Analysis on auger pump performance during handling high viscous liquid

Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferrin...

Full description

Bibliographic Details
Main Authors: Alisha, E., Najwa, N., Jamaludin, A. S., Razali, M. N. M., Saffe, S. N. M.
Format: Article
Language:English
Published: Penerbit UMP 2022
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/35685/
http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf
_version_ 1848824843325145088
author Alisha, E.
Najwa, N.
Jamaludin, A. S.
Razali, M. N. M.
Saffe, S. N. M.
author_facet Alisha, E.
Najwa, N.
Jamaludin, A. S.
Razali, M. N. M.
Saffe, S. N. M.
author_sort Alisha, E.
building UMP Institutional Repository
collection Online Access
description Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferring various viscosity liquids. In the study, a pumping device with auger shaft is designed. The sample liquids chosen for the experiment oil and concentrated detergent that poses various viscosity. The viscosity is being identified roughly by Zahn Cup Method with the temperature kept constant at 26°C throughout the measurement. The performance of the auger pump can be accessed by altering the motor speed in order to get various reading for the flow rate and pressure. It is found in the study; flowrate is affected by viscosity with the increasing motor speed. The study proves that the auger pump can operate with viscosity of 770 cSt liquid.
first_indexed 2025-11-15T03:19:28Z
format Article
id ump-35685
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:19:28Z
publishDate 2022
publisher Penerbit UMP
recordtype eprints
repository_type Digital Repository
spelling ump-356852022-11-10T08:13:26Z http://umpir.ump.edu.my/id/eprint/35685/ Analysis on auger pump performance during handling high viscous liquid Alisha, E. Najwa, N. Jamaludin, A. S. Razali, M. N. M. Saffe, S. N. M. TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TS Manufactures Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferring various viscosity liquids. In the study, a pumping device with auger shaft is designed. The sample liquids chosen for the experiment oil and concentrated detergent that poses various viscosity. The viscosity is being identified roughly by Zahn Cup Method with the temperature kept constant at 26°C throughout the measurement. The performance of the auger pump can be accessed by altering the motor speed in order to get various reading for the flow rate and pressure. It is found in the study; flowrate is affected by viscosity with the increasing motor speed. The study proves that the auger pump can operate with viscosity of 770 cSt liquid. Penerbit UMP 2022-09 Article PeerReviewed pdf en cc_by_4 http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf Alisha, E. and Najwa, N. and Jamaludin, A. S. and Razali, M. N. M. and Saffe, S. N. M. (2022) Analysis on auger pump performance during handling high viscous liquid. Journal of Modern Manufacturing Systems and Technology (JMMST), 6 (2). pp. 48-54. ISSN 2636-9575. (Published) https://doi.org/10.15282/jmmst.v6i2.8564 https://doi.org/10.15282/jmmst.v6i2.8564
spellingShingle TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
TS Manufactures
Alisha, E.
Najwa, N.
Jamaludin, A. S.
Razali, M. N. M.
Saffe, S. N. M.
Analysis on auger pump performance during handling high viscous liquid
title Analysis on auger pump performance during handling high viscous liquid
title_full Analysis on auger pump performance during handling high viscous liquid
title_fullStr Analysis on auger pump performance during handling high viscous liquid
title_full_unstemmed Analysis on auger pump performance during handling high viscous liquid
title_short Analysis on auger pump performance during handling high viscous liquid
title_sort analysis on auger pump performance during handling high viscous liquid
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
TS Manufactures
url http://umpir.ump.edu.my/id/eprint/35685/
http://umpir.ump.edu.my/id/eprint/35685/
http://umpir.ump.edu.my/id/eprint/35685/
http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf