Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application

Electrical resistance tomography is used to reconstruct the image of the objects within the medium of interest based on electrical conductivity distribution. Besides, the ordinary technique of ERT applied invasive technique and causing corrosion to the electrodes because of the contact between the e...

Full description

Bibliographic Details
Main Authors: Yasmin, Abdul Wahab, Mahanum, Muhamad Sakri, Mohd Anwar, Zawawi, Muhammad Sharfi, Najib, Normaniha, Abd Ghani
Format: Conference or Workshop Item
Language:English
English
Published: Springer Singapore 2019
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/27018/
http://umpir.ump.edu.my/id/eprint/27018/1/108.%20Experimental%20study%20of%20optimization%20of%20electrode%20dimension.pdf
http://umpir.ump.edu.my/id/eprint/27018/2/108.1%20Experimental%20study%20of%20optimization%20of%20electrode%20dimension.pdf
_version_ 1848822684355395584
author Yasmin, Abdul Wahab
Mahanum, Muhamad Sakri
Mohd Anwar, Zawawi
Muhammad Sharfi, Najib
Normaniha, Abd Ghani
author_facet Yasmin, Abdul Wahab
Mahanum, Muhamad Sakri
Mohd Anwar, Zawawi
Muhammad Sharfi, Najib
Normaniha, Abd Ghani
author_sort Yasmin, Abdul Wahab
building UMP Institutional Repository
collection Online Access
description Electrical resistance tomography is used to reconstruct the image of the objects within the medium of interest based on electrical conductivity distribution. Besides, the ordinary technique of ERT applied invasive technique and causing corrosion to the electrodes because of the contact between the electrode and the conductive liquid. Therefore, the ERT system proposed in this work is to investigate the optimize dimension of the electrode in ERT using experimental approach for non-invasive measurement. In this project, four electrodes are used as transmitter and receiver. All the electrodes are arranged side by side around the pipe. In this process, only one electrode is used as a transmitter and the rest as a receiving sensor. When water is inserted in the pipe, the output of the voltage will be compressed and recorded. Nine different dimensions are investigated and it produces a different voltage output. Therefore, the appropriate electrode dimension must be determined as it also affects the conductivity of the conducting medium. In addition, the appropriate electrode dimension which is 35.34 mm (width) x 250 mm (height) was chosen as the optimize dimension from the experiment to improve the performance of the existing system.
first_indexed 2025-11-15T02:45:09Z
format Conference or Workshop Item
id ump-27018
institution Universiti Malaysia Pahang
institution_category Local University
language English
English
last_indexed 2025-11-15T02:45:09Z
publishDate 2019
publisher Springer Singapore
recordtype eprints
repository_type Digital Repository
spelling ump-270182021-08-20T08:13:22Z http://umpir.ump.edu.my/id/eprint/27018/ Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application Yasmin, Abdul Wahab Mahanum, Muhamad Sakri Mohd Anwar, Zawawi Muhammad Sharfi, Najib Normaniha, Abd Ghani TK Electrical engineering. Electronics Nuclear engineering Electrical resistance tomography is used to reconstruct the image of the objects within the medium of interest based on electrical conductivity distribution. Besides, the ordinary technique of ERT applied invasive technique and causing corrosion to the electrodes because of the contact between the electrode and the conductive liquid. Therefore, the ERT system proposed in this work is to investigate the optimize dimension of the electrode in ERT using experimental approach for non-invasive measurement. In this project, four electrodes are used as transmitter and receiver. All the electrodes are arranged side by side around the pipe. In this process, only one electrode is used as a transmitter and the rest as a receiving sensor. When water is inserted in the pipe, the output of the voltage will be compressed and recorded. Nine different dimensions are investigated and it produces a different voltage output. Therefore, the appropriate electrode dimension must be determined as it also affects the conductivity of the conducting medium. In addition, the appropriate electrode dimension which is 35.34 mm (width) x 250 mm (height) was chosen as the optimize dimension from the experiment to improve the performance of the existing system. Springer Singapore 2019 Conference or Workshop Item PeerReviewed pdf en http://umpir.ump.edu.my/id/eprint/27018/1/108.%20Experimental%20study%20of%20optimization%20of%20electrode%20dimension.pdf pdf en http://umpir.ump.edu.my/id/eprint/27018/2/108.1%20Experimental%20study%20of%20optimization%20of%20electrode%20dimension.pdf Yasmin, Abdul Wahab and Mahanum, Muhamad Sakri and Mohd Anwar, Zawawi and Muhammad Sharfi, Najib and Normaniha, Abd Ghani (2019) Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application. In: InECCE2019: Proceedings of the 5th International Conference on Electrical, Control & Computer Engineering , 29th July 2019 , Kuantan, Pahang, Malaysia. pp. 37-46., 632. ISBN 978-981-15-2316-8 (Published) https://doi.org/10.1007/978-981-15-2317-5_4
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Yasmin, Abdul Wahab
Mahanum, Muhamad Sakri
Mohd Anwar, Zawawi
Muhammad Sharfi, Najib
Normaniha, Abd Ghani
Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application
title Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application
title_full Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application
title_fullStr Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application
title_full_unstemmed Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application
title_short Experimental Study of Optimization of Electrode Dimension for Non-invasive Electrical Resistance Tomography Application
title_sort experimental study of optimization of electrode dimension for non-invasive electrical resistance tomography application
topic TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/27018/
http://umpir.ump.edu.my/id/eprint/27018/
http://umpir.ump.edu.my/id/eprint/27018/1/108.%20Experimental%20study%20of%20optimization%20of%20electrode%20dimension.pdf
http://umpir.ump.edu.my/id/eprint/27018/2/108.1%20Experimental%20study%20of%20optimization%20of%20electrode%20dimension.pdf