Various risks and safety analysis to reduce fire in oil refinery plant

It is quite hazardous to produce the final product of oil or gas in a petrochemical refinery plant due to its flammable or combustible and explosive materials. Small mistakes can cause massive damage to life, property, pollution, injury, ecosystem, and business by fire. The entire system is challeng...

Full description

Bibliographic Details
Main Authors: Alam, Md Zahangir, Shakib, Mohammed Nazmus, Islam, Minarul, Mohammad Jalal, Uddin
Format: Conference or Workshop Item
Language:English
Published: IOP Publishing 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/32528/
http://umpir.ump.edu.my/id/eprint/32528/1/Various%20risks%20and%20safety%20analysis%20to%20reduce%20fire%20in%20oil%20refinery%20plant.pdf
_version_ 1848824043977834496
author Alam, Md Zahangir
Shakib, Mohammed Nazmus
Islam, Minarul
Mohammad Jalal, Uddin
author_facet Alam, Md Zahangir
Shakib, Mohammed Nazmus
Islam, Minarul
Mohammad Jalal, Uddin
author_sort Alam, Md Zahangir
building UMP Institutional Repository
collection Online Access
description It is quite hazardous to produce the final product of oil or gas in a petrochemical refinery plant due to its flammable or combustible and explosive materials. Small mistakes can cause massive damage to life, property, pollution, injury, ecosystem, and business by fire. The entire system is challenging to manage. Therefore, fire risk assessment and forecasting are necessary to overcome personal, environmental, and refinery plants' hazard situations. There have been four main threats in any refinery facility: electrical, mechanical, civil, and chemical issues, maximum cases its result burning. This research aimed to study and assess fire risk in the refinery plant by using a multi-stage early warning system and reducing the fire. The fire hazard safety layer technique would be used for our petrochemical process. Some equipment is set in place to forecast the danger and execution before and after it happens. Geographic information systems (GIS), remote sensing (RS) are some techniques for fire incidents tracking. Flame detectors, heat detectors, and gas detectors are used to maintain good contact in the entire risk analyzer portion. Various techniques and monitoring have been proposed to operate the plant efficiently and safely, like controlling, predicting, and pre-warning strategic planning.
first_indexed 2025-11-15T03:06:46Z
format Conference or Workshop Item
id ump-32528
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:06:46Z
publishDate 2021
publisher IOP Publishing
recordtype eprints
repository_type Digital Repository
spelling ump-325282021-11-09T08:05:29Z http://umpir.ump.edu.my/id/eprint/32528/ Various risks and safety analysis to reduce fire in oil refinery plant Alam, Md Zahangir Shakib, Mohammed Nazmus Islam, Minarul Mohammad Jalal, Uddin TJ Mechanical engineering and machinery TK Electrical engineering. Electronics Nuclear engineering It is quite hazardous to produce the final product of oil or gas in a petrochemical refinery plant due to its flammable or combustible and explosive materials. Small mistakes can cause massive damage to life, property, pollution, injury, ecosystem, and business by fire. The entire system is challenging to manage. Therefore, fire risk assessment and forecasting are necessary to overcome personal, environmental, and refinery plants' hazard situations. There have been four main threats in any refinery facility: electrical, mechanical, civil, and chemical issues, maximum cases its result burning. This research aimed to study and assess fire risk in the refinery plant by using a multi-stage early warning system and reducing the fire. The fire hazard safety layer technique would be used for our petrochemical process. Some equipment is set in place to forecast the danger and execution before and after it happens. Geographic information systems (GIS), remote sensing (RS) are some techniques for fire incidents tracking. Flame detectors, heat detectors, and gas detectors are used to maintain good contact in the entire risk analyzer portion. Various techniques and monitoring have been proposed to operate the plant efficiently and safely, like controlling, predicting, and pre-warning strategic planning. IOP Publishing 2021 Conference or Workshop Item PeerReviewed pdf en cc_by http://umpir.ump.edu.my/id/eprint/32528/1/Various%20risks%20and%20safety%20analysis%20to%20reduce%20fire%20in%20oil%20refinery%20plant.pdf Alam, Md Zahangir and Shakib, Mohammed Nazmus and Islam, Minarul and Mohammad Jalal, Uddin (2021) Various risks and safety analysis to reduce fire in oil refinery plant. In: IOP Conference Series: Materials Science and Engineering, The International Postgraduate Conference on Mechanical Engineering (IPCME 2021) , 19-20 January 2021 , Pekan, Pahang, Malaysia. pp. 1-11., 1078 (012028). ISSN 1757-899X (Published) https://doi.org/10.1088/1757-899X/1078/1/012028
spellingShingle TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
Alam, Md Zahangir
Shakib, Mohammed Nazmus
Islam, Minarul
Mohammad Jalal, Uddin
Various risks and safety analysis to reduce fire in oil refinery plant
title Various risks and safety analysis to reduce fire in oil refinery plant
title_full Various risks and safety analysis to reduce fire in oil refinery plant
title_fullStr Various risks and safety analysis to reduce fire in oil refinery plant
title_full_unstemmed Various risks and safety analysis to reduce fire in oil refinery plant
title_short Various risks and safety analysis to reduce fire in oil refinery plant
title_sort various risks and safety analysis to reduce fire in oil refinery plant
topic TJ Mechanical engineering and machinery
TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/32528/
http://umpir.ump.edu.my/id/eprint/32528/
http://umpir.ump.edu.my/id/eprint/32528/1/Various%20risks%20and%20safety%20analysis%20to%20reduce%20fire%20in%20oil%20refinery%20plant.pdf