Study on the microbial growth inhibition by using pineapple leaves juice

This thesis presents new techniques for voltage stability assessment and improvement in power system under multi-<::ontingencies. A line-based voltage stability index termed as Static Voltage Stability Index (SVSI) was used to evaluate the voltage stability condition on a line. The value of SVSI...

Full description

Bibliographic Details
Main Author: Amirah, Ya'acob
Format: Thesis
Language:English
Published: 2022
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/38984/
http://umpir.ump.edu.my/id/eprint/38984/1/ir.Study%20on%20the%20microbial%20growth%20inhibition%20by%20using%20pineapple%20leaves%20juice.pdf
_version_ 1848825651091472384
author Amirah, Ya'acob
author_facet Amirah, Ya'acob
author_sort Amirah, Ya'acob
building UMP Institutional Repository
collection Online Access
description This thesis presents new techniques for voltage stability assessment and improvement in power system under multi-<::ontingencies. A line-based voltage stability index termed as Static Voltage Stability Index (SVSI) was used to evaluate the voltage stability condition on a line. The value of SVSI was computed to identify the most sensitive line and corresponding weak bus in the system. The results obtained from the voltage stability analysis using SVSJ were utilized to identify most sensitive line corresponds to a load bus and estimate the maximum loadability and operating margin in the system. The SVSJ was consequently used as the line outage severity indicator in the implementation of contingency analysis and ranking. The application of SVSI was extended for the evaluation of the constrained power planning (CPP) and Flexible AC Transmission Systems (FACTS) devices installation using Evolutionary Programming (EP) by considering multi-contingencies occurrence in the system. The minimizations of SVSJ and transmission loss are used as two separate objective functions for the development of optimization technique. The effect of reactive power load variation on transmission loss in the system is also investigated. Consequently. the EP optimization technique is extended for the evaluation of the operating generator scheduling (OGS) to be applied on reactive power control in power system. The resu Its obtained from the study can be used by the power system operators to make a decision either to achieve minimal SVSI. minimal transmission loss or minimal installation cost. This has also avoided all generators to dispatch power at the same time. Finally, a novel multi-objective Constrained Reactive Power Control (CRPC) algorithm using the state-of-the-art of EP for voltage stability improvement has been developed. A performance comparison with Artificial Immune System (AlS) in terms of SVSJ and loss minimization was made and it is found that the proposed algorithm has been able to produce better results as compared to AlS. The contributions of the studies among the others are the development EP and AIS engine for CPP considered multi-contingencies (N-111). The development of EP and AIS engine for FACTS installation considered multi-contingencies (N-m) for the determination of FACTS placement using SVSJ and optimal sizing of FACTS using EP and AIS, the development of new technique for OGS based on EP optimization technique and the development of multi-objective EP and AJS engines for CRPC considered multi-contingencies (N-m).
first_indexed 2025-11-15T03:32:18Z
format Thesis
id ump-38984
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:32:18Z
publishDate 2022
recordtype eprints
repository_type Digital Repository
spelling ump-389842023-10-23T09:36:38Z http://umpir.ump.edu.my/id/eprint/38984/ Study on the microbial growth inhibition by using pineapple leaves juice Amirah, Ya'acob TA Engineering (General). Civil engineering (General) TK Electrical engineering. Electronics Nuclear engineering This thesis presents new techniques for voltage stability assessment and improvement in power system under multi-<::ontingencies. A line-based voltage stability index termed as Static Voltage Stability Index (SVSI) was used to evaluate the voltage stability condition on a line. The value of SVSI was computed to identify the most sensitive line and corresponding weak bus in the system. The results obtained from the voltage stability analysis using SVSJ were utilized to identify most sensitive line corresponds to a load bus and estimate the maximum loadability and operating margin in the system. The SVSJ was consequently used as the line outage severity indicator in the implementation of contingency analysis and ranking. The application of SVSI was extended for the evaluation of the constrained power planning (CPP) and Flexible AC Transmission Systems (FACTS) devices installation using Evolutionary Programming (EP) by considering multi-contingencies occurrence in the system. The minimizations of SVSJ and transmission loss are used as two separate objective functions for the development of optimization technique. The effect of reactive power load variation on transmission loss in the system is also investigated. Consequently. the EP optimization technique is extended for the evaluation of the operating generator scheduling (OGS) to be applied on reactive power control in power system. The resu Its obtained from the study can be used by the power system operators to make a decision either to achieve minimal SVSI. minimal transmission loss or minimal installation cost. This has also avoided all generators to dispatch power at the same time. Finally, a novel multi-objective Constrained Reactive Power Control (CRPC) algorithm using the state-of-the-art of EP for voltage stability improvement has been developed. A performance comparison with Artificial Immune System (AlS) in terms of SVSJ and loss minimization was made and it is found that the proposed algorithm has been able to produce better results as compared to AlS. The contributions of the studies among the others are the development EP and AIS engine for CPP considered multi-contingencies (N-111). The development of EP and AIS engine for FACTS installation considered multi-contingencies (N-m) for the determination of FACTS placement using SVSJ and optimal sizing of FACTS using EP and AIS, the development of new technique for OGS based on EP optimization technique and the development of multi-objective EP and AJS engines for CRPC considered multi-contingencies (N-m). 2022-03 Thesis NonPeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/38984/1/ir.Study%20on%20the%20microbial%20growth%20inhibition%20by%20using%20pineapple%20leaves%20juice.pdf Amirah, Ya'acob (2022) Study on the microbial growth inhibition by using pineapple leaves juice. Masters thesis, Universiti Malaysia Pahang (Contributors, Thesis advisor: Norazwina, Zainol).
spellingShingle TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
Amirah, Ya'acob
Study on the microbial growth inhibition by using pineapple leaves juice
title Study on the microbial growth inhibition by using pineapple leaves juice
title_full Study on the microbial growth inhibition by using pineapple leaves juice
title_fullStr Study on the microbial growth inhibition by using pineapple leaves juice
title_full_unstemmed Study on the microbial growth inhibition by using pineapple leaves juice
title_short Study on the microbial growth inhibition by using pineapple leaves juice
title_sort study on the microbial growth inhibition by using pineapple leaves juice
topic TA Engineering (General). Civil engineering (General)
TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/38984/
http://umpir.ump.edu.my/id/eprint/38984/1/ir.Study%20on%20the%20microbial%20growth%20inhibition%20by%20using%20pineapple%20leaves%20juice.pdf