Analysis on auger pump performance during handling high viscous liquid
Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferrin...
| Main Authors: | , , , , |
|---|---|
| Format: | Article |
| Language: | English |
| Published: |
Penerbit UMP
2022
|
| Subjects: | |
| Online Access: | http://umpir.ump.edu.my/id/eprint/35685/ http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf |
| _version_ | 1848824843325145088 |
|---|---|
| author | Alisha, E. Najwa, N. Jamaludin, A. S. Razali, M. N. M. Saffe, S. N. M. |
| author_facet | Alisha, E. Najwa, N. Jamaludin, A. S. Razali, M. N. M. Saffe, S. N. M. |
| author_sort | Alisha, E. |
| building | UMP Institutional Repository |
| collection | Online Access |
| description | Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferring various viscosity liquids. In the study, a pumping device with auger shaft is designed. The sample liquids chosen for the experiment oil and concentrated detergent that poses various viscosity. The viscosity is being identified roughly by Zahn Cup Method with the temperature kept constant at 26°C throughout the measurement. The performance of the auger pump can be accessed by altering the motor speed in order to get various reading for the flow rate and pressure. It is found in the study; flowrate is affected by viscosity with the increasing motor speed. The study proves that the auger pump can operate with viscosity of 770 cSt liquid. |
| first_indexed | 2025-11-15T03:19:28Z |
| format | Article |
| id | ump-35685 |
| institution | Universiti Malaysia Pahang |
| institution_category | Local University |
| language | English |
| last_indexed | 2025-11-15T03:19:28Z |
| publishDate | 2022 |
| publisher | Penerbit UMP |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | ump-356852022-11-10T08:13:26Z http://umpir.ump.edu.my/id/eprint/35685/ Analysis on auger pump performance during handling high viscous liquid Alisha, E. Najwa, N. Jamaludin, A. S. Razali, M. N. M. Saffe, S. N. M. TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TS Manufactures Viscosity is one of the factors affecting the performance of the auger pump. An auger pump is positive-displacement (PD) pump that moves fluids and semi-solid material along the screw axis using one or more screws. The study is about the analysis of the performance of the auger pump when transferring various viscosity liquids. In the study, a pumping device with auger shaft is designed. The sample liquids chosen for the experiment oil and concentrated detergent that poses various viscosity. The viscosity is being identified roughly by Zahn Cup Method with the temperature kept constant at 26°C throughout the measurement. The performance of the auger pump can be accessed by altering the motor speed in order to get various reading for the flow rate and pressure. It is found in the study; flowrate is affected by viscosity with the increasing motor speed. The study proves that the auger pump can operate with viscosity of 770 cSt liquid. Penerbit UMP 2022-09 Article PeerReviewed pdf en cc_by_4 http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf Alisha, E. and Najwa, N. and Jamaludin, A. S. and Razali, M. N. M. and Saffe, S. N. M. (2022) Analysis on auger pump performance during handling high viscous liquid. Journal of Modern Manufacturing Systems and Technology (JMMST), 6 (2). pp. 48-54. ISSN 2636-9575. (Published) https://doi.org/10.15282/jmmst.v6i2.8564 https://doi.org/10.15282/jmmst.v6i2.8564 |
| spellingShingle | TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TS Manufactures Alisha, E. Najwa, N. Jamaludin, A. S. Razali, M. N. M. Saffe, S. N. M. Analysis on auger pump performance during handling high viscous liquid |
| title | Analysis on auger pump performance during handling high viscous liquid |
| title_full | Analysis on auger pump performance during handling high viscous liquid |
| title_fullStr | Analysis on auger pump performance during handling high viscous liquid |
| title_full_unstemmed | Analysis on auger pump performance during handling high viscous liquid |
| title_short | Analysis on auger pump performance during handling high viscous liquid |
| title_sort | analysis on auger pump performance during handling high viscous liquid |
| topic | TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering TS Manufactures |
| url | http://umpir.ump.edu.my/id/eprint/35685/ http://umpir.ump.edu.my/id/eprint/35685/ http://umpir.ump.edu.my/id/eprint/35685/ http://umpir.ump.edu.my/id/eprint/35685/1/Analysis%20on%20Auger%20Pump%20Performance%20During%20Handling.pdf |