Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design

Pedicle screws are widely used for the treatment of spinal instability by spine fusion. This treatment can be performed at any level in the spine (cervical, thoracic or lumbar) and prevents any movement between the fused vertebrae. However screw loosening is a major problem of spine fusion, contribu...

Full description

Bibliographic Details
Main Authors: Rosdi, Daud, A., Asyraf, Mas Ayu, Hassan, A., Shah
Format: Conference or Workshop Item
Language:English
English
Published: Universiti Malaysia Pahang 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/27843/
http://umpir.ump.edu.my/id/eprint/27843/1/115.%20Investigation%20on%20pullout%20strength%20between%20different%20design.pdf
http://umpir.ump.edu.my/id/eprint/27843/2/115.1%20Investigation%20on%20pullout%20strength%20between%20different%20design.pdf
_version_ 1848822899645874176
author Rosdi, Daud
A., Asyraf
Mas Ayu, Hassan
A., Shah
author_facet Rosdi, Daud
A., Asyraf
Mas Ayu, Hassan
A., Shah
author_sort Rosdi, Daud
building UMP Institutional Repository
collection Online Access
description Pedicle screws are widely used for the treatment of spinal instability by spine fusion. This treatment can be performed at any level in the spine (cervical, thoracic or lumbar) and prevents any movement between the fused vertebrae. However screw loosening is a major problem of spine fusion, contributing to delayed patient recovery. This appears to be a minor problem for fixation and fusion of healthy, non-osteoporotic bone. Screw loosening happen when insertion torque and angle that are not suitable for pedicle screw which affected the screw pullout strength. Based on optimum torque and angle in finite element analysis, loosening of screw in spine fusion can be minimized by increasing the screw pullout strength. The highest of pull out strength can minor the loosening of screw. Four insertion angle of pedicle screw were used which are 0°, 10°, 20° and 30°. Besides that, effect of insertion torque on pullout strength can be seen on Equivalent von Mises stress value when applied three value of moment to pedicle screw-bone with constant of insertion angle. The lowest stress for pedicle screw can give a better fixation with bone and thus can increase the pullout strength. We found that the insertion angle 10° give higher pullout strength of pedicle screw-synthetic bone which indirectly will minimizing the effect of the screw loosening from bone. Besides that, insertion torque with 1200 Nm give a lower Equivalent von Mises stress which it cause the less effect on fixation between screw and bone and thus has potential in minimizing the loosening to pedicle screw.
first_indexed 2025-11-15T02:48:34Z
format Conference or Workshop Item
id ump-27843
institution Universiti Malaysia Pahang
institution_category Local University
language English
English
last_indexed 2025-11-15T02:48:34Z
publishDate 2019
publisher Universiti Malaysia Pahang
recordtype eprints
repository_type Digital Repository
spelling ump-278432021-01-18T04:22:12Z http://umpir.ump.edu.my/id/eprint/27843/ Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design Rosdi, Daud A., Asyraf Mas Ayu, Hassan A., Shah TJ Mechanical engineering and machinery Pedicle screws are widely used for the treatment of spinal instability by spine fusion. This treatment can be performed at any level in the spine (cervical, thoracic or lumbar) and prevents any movement between the fused vertebrae. However screw loosening is a major problem of spine fusion, contributing to delayed patient recovery. This appears to be a minor problem for fixation and fusion of healthy, non-osteoporotic bone. Screw loosening happen when insertion torque and angle that are not suitable for pedicle screw which affected the screw pullout strength. Based on optimum torque and angle in finite element analysis, loosening of screw in spine fusion can be minimized by increasing the screw pullout strength. The highest of pull out strength can minor the loosening of screw. Four insertion angle of pedicle screw were used which are 0°, 10°, 20° and 30°. Besides that, effect of insertion torque on pullout strength can be seen on Equivalent von Mises stress value when applied three value of moment to pedicle screw-bone with constant of insertion angle. The lowest stress for pedicle screw can give a better fixation with bone and thus can increase the pullout strength. We found that the insertion angle 10° give higher pullout strength of pedicle screw-synthetic bone which indirectly will minimizing the effect of the screw loosening from bone. Besides that, insertion torque with 1200 Nm give a lower Equivalent von Mises stress which it cause the less effect on fixation between screw and bone and thus has potential in minimizing the loosening to pedicle screw. Universiti Malaysia Pahang 2019 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/27843/1/115.%20Investigation%20on%20pullout%20strength%20between%20different%20design.pdf pdf en http://umpir.ump.edu.my/id/eprint/27843/2/115.1%20Investigation%20on%20pullout%20strength%20between%20different%20design.pdf Rosdi, Daud and A., Asyraf and Mas Ayu, Hassan and A., Shah (2019) Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design. In: 4th International Conference on Advances in Manufacturing and Materials Engineering 2019 , 29 Oct.- 1 Nov. 2019 , Putrajaya International Convention Centre (PICC), Putrajaya. pp. 1-5.. (Unpublished) (Unpublished)
spellingShingle TJ Mechanical engineering and machinery
Rosdi, Daud
A., Asyraf
Mas Ayu, Hassan
A., Shah
Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design
title Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design
title_full Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design
title_fullStr Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design
title_full_unstemmed Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design
title_short Investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design
title_sort investigation on pullout strength between different design of cannulated pedicle screw and osteoporosis bones to obtain an optimum design
topic TJ Mechanical engineering and machinery
url http://umpir.ump.edu.my/id/eprint/27843/
http://umpir.ump.edu.my/id/eprint/27843/1/115.%20Investigation%20on%20pullout%20strength%20between%20different%20design.pdf
http://umpir.ump.edu.my/id/eprint/27843/2/115.1%20Investigation%20on%20pullout%20strength%20between%20different%20design.pdf