Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system

Proportional–integral–derivative (PID) controller is one of the linear control methods of closed-loop irrigation control. Today, it is mostly used in the industry to regulate industrial process variables such as pressure, flow rate, temperature, heat, and others. In precision farming, the use of tec...

Full description

Bibliographic Details
Main Authors: Yong, Wai Xhuen, Ahmad Najmuddin, Ibrahim
Format: Article
Language:English
Published: Penerbit UMP 2020
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/33629/
http://umpir.ump.edu.my/id/eprint/33629/1/Field%20study%20of%20PID%20parameter%20tuning%20investigation.pdf
_version_ 1848824303519268864
author Yong, Wai Xhuen
Ahmad Najmuddin, Ibrahim
author_facet Yong, Wai Xhuen
Ahmad Najmuddin, Ibrahim
author_sort Yong, Wai Xhuen
building UMP Institutional Repository
collection Online Access
description Proportional–integral–derivative (PID) controller is one of the linear control methods of closed-loop irrigation control. Today, it is mostly used in the industry to regulate industrial process variables such as pressure, flow rate, temperature, heat, and others. In precision farming, the use of technologies such as sensors and PID controllers is popular nowadays. The technologies help the farmer fasten the fertilizer's mixing process before using it directly to the crop. However, not all farms afford to use high technology, and using low-cost mixing systems is one way to reduce their cost. Therefore, this research investigates the accuracy of fertilizer mixture using low-cost methods, compares the results, and proposes improvements to ensure a better fertilizer distribution for precision farming. Different parameter tuning will affect the mixing process of the fertilizer. A series of experiments will be conducted based on the PID control parameter, the concentration of the salt solution, and the initial amount of nutrients in the mixing tank. The salt solution will be used as an alternative for the fertilizer because it contains some similar composition ingredients that the EC sensor can detect. The experiment starts with a preliminary test to determine the temperature effect on reading where room temperature will be the best for the next experiment. The best PID parameter that is used is K_P= 130 and K_I= 60 to prevent the phenomenon of overshoot occur during the mixing process. Using the same PID parameter for the next experiment had also found out that the higher the concentration of the salt solution, the higher the chance occur the phenomenon of overshoot. The initial amount of nutrients inside the mixing tank does not affect much for the mixing process because the best parameter for the experiment we had found from the previous experiment is used. The results extracted from the experiment that shows the mixing process from a low-cost automated fertilizer mixing system.
first_indexed 2025-11-15T03:10:53Z
format Article
id ump-33629
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:10:53Z
publishDate 2020
publisher Penerbit UMP
recordtype eprints
repository_type Digital Repository
spelling ump-336292022-04-05T07:05:52Z http://umpir.ump.edu.my/id/eprint/33629/ Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system Yong, Wai Xhuen Ahmad Najmuddin, Ibrahim T Technology (General) TJ Mechanical engineering and machinery Proportional–integral–derivative (PID) controller is one of the linear control methods of closed-loop irrigation control. Today, it is mostly used in the industry to regulate industrial process variables such as pressure, flow rate, temperature, heat, and others. In precision farming, the use of technologies such as sensors and PID controllers is popular nowadays. The technologies help the farmer fasten the fertilizer's mixing process before using it directly to the crop. However, not all farms afford to use high technology, and using low-cost mixing systems is one way to reduce their cost. Therefore, this research investigates the accuracy of fertilizer mixture using low-cost methods, compares the results, and proposes improvements to ensure a better fertilizer distribution for precision farming. Different parameter tuning will affect the mixing process of the fertilizer. A series of experiments will be conducted based on the PID control parameter, the concentration of the salt solution, and the initial amount of nutrients in the mixing tank. The salt solution will be used as an alternative for the fertilizer because it contains some similar composition ingredients that the EC sensor can detect. The experiment starts with a preliminary test to determine the temperature effect on reading where room temperature will be the best for the next experiment. The best PID parameter that is used is K_P= 130 and K_I= 60 to prevent the phenomenon of overshoot occur during the mixing process. Using the same PID parameter for the next experiment had also found out that the higher the concentration of the salt solution, the higher the chance occur the phenomenon of overshoot. The initial amount of nutrients inside the mixing tank does not affect much for the mixing process because the best parameter for the experiment we had found from the previous experiment is used. The results extracted from the experiment that shows the mixing process from a low-cost automated fertilizer mixing system. Penerbit UMP 2020 Article PeerReviewed pdf en cc_by_nc_4 http://umpir.ump.edu.my/id/eprint/33629/1/Field%20study%20of%20PID%20parameter%20tuning%20investigation.pdf Yong, Wai Xhuen and Ahmad Najmuddin, Ibrahim (2020) Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system. Mekatronika - Journal of Intelligent Manufacturing & Mechatronics, 2 (2). pp. 13-22. ISSN 2637-0883. (Published) https://doi.org/10.15282/mekatronika.v2i2.6742 https://doi.org/10.15282/mekatronika.v2i2.6742
spellingShingle T Technology (General)
TJ Mechanical engineering and machinery
Yong, Wai Xhuen
Ahmad Najmuddin, Ibrahim
Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system
title Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system
title_full Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system
title_fullStr Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system
title_full_unstemmed Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system
title_short Field study of PID parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system
title_sort field study of pid parameter tuning investigation in peristaltic dosing pump control for use in automated fertilizer mixing system
topic T Technology (General)
TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/33629/
http://umpir.ump.edu.my/id/eprint/33629/
http://umpir.ump.edu.my/id/eprint/33629/
http://umpir.ump.edu.my/id/eprint/33629/1/Field%20study%20of%20PID%20parameter%20tuning%20investigation.pdf