Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5)

Breast cancer is a fatal condition that kills thousands of people annually and is becoming more common. Lowering the mortality rate linked to breast cancer requires early detection. On the other hand, screening tests like mammography, ultrasound, and MRI that rely on human interpretation run the ris...

Full description

Bibliographic Details
Main Authors: Nadarajan, Ravindran, Sulaiman, Noorazliza
Format: Conference or Workshop Item
Language:English
English
Published: IEEE 2023
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/37706/
http://umpir.ump.edu.my/id/eprint/37706/1/Evaluation%20of%20K-fold%20value%20in%20breast%20cancer%20diagnosis%20technique%20.pdf
http://umpir.ump.edu.my/id/eprint/37706/2/Evaluation%20of%20K-fold%20value%20in%20breast%20cancer%20diagnosis%20technique.pdf
_version_ 1848825324926664704
author Nadarajan, Ravindran
Sulaiman, Noorazliza
author_facet Nadarajan, Ravindran
Sulaiman, Noorazliza
author_sort Nadarajan, Ravindran
building UMP Institutional Repository
collection Online Access
description Breast cancer is a fatal condition that kills thousands of people annually and is becoming more common. Lowering the mortality rate linked to breast cancer requires early detection. On the other hand, screening tests like mammography, ultrasound, and MRI that rely on human interpretation run the risk of overdiagnosis or underdiagnosis. Classification techniques can be used to improve the accuracy of breast cancer diagnosis to get around this limitation. The purpose of this study is to determine how K-fold cross validation affects breast cancer classification performance. The K-fold value is crucial in determining the right value to use in order to speed up evaluation and guarantee consistency in the analysis. The study looks at how breast cancer identification accuracy is impacted by the K-fold value. The accuracy of the algorithmic performance estimation depends on K. Finding the right K value is crucial because a higher value of K produces an estimate that is more accurate but also costs more to compute. For practical classification performance analysis, a K-fold value of K5 is advised based on the Wisconsin dataset results. With an accuracy rate of 98.49% and an average completion time of 2677.823 seconds, this value showed superior robustness and completion time. This study emphasises the need for and value of K-fold cross-validation in enhancing the classification accuracy of breast cancer.
first_indexed 2025-11-15T03:27:07Z
format Conference or Workshop Item
id ump-37706
institution Universiti Malaysia Pahang
institution_category Local University
language English
English
last_indexed 2025-11-15T03:27:07Z
publishDate 2023
publisher IEEE
recordtype eprints
repository_type Digital Repository
spelling ump-377062023-12-13T04:22:41Z http://umpir.ump.edu.my/id/eprint/37706/ Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5) Nadarajan, Ravindran Sulaiman, Noorazliza TK Electrical engineering. Electronics Nuclear engineering Breast cancer is a fatal condition that kills thousands of people annually and is becoming more common. Lowering the mortality rate linked to breast cancer requires early detection. On the other hand, screening tests like mammography, ultrasound, and MRI that rely on human interpretation run the risk of overdiagnosis or underdiagnosis. Classification techniques can be used to improve the accuracy of breast cancer diagnosis to get around this limitation. The purpose of this study is to determine how K-fold cross validation affects breast cancer classification performance. The K-fold value is crucial in determining the right value to use in order to speed up evaluation and guarantee consistency in the analysis. The study looks at how breast cancer identification accuracy is impacted by the K-fold value. The accuracy of the algorithmic performance estimation depends on K. Finding the right K value is crucial because a higher value of K produces an estimate that is more accurate but also costs more to compute. For practical classification performance analysis, a K-fold value of K5 is advised based on the Wisconsin dataset results. With an accuracy rate of 98.49% and an average completion time of 2677.823 seconds, this value showed superior robustness and completion time. This study emphasises the need for and value of K-fold cross-validation in enhancing the classification accuracy of breast cancer. IEEE 2023 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/37706/1/Evaluation%20of%20K-fold%20value%20in%20breast%20cancer%20diagnosis%20technique%20.pdf pdf en http://umpir.ump.edu.my/id/eprint/37706/2/Evaluation%20of%20K-fold%20value%20in%20breast%20cancer%20diagnosis%20technique.pdf Nadarajan, Ravindran and Sulaiman, Noorazliza (2023) Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5). In: IEEE 13th Symposium on Computer Applications & Industrial Electronics (ISCAIE 2023) , 20 - 21 May 2023 , Penang, Malaysia. pp. 130-135.. ISBN 979-8-3503-4731-9 (Published) https://doi.org/10.1109/ISCAIE57739.2023.10165432
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Nadarajan, Ravindran
Sulaiman, Noorazliza
Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5)
title Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5)
title_full Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5)
title_fullStr Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5)
title_full_unstemmed Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5)
title_short Evaluation of K-fold value in breast cancer diagnosis technique using SVM and bio-inspired optimization algorithm (JA-ABC5)
title_sort evaluation of k-fold value in breast cancer diagnosis technique using svm and bio-inspired optimization algorithm (ja-abc5)
topic TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/37706/
http://umpir.ump.edu.my/id/eprint/37706/
http://umpir.ump.edu.my/id/eprint/37706/1/Evaluation%20of%20K-fold%20value%20in%20breast%20cancer%20diagnosis%20technique%20.pdf
http://umpir.ump.edu.my/id/eprint/37706/2/Evaluation%20of%20K-fold%20value%20in%20breast%20cancer%20diagnosis%20technique.pdf