Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection

The performance of Thermo-Electric Generator (TEG) is negatively affected by heat sink lack of design. The heat pipe heat sink (HP-HS) has the best performance compared to other conventional cooling systems which uses TEG. In medium temperature range below 300 °C, HP-HS is the most appropriate heat...

Full description

Bibliographic Details
Main Authors: Elghool, Ali, F., Basrawi, Ibrahim, Thamir K., Ibrahim, Hassan, M., Ishak, Mohd Hazwan, Yusof, Bagaber, Salem Abdullah
Format: Article
Language:English
Published: Elsevier 2020
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/29614/
http://umpir.ump.edu.my/id/eprint/29614/1/Multi-objective%20optimization%20to%20enhance%20the%20performance%20of%20thermo.pdf
_version_ 1848823320782307328
author Elghool, Ali
F., Basrawi
Ibrahim, Thamir K.
Ibrahim, Hassan
M., Ishak
Mohd Hazwan, Yusof
Bagaber, Salem Abdullah
author_facet Elghool, Ali
F., Basrawi
Ibrahim, Thamir K.
Ibrahim, Hassan
M., Ishak
Mohd Hazwan, Yusof
Bagaber, Salem Abdullah
author_sort Elghool, Ali
building UMP Institutional Repository
collection Online Access
description The performance of Thermo-Electric Generator (TEG) is negatively affected by heat sink lack of design. The heat pipe heat sink (HP-HS) has the best performance compared to other conventional cooling systems which uses TEG. In medium temperature range below 300 °C, HP-HS is the most appropriate heat exchanger of the TEG. However, the effect of some parameters of fin space, fin length, fin height, fin materials and optimum geometry of the cold side of the TEG HP-HS under forced convection (FC) has not been fully studied. The objective of this paper is to conduct an analytical and statistical study on these parameters effect on the performance of the TEG. In addition, this paper determines the optimum geometry of HP-HS and materials of aluminum (AL) and copper (CO) at 250 °C of heat source temperatures. Central composite design model (CCD) has been used to design the experiments using response surface methodology (RSM). The multi-objective optimization using RSM is applied to determine the optimum geometry of HP-HS in terms of maximising the TEG power output (P), TEG efficiency (η), and minimising HP-HS cost ($). Compared with the literature, the results showed an improvement in TEG performance. The maximum P and η after optimization were 9.6 W and 3.3%, respectively. The percentage difference of TEG efficiency (η) compared with best previous results were, 18.78%. In addition, the CO HP-HS was found to be preferred over AL, because of its lower $/P, at 7.57 USD/W, as compared to AL, at 8.74 USD. Finally, this study shows an improvement in HP-HS cost; a reduction of 29% was achieved compared with the estimated HP-HS cost in literature.
first_indexed 2025-11-15T02:55:16Z
format Article
id ump-29614
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T02:55:16Z
publishDate 2020
publisher Elsevier
recordtype eprints
repository_type Digital Repository
spelling ump-296142020-11-20T01:17:27Z http://umpir.ump.edu.my/id/eprint/29614/ Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection Elghool, Ali F., Basrawi Ibrahim, Thamir K. Ibrahim, Hassan M., Ishak Mohd Hazwan, Yusof Bagaber, Salem Abdullah TJ Mechanical engineering and machinery The performance of Thermo-Electric Generator (TEG) is negatively affected by heat sink lack of design. The heat pipe heat sink (HP-HS) has the best performance compared to other conventional cooling systems which uses TEG. In medium temperature range below 300 °C, HP-HS is the most appropriate heat exchanger of the TEG. However, the effect of some parameters of fin space, fin length, fin height, fin materials and optimum geometry of the cold side of the TEG HP-HS under forced convection (FC) has not been fully studied. The objective of this paper is to conduct an analytical and statistical study on these parameters effect on the performance of the TEG. In addition, this paper determines the optimum geometry of HP-HS and materials of aluminum (AL) and copper (CO) at 250 °C of heat source temperatures. Central composite design model (CCD) has been used to design the experiments using response surface methodology (RSM). The multi-objective optimization using RSM is applied to determine the optimum geometry of HP-HS in terms of maximising the TEG power output (P), TEG efficiency (η), and minimising HP-HS cost ($). Compared with the literature, the results showed an improvement in TEG performance. The maximum P and η after optimization were 9.6 W and 3.3%, respectively. The percentage difference of TEG efficiency (η) compared with best previous results were, 18.78%. In addition, the CO HP-HS was found to be preferred over AL, because of its lower $/P, at 7.57 USD/W, as compared to AL, at 8.74 USD. Finally, this study shows an improvement in HP-HS cost; a reduction of 29% was achieved compared with the estimated HP-HS cost in literature. Elsevier 2020-10-01 Article PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/29614/1/Multi-objective%20optimization%20to%20enhance%20the%20performance%20of%20thermo.pdf Elghool, Ali and F., Basrawi and Ibrahim, Thamir K. and Ibrahim, Hassan and M., Ishak and Mohd Hazwan, Yusof and Bagaber, Salem Abdullah (2020) Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection. Energy, 208 (118270). pp. 1-21. ISSN 0360-5442 (Print), 1873-6785 (Online). (Published) https://doi.org/10.1016/j.energy.2020.118270 https://doi.org/10.1016/j.energy.2020.118270
spellingShingle TJ Mechanical engineering and machinery
Elghool, Ali
F., Basrawi
Ibrahim, Thamir K.
Ibrahim, Hassan
M., Ishak
Mohd Hazwan, Yusof
Bagaber, Salem Abdullah
Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection
title Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection
title_full Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection
title_fullStr Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection
title_full_unstemmed Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection
title_short Multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection
title_sort multi-objective optimization to enhance the performance of thermo-electric generator combined with heat pipe-heat sink under forced convection
topic TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/29614/
http://umpir.ump.edu.my/id/eprint/29614/
http://umpir.ump.edu.my/id/eprint/29614/
http://umpir.ump.edu.my/id/eprint/29614/1/Multi-objective%20optimization%20to%20enhance%20the%20performance%20of%20thermo.pdf