Intro-Thermal%E2%80%93Hydraulic%20Performance%20ofWater%20Ethylene%20Glycol%20Mixture%20Through%20Guide-Vane%20Swirl%20Generator%20A%20Numerical%20Simulation.png
http://umpir.ump.edu.my/id/eprint/39277/2/Thermal%E2%80%93Hydraulic%20Performance%20ofWater%20Ethylene%20Glycol%20Mixture%20Through%20Guide-Vane%20Swirl%20Generator%20A%20Numerical%20Simulation.pdf
_version_ 1848825726688559104
author At-Tasneem, Mohd Amin
Azmi, W. H.
M. A, Ismail
author_facet At-Tasneem, Mohd Amin
Azmi, W. H.
M. A, Ismail
author_sort At-Tasneem, Mohd Amin
building UMP Institutional Repository
collection Online Access
description One of the devices used to improve heat transfer in heat exchangers is the decaying swirl generator. When the inlet flow passes through this turbulator, a swirling flow is created, which thins the boundary layer on the tube wall and improves the flow's force convection. This paper numerically investigated a new design of a decaying swirl generator known as the guide-vane swirl generator (GVSG). The GVSG has a diameter of 15.5 mm and a length of 35 mm, and it is placed at L/D = 10 in a tube with a diameter of 16 mm and a length of L/D = 93.75. It has four vanes, each with a length of L/D = 1 and half of each twisted 180°. With a constant heat flux applied to the tube, the heat transfer enhancement was tested for Reynolds numbers ranging from 4583 to 35,000. Ansys Fluent was used throughout the simulation process. The friction factor obtained a maximum value of 4.06 at the highest Reynolds number tested. The Nusselt number achieved a maximum value of 1.23 at Reynolds number 20,000. As a result, the maximum thermal-hydraulic performance (THP) of GVSG inside the heated plain horizontal tube is 0.81 achieved at Reynolds number 35,000. Since THP was less than unity, it is clear that GVSG causes a greater deficit in pressure drop than they promote heat transfer. As a result, the geometry of the GVSG proposed in this paper, such as its length, diameter, vane length, and twist angle, need to be adjusted to improve the GVSG's THP.
first_indexed 2025-11-15T03:33:30Z
format Conference or Workshop Item
id ump-39277
institution Universiti Malaysia Pahang
institution_category Local University
language English
English
last_indexed 2025-11-15T03:33:30Z
publishDate 2023
publisher Springer
recordtype eprints
repository_type Digital Repository
spelling ump-392772023-11-10T07:45:25Z http://umpir.ump.edu.my/id/eprint/39277/ Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation At-Tasneem, Mohd Amin Azmi, W. H. M. A, Ismail TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering One of the devices used to improve heat transfer in heat exchangers is the decaying swirl generator. When the inlet flow passes through this turbulator, a swirling flow is created, which thins the boundary layer on the tube wall and improves the flow's force convection. This paper numerically investigated a new design of a decaying swirl generator known as the guide-vane swirl generator (GVSG). The GVSG has a diameter of 15.5 mm and a length of 35 mm, and it is placed at L/D = 10 in a tube with a diameter of 16 mm and a length of L/D = 93.75. It has four vanes, each with a length of L/D = 1 and half of each twisted 180°. With a constant heat flux applied to the tube, the heat transfer enhancement was tested for Reynolds numbers ranging from 4583 to 35,000. Ansys Fluent was used throughout the simulation process. The friction factor obtained a maximum value of 4.06 at the highest Reynolds number tested. The Nusselt number achieved a maximum value of 1.23 at Reynolds number 20,000. As a result, the maximum thermal-hydraulic performance (THP) of GVSG inside the heated plain horizontal tube is 0.81 achieved at Reynolds number 35,000. Since THP was less than unity, it is clear that GVSG causes a greater deficit in pressure drop than they promote heat transfer. As a result, the geometry of the GVSG proposed in this paper, such as its length, diameter, vane length, and twist angle, need to be adjusted to improve the GVSG's THP. Springer 2023 Conference or Workshop Item PeerReviewed image en http://umpir.ump.edu.my/id/eprint/39277/1/Intro-Thermal%E2%80%93Hydraulic%20Performance%20ofWater%20Ethylene%20Glycol%20Mixture%20Through%20Guide-Vane%20Swirl%20Generator%20A%20Numerical%20Simulation.png pdf en http://umpir.ump.edu.my/id/eprint/39277/2/Thermal%E2%80%93Hydraulic%20Performance%20ofWater%20Ethylene%20Glycol%20Mixture%20Through%20Guide-Vane%20Swirl%20Generator%20A%20Numerical%20Simulation.pdf At-Tasneem, Mohd Amin and Azmi, W. H. and M. A, Ismail (2023) Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation. In: 6th International Conference in Mechanical Engineering Research, ICMER 2021 , 26-27 October , Virtual, Online. pp. 159-170. (281799). ISSN 2195-4356 (Published) https://doi.org/10.1007/978-981-19-1457-7_12
spellingShingle TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
At-Tasneem, Mohd Amin
Azmi, W. H.
M. A, Ismail
Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation
title Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation
title_full Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation
title_fullStr Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation
title_full_unstemmed Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation
title_short Thermal–Hydraulic Performance of Water: Ethylene Glycol Mixture Through Guide-Vane Swirl Generator: A Numerical Simulation
title_sort thermal–hydraulic performance of water: ethylene glycol mixture through guide-vane swirl generator: a numerical simulation
topic TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/39277/
http://umpir.ump.edu.my/id/eprint/39277/
http://umpir.ump.edu.my/id/eprint/39277/1/Intro-Thermal%E2%80%93Hydraulic%20Performance%20ofWater%20Ethylene%20Glycol%20Mixture%20Through%20Guide-Vane%20Swirl%20Generator%20A%20Numerical%20Simulation.png
http://umpir.ump.edu.my/id/eprint/39277/2/Thermal%E2%80%93Hydraulic%20Performance%20ofWater%20Ethylene%20Glycol%20Mixture%20Through%20Guide-Vane%20Swirl%20Generator%20A%20Numerical%20Simulation.pdf