Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults

A system can be disturbed in terms of stability when connected to a number of loads at the distribution ends or when subjected to faults. To reverse such systems to a stable state, FACTS devices such as static synchronous compensator (STATCOM) are used. In this paper, a cascaded multi-level voltage...

Full description

Bibliographic Details
Main Authors: Almelian, Mohamad Milood, Izzeldin, I. Mohd, Abu Zaharin, Ahmad, Omran, Mohamed Asghaiyer, Salem, Mohamed, Awang, Jusoh, Sutikno, Tole
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science (IAES) 2020
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/28472/
http://umpir.ump.edu.my/id/eprint/28472/1/Enhancement%20of%20cascaded%20multi-level%20VSC%20STATCOM%20performance.pdf
_version_ 1848823062604021760
author Almelian, Mohamad Milood
Izzeldin, I. Mohd
Abu Zaharin, Ahmad
Omran, Mohamed Asghaiyer
Salem, Mohamed
Awang, Jusoh
Sutikno, Tole
author_facet Almelian, Mohamad Milood
Izzeldin, I. Mohd
Abu Zaharin, Ahmad
Omran, Mohamed Asghaiyer
Salem, Mohamed
Awang, Jusoh
Sutikno, Tole
author_sort Almelian, Mohamad Milood
building UMP Institutional Repository
collection Online Access
description A system can be disturbed in terms of stability when connected to a number of loads at the distribution ends or when subjected to faults. To reverse such systems to a stable state, FACTS devices such as static synchronous compensator (STATCOM) are used. In this paper, a cascaded multi-level voltage source converter (VSC) STATCOM was designed and implemented with a novel space vector pulse width modulation (SVPWM) scheme. Artificial neural network (ANN) controller was used instead of instead of Proportional-Integral (PI) controller in the proposed scheme to improve the response time (RT) and performance of STATCOM in terms of power factor (PF) and voltage amplitude during periods of voltage sag. During the implementation, two fault sources (single-line-to-ground (SLG) and line-to- line (LL) faults) were used to create voltage sag. STATCOM was subjected to performance evaluation in the presence of these disturbances via MATLAB simulation in IEEE 3-bus system. The outcome of the simulation studies showed the ANN controller to perform better than PI as it was able to rapidly recover voltage value (<1 cycle) with unity PF.
first_indexed 2025-11-15T02:51:10Z
format Article
id ump-28472
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T02:51:10Z
publishDate 2020
publisher Institute of Advanced Engineering and Science (IAES)
recordtype eprints
repository_type Digital Repository
spelling ump-284722020-11-24T05:01:17Z http://umpir.ump.edu.my/id/eprint/28472/ Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults Almelian, Mohamad Milood Izzeldin, I. Mohd Abu Zaharin, Ahmad Omran, Mohamed Asghaiyer Salem, Mohamed Awang, Jusoh Sutikno, Tole TK Electrical engineering. Electronics Nuclear engineering A system can be disturbed in terms of stability when connected to a number of loads at the distribution ends or when subjected to faults. To reverse such systems to a stable state, FACTS devices such as static synchronous compensator (STATCOM) are used. In this paper, a cascaded multi-level voltage source converter (VSC) STATCOM was designed and implemented with a novel space vector pulse width modulation (SVPWM) scheme. Artificial neural network (ANN) controller was used instead of instead of Proportional-Integral (PI) controller in the proposed scheme to improve the response time (RT) and performance of STATCOM in terms of power factor (PF) and voltage amplitude during periods of voltage sag. During the implementation, two fault sources (single-line-to-ground (SLG) and line-to- line (LL) faults) were used to create voltage sag. STATCOM was subjected to performance evaluation in the presence of these disturbances via MATLAB simulation in IEEE 3-bus system. The outcome of the simulation studies showed the ANN controller to perform better than PI as it was able to rapidly recover voltage value (<1 cycle) with unity PF. Institute of Advanced Engineering and Science (IAES) 2020-06 Article PeerReviewed pdf en cc_by_sa_4 http://umpir.ump.edu.my/id/eprint/28472/1/Enhancement%20of%20cascaded%20multi-level%20VSC%20STATCOM%20performance.pdf Almelian, Mohamad Milood and Izzeldin, I. Mohd and Abu Zaharin, Ahmad and Omran, Mohamed Asghaiyer and Salem, Mohamed and Awang, Jusoh and Sutikno, Tole (2020) Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults. International Journal of Power Electronics and Drive System (IJPEDS), 11 (2). pp. 895-906. ISSN 2088-8694 (print); 2088-8694 (online). (Published) http://doi.org/10.11591/ijpeds.v11.i2.pp895-906 http://doi.org/10.11591/ijpeds.v11.i2.pp895-906
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Almelian, Mohamad Milood
Izzeldin, I. Mohd
Abu Zaharin, Ahmad
Omran, Mohamed Asghaiyer
Salem, Mohamed
Awang, Jusoh
Sutikno, Tole
Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults
title Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults
title_full Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults
title_fullStr Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults
title_full_unstemmed Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults
title_short Enhancement of cascaded multi-level VSC STATCOM performance using ANN in the presence of faults
title_sort enhancement of cascaded multi-level vsc statcom performance using ann in the presence of faults