Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU
In this study, experimental tests have been carried out on the coupling thermoelectric cooling module with minichannel heatsink subjected to impinging airflow for cooling desktop central processing unit (CPU). A controlled thermoelectric-forced test system was designed for this purpose. This was des...
| Main Authors: | , , , |
|---|---|
| Format: | Article |
| Language: | English English |
| Published: |
Begell House
2021
|
| Subjects: | |
| Online Access: | http://umpir.ump.edu.my/id/eprint/33652/ http://umpir.ump.edu.my/id/eprint/33652/1/Experimental%20investigation%20on%20controlled%20cooling%20by%20coupling.pdf http://umpir.ump.edu.my/id/eprint/33652/7/Experimental%20investigation%20on%20controlled%20cooling%20by%20coupling%20of%20thermoelectric%20and%20an%20air%20impinging%20jet%20for%20CPU.pdf |
| _version_ | 1848824310025682944 |
|---|---|
| author | Abdelillah, Abed Belarbi M'hamed, Beriache Nor Azwadi, Che Sidik Rizalman, Mamat |
| author_facet | Abdelillah, Abed Belarbi M'hamed, Beriache Nor Azwadi, Che Sidik Rizalman, Mamat |
| author_sort | Abdelillah, Abed Belarbi |
| building | UMP Institutional Repository |
| collection | Online Access |
| description | In this study, experimental tests have been carried out on the coupling thermoelectric cooling module with minichannel heatsink subjected to impinging airflow for cooling desktop central processing unit (CPU). A controlled thermoelectric-forced test system was designed for this purpose. This was designed using electronic Arduino card. The proposed hybrid cooling system was compared with the conventional forced air-cooling technique. Three power of heat source (CPU) were adopted, investigated, and compared, namely 60, 87, and 95 W. Performance of controlled thermoelectric cooling with three preset temperature were experimentally examined. The effects of air velocity and thermoelectric input current on the case temperature (Tcase), thermal resistance, and heat transfer coefficient were analyzed. Results showed that the Tcase increases with the increase of its input power. In addition, increasing air jet velocity and thermoelectric input current improve CPU cooling significantly. For a CPU power of 95 W, the recorded Tcase temperature was 57°C with the conventional system. While it was maintained below 50°C in the hybrid system. The thermoelectric cooler has had a major effect on CPU cooling, having 15% improvement over conventional forced air-cooling. However, this was accompanied by an increase in energy consumption in the range of 45 W. |
| first_indexed | 2025-11-15T03:10:59Z |
| format | Article |
| id | ump-33652 |
| institution | Universiti Malaysia Pahang |
| institution_category | Local University |
| language | English English |
| last_indexed | 2025-11-15T03:10:59Z |
| publishDate | 2021 |
| publisher | Begell House |
| recordtype | eprints |
| repository_type | Digital Repository |
| spelling | ump-336522024-01-17T04:22:00Z http://umpir.ump.edu.my/id/eprint/33652/ Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU Abdelillah, Abed Belarbi M'hamed, Beriache Nor Azwadi, Che Sidik Rizalman, Mamat TJ Mechanical engineering and machinery In this study, experimental tests have been carried out on the coupling thermoelectric cooling module with minichannel heatsink subjected to impinging airflow for cooling desktop central processing unit (CPU). A controlled thermoelectric-forced test system was designed for this purpose. This was designed using electronic Arduino card. The proposed hybrid cooling system was compared with the conventional forced air-cooling technique. Three power of heat source (CPU) were adopted, investigated, and compared, namely 60, 87, and 95 W. Performance of controlled thermoelectric cooling with three preset temperature were experimentally examined. The effects of air velocity and thermoelectric input current on the case temperature (Tcase), thermal resistance, and heat transfer coefficient were analyzed. Results showed that the Tcase increases with the increase of its input power. In addition, increasing air jet velocity and thermoelectric input current improve CPU cooling significantly. For a CPU power of 95 W, the recorded Tcase temperature was 57°C with the conventional system. While it was maintained below 50°C in the hybrid system. The thermoelectric cooler has had a major effect on CPU cooling, having 15% improvement over conventional forced air-cooling. However, this was accompanied by an increase in energy consumption in the range of 45 W. Begell House 2021 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/33652/1/Experimental%20investigation%20on%20controlled%20cooling%20by%20coupling.pdf pdf en http://umpir.ump.edu.my/id/eprint/33652/7/Experimental%20investigation%20on%20controlled%20cooling%20by%20coupling%20of%20thermoelectric%20and%20an%20air%20impinging%20jet%20for%20CPU.pdf Abdelillah, Abed Belarbi and M'hamed, Beriache and Nor Azwadi, Che Sidik and Rizalman, Mamat (2021) Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU. Heat Transfer Research, 50 (3). pp. 1-2. ISSN 1064-2285(Print); 2162-6561(Online). (Published) https://doi.org/10.1002/htj.21976 https://doi.org/10.1002/htj.21976 |
| spellingShingle | TJ Mechanical engineering and machinery Abdelillah, Abed Belarbi M'hamed, Beriache Nor Azwadi, Che Sidik Rizalman, Mamat Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU |
| title | Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU |
| title_full | Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU |
| title_fullStr | Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU |
| title_full_unstemmed | Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU |
| title_short | Experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for CPU |
| title_sort | experimental investigation on controlled cooling by coupling of thermoelectric and an air impinging jet for cpu |
| topic | TJ Mechanical engineering and machinery |
| url | http://umpir.ump.edu.my/id/eprint/33652/ http://umpir.ump.edu.my/id/eprint/33652/ http://umpir.ump.edu.my/id/eprint/33652/ http://umpir.ump.edu.my/id/eprint/33652/1/Experimental%20investigation%20on%20controlled%20cooling%20by%20coupling.pdf http://umpir.ump.edu.my/id/eprint/33652/7/Experimental%20investigation%20on%20controlled%20cooling%20by%20coupling%20of%20thermoelectric%20and%20an%20air%20impinging%20jet%20for%20CPU.pdf |