Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection

A simple, rapid and sensitive method termed as dispersive liquid–liquid microextraction (DLLME) combined with gas chromatography-electron capture detector (GC-ECD) was developed for the determination of selected organophosphorus pesticides (OPPs) namely chlorpyrifos, dimethoate and diazinon in water...

Full description

Bibliographic Details
Main Authors: Mohd Marsin, Sanagi, Siti Umairah, Mokhtar, Maizatul Akmam, Miskam, Wan Aini, Wan Ibrahim
Format: Article
Language:English
Published: Malaysian Analytical Sciences Society
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/31601/
http://umpir.ump.edu.my/id/eprint/31601/1/MJAS.pdf
_version_ 1848823807672844288
author Mohd Marsin, Sanagi
Siti Umairah, Mokhtar
Maizatul Akmam, Miskam
Wan Aini, Wan Ibrahim
author_facet Mohd Marsin, Sanagi
Siti Umairah, Mokhtar
Maizatul Akmam, Miskam
Wan Aini, Wan Ibrahim
author_sort Mohd Marsin, Sanagi
building UMP Institutional Repository
collection Online Access
description A simple, rapid and sensitive method termed as dispersive liquid–liquid microextraction (DLLME) combined with gas chromatography-electron capture detector (GC-ECD) was developed for the determination of selected organophosphorus pesticides (OPPs) namely chlorpyrifos, dimethoate and diazinon in water sample. In this method, a mixture of carbon disulfide, CS2 (extraction solvent) and methanol (disperser solvent) was rapidly injected using syringe into the 5.00 mL water sample to form a cloudy solution where the OPPs were extracted into the fine droplets of extraction solvent. Upon centrifugation for 3 min at 3500 rpm, the fine droplets were sedimented at the bottom of the centrifuge tube. Sedimented phase (1μL) was injected into the GC-ECD for separation and determination of OPPs. Important extraction parameters, such as type of disperser solvent, volume of extraction solvent and volume of disperser solvent were investigated. The optimized conditions for DLLME of the selected OPPs were methanol as disperser solvent, 30 μL of extraction solvent (CS2) and 1.0 mL of disperser solvent (methanol). Under the optimum extraction conditions, the method showed good linearity in the range of 0.1 to 1.0 μg/mL with correlation coefficient (r2), in the range of 0.9976 to 0.9994 and low limits of detection (LOD) between 0.047 and 0.201 μg/mL. The proposed method provided acceptable recoveries (72.67- 144%) with good RSDs ranging from 2.74% to 7.48%. This method was successfully applied to the determination of OPPs in water samples obtained from a golf course and chlorpyrifos and diazinon were detected at concentration 0.18 μg/mL and 0.07 μg/mL, respectively.
first_indexed 2025-11-15T03:03:00Z
format Article
id ump-31601
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T03:03:00Z
publisher Malaysian Analytical Sciences Society
recordtype eprints
repository_type Digital Repository
spelling ump-316012021-07-15T01:35:55Z http://umpir.ump.edu.my/id/eprint/31601/ Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection Mohd Marsin, Sanagi Siti Umairah, Mokhtar Maizatul Akmam, Miskam Wan Aini, Wan Ibrahim QD Chemistry A simple, rapid and sensitive method termed as dispersive liquid–liquid microextraction (DLLME) combined with gas chromatography-electron capture detector (GC-ECD) was developed for the determination of selected organophosphorus pesticides (OPPs) namely chlorpyrifos, dimethoate and diazinon in water sample. In this method, a mixture of carbon disulfide, CS2 (extraction solvent) and methanol (disperser solvent) was rapidly injected using syringe into the 5.00 mL water sample to form a cloudy solution where the OPPs were extracted into the fine droplets of extraction solvent. Upon centrifugation for 3 min at 3500 rpm, the fine droplets were sedimented at the bottom of the centrifuge tube. Sedimented phase (1μL) was injected into the GC-ECD for separation and determination of OPPs. Important extraction parameters, such as type of disperser solvent, volume of extraction solvent and volume of disperser solvent were investigated. The optimized conditions for DLLME of the selected OPPs were methanol as disperser solvent, 30 μL of extraction solvent (CS2) and 1.0 mL of disperser solvent (methanol). Under the optimum extraction conditions, the method showed good linearity in the range of 0.1 to 1.0 μg/mL with correlation coefficient (r2), in the range of 0.9976 to 0.9994 and low limits of detection (LOD) between 0.047 and 0.201 μg/mL. The proposed method provided acceptable recoveries (72.67- 144%) with good RSDs ranging from 2.74% to 7.48%. This method was successfully applied to the determination of OPPs in water samples obtained from a golf course and chlorpyrifos and diazinon were detected at concentration 0.18 μg/mL and 0.07 μg/mL, respectively. Malaysian Analytical Sciences Society Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/31601/1/MJAS.pdf Mohd Marsin, Sanagi and Siti Umairah, Mokhtar and Maizatul Akmam, Miskam and Wan Aini, Wan Ibrahim Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection. The Malaysian Journal of Analytical Sciences, 15 (2). pp. 232-239. ISSN 1394-2506. (Published)
spellingShingle QD Chemistry
Mohd Marsin, Sanagi
Siti Umairah, Mokhtar
Maizatul Akmam, Miskam
Wan Aini, Wan Ibrahim
Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection
title Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection
title_full Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection
title_fullStr Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection
title_full_unstemmed Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection
title_short Determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection
title_sort determination of organophosphorus pesticides by dispersive liquid-liquid microextraction coupled with gas chromatography-electron capture detection
topic QD Chemistry
url http://umpir.ump.edu.my/id/eprint/31601/
http://umpir.ump.edu.my/id/eprint/31601/1/MJAS.pdf