Remediation of aquaculture effluents using physical treatment

The wastewater of the aquaculture industry contains harmful pollutants that have harmful effects on aquatic life and population. The main concern is the high values of biological oxygen demand (BOD), chemical oxygen demand (COD), and ammoniacal nitrogen in wastewater, which do not comply with the En...

Full description

Bibliographic Details
Main Authors: M. Taqiuddin, Karia, A. Hazim, Haziq, Najmuddin, Mohd Ramli, Mohd Khairul Nizam, Mohd Zuhan, Mohd Najib, Razali
Format: Conference or Workshop Item
Language:English
English
Published: 2021
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/30978/
http://umpir.ump.edu.my/id/eprint/30978/1/18.%20Remediation%20of%20aquaculture%20effluents%20using%20physical%20treatment.pdf
http://umpir.ump.edu.my/id/eprint/30978/2/18.1%20Remediation%20of%20aquaculture%20effluents%20using%20physical%20treatment.pdf
_version_ 1848823651781050368
author M. Taqiuddin, Karia
A. Hazim, Haziq
Najmuddin, Mohd Ramli
Mohd Khairul Nizam, Mohd Zuhan
Mohd Najib, Razali
author_facet M. Taqiuddin, Karia
A. Hazim, Haziq
Najmuddin, Mohd Ramli
Mohd Khairul Nizam, Mohd Zuhan
Mohd Najib, Razali
author_sort M. Taqiuddin, Karia
building UMP Institutional Repository
collection Online Access
description The wastewater of the aquaculture industry contains harmful pollutants that have harmful effects on aquatic life and population. The main concern is the high values of biological oxygen demand (BOD), chemical oxygen demand (COD), and ammoniacal nitrogen in wastewater, which do not comply with the Environmental Quality (Industrial Effluents) Regulations 2009 under the Environmental Quality Act (1974), the Department of Environment (DOE), Malaysia. This study aims to evaluate the efficiency of natural and commercial wastewater treatment of aquaculture wastewater. Two natural reagents (activated carbon (AC) and MNRg-Treat powder) and a biological coagulant (MNRg-Treat liquid) were used to treat aquaculture wastewater samples. Nine beakers were used in this treatment, and 1.5 L of wastewater samples from the shrimp, tilapia, and patin ponds were poured into three beakers. After that, 7.5% by weight of each reagent was added to 1.5 L of wastewater for each sample and left for three days without mechanical assistance. Then, five parameters were analyzed for the samples in each beaker: pH, BOD, COD, dissolved oxygen (DO), and ammoniacal nitrogen. The results showed that AC is the best material to reduce ammoniacal nitrogen. The ammoniacal nitrogen level of the tilapia pond reduced by 58.82% and the patin pond reduced by 30.77% using AC, followed by 17.64% reduction using MNRg-Treat liquid for the tilapia pond. Meanwhile, MNRg-Treat powder recorded 5.88% reduction for the tilapia pond. The obtained results showed that the treatment agents demonstrated their best performance at 7.5 wt. %.
first_indexed 2025-11-15T03:00:32Z
format Conference or Workshop Item
id ump-30978
institution Universiti Malaysia Pahang
institution_category Local University
language English
English
last_indexed 2025-11-15T03:00:32Z
publishDate 2021
recordtype eprints
repository_type Digital Repository
spelling ump-309782021-04-23T04:08:09Z http://umpir.ump.edu.my/id/eprint/30978/ Remediation of aquaculture effluents using physical treatment M. Taqiuddin, Karia A. Hazim, Haziq Najmuddin, Mohd Ramli Mohd Khairul Nizam, Mohd Zuhan Mohd Najib, Razali TP Chemical technology The wastewater of the aquaculture industry contains harmful pollutants that have harmful effects on aquatic life and population. The main concern is the high values of biological oxygen demand (BOD), chemical oxygen demand (COD), and ammoniacal nitrogen in wastewater, which do not comply with the Environmental Quality (Industrial Effluents) Regulations 2009 under the Environmental Quality Act (1974), the Department of Environment (DOE), Malaysia. This study aims to evaluate the efficiency of natural and commercial wastewater treatment of aquaculture wastewater. Two natural reagents (activated carbon (AC) and MNRg-Treat powder) and a biological coagulant (MNRg-Treat liquid) were used to treat aquaculture wastewater samples. Nine beakers were used in this treatment, and 1.5 L of wastewater samples from the shrimp, tilapia, and patin ponds were poured into three beakers. After that, 7.5% by weight of each reagent was added to 1.5 L of wastewater for each sample and left for three days without mechanical assistance. Then, five parameters were analyzed for the samples in each beaker: pH, BOD, COD, dissolved oxygen (DO), and ammoniacal nitrogen. The results showed that AC is the best material to reduce ammoniacal nitrogen. The ammoniacal nitrogen level of the tilapia pond reduced by 58.82% and the patin pond reduced by 30.77% using AC, followed by 17.64% reduction using MNRg-Treat liquid for the tilapia pond. Meanwhile, MNRg-Treat powder recorded 5.88% reduction for the tilapia pond. The obtained results showed that the treatment agents demonstrated their best performance at 7.5 wt. %. 2021 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/30978/1/18.%20Remediation%20of%20aquaculture%20effluents%20using%20physical%20treatment.pdf pdf en http://umpir.ump.edu.my/id/eprint/30978/2/18.1%20Remediation%20of%20aquaculture%20effluents%20using%20physical%20treatment.pdf M. Taqiuddin, Karia and A. Hazim, Haziq and Najmuddin, Mohd Ramli and Mohd Khairul Nizam, Mohd Zuhan and Mohd Najib, Razali (2021) Remediation of aquaculture effluents using physical treatment. In: International Symposium of Reaction Engineering, Catalysis & Sustainable Energy , 6 Apr. 2021 , Virtual Conference. pp. 1-8.. (Unpublished) (Unpublished)
spellingShingle TP Chemical technology
M. Taqiuddin, Karia
A. Hazim, Haziq
Najmuddin, Mohd Ramli
Mohd Khairul Nizam, Mohd Zuhan
Mohd Najib, Razali
Remediation of aquaculture effluents using physical treatment
title Remediation of aquaculture effluents using physical treatment
title_full Remediation of aquaculture effluents using physical treatment
title_fullStr Remediation of aquaculture effluents using physical treatment
title_full_unstemmed Remediation of aquaculture effluents using physical treatment
title_short Remediation of aquaculture effluents using physical treatment
title_sort remediation of aquaculture effluents using physical treatment
topic TP Chemical technology
url http://umpir.ump.edu.my/id/eprint/30978/
http://umpir.ump.edu.my/id/eprint/30978/1/18.%20Remediation%20of%20aquaculture%20effluents%20using%20physical%20treatment.pdf
http://umpir.ump.edu.my/id/eprint/30978/2/18.1%20Remediation%20of%20aquaculture%20effluents%20using%20physical%20treatment.pdf