Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang

The knowledge of groundwater resource in Pahang is low compared to the other state because Pahang received a large amount of rainfall each year which are between 2032 mm to 2540 mm. Consequently, the demand for groundwater is very low. Despite this, development of groundwater needs to be done to sup...

Full description

Bibliographic Details
Main Author: Mohd Salamuddin, Ab Salam @ Nawi
Format: Undergraduates Project Papers
Language:English
Published: 2010
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/2537/
http://umpir.ump.edu.my/id/eprint/2537/1/MOHD_SALAMUDDIN_BIN_AB_SALAM__NAWI.PDF
_version_ 1848817079120035840
author Mohd Salamuddin, Ab Salam @ Nawi
author_facet Mohd Salamuddin, Ab Salam @ Nawi
author_sort Mohd Salamuddin, Ab Salam @ Nawi
building UMP Institutional Repository
collection Online Access
description The knowledge of groundwater resource in Pahang is low compared to the other state because Pahang received a large amount of rainfall each year which are between 2032 mm to 2540 mm. Consequently, the demand for groundwater is very low. Despite this, development of groundwater needs to be done to supply water to the public demand and to avoid the lack of water in the dry season. Aware of this fact, two areas in Pahang which are Kuantan and Bentong were selected as study areas. The study involved analysis of data pumping test collected from Mineralogy and Geoscience Department Pahang. The type of aquifer of both places is unconfined aquifer. In this study, Mineralogy and Geoscience Department have provided sufficient data for the analysis of this aquifer. The data collected are constant rate pumping test data, recovery pumping test data and step pumping test data. The study has found that, both of study areas have different geology which Kuantan is sand and gravel while Bentong is rock. Hydraulic conductivity, K for Kuantan is in region 700m/day to 2500m/day and Bentong is in reion im/day to 3 rn/day. Tranmissivity, T of aquifer in Kuantan is in region 3000 in /day to 9000 m 2 /day and Bentong is in region 4 m 2 /day to 12m 2 /day. Besides that, the well efficiency, E in Kuantan shows a high efficiency than Bentong which the value is 89% and 47.42% respectively. Furthermore. Average iron content in groundwater in Kuantan is 5 ppm exceeding the maximum iron content as stated in Ministry of Health Malaysia Standards. However iron content in this well can be reduced by river infiltration through the well. While water quality in Bentong shows the value for each element is acceptable in Ministry Of Health Malaysia. From this study, the results indicated that Kuantan area has a potential for groundwater development in Pahang compared to Bentong area.
first_indexed 2025-11-15T01:16:04Z
format Undergraduates Project Papers
id ump-2537
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T01:16:04Z
publishDate 2010
recordtype eprints
repository_type Digital Repository
spelling ump-25372021-06-24T07:37:22Z http://umpir.ump.edu.my/id/eprint/2537/ Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang Mohd Salamuddin, Ab Salam @ Nawi TD Environmental technology. Sanitary engineering The knowledge of groundwater resource in Pahang is low compared to the other state because Pahang received a large amount of rainfall each year which are between 2032 mm to 2540 mm. Consequently, the demand for groundwater is very low. Despite this, development of groundwater needs to be done to supply water to the public demand and to avoid the lack of water in the dry season. Aware of this fact, two areas in Pahang which are Kuantan and Bentong were selected as study areas. The study involved analysis of data pumping test collected from Mineralogy and Geoscience Department Pahang. The type of aquifer of both places is unconfined aquifer. In this study, Mineralogy and Geoscience Department have provided sufficient data for the analysis of this aquifer. The data collected are constant rate pumping test data, recovery pumping test data and step pumping test data. The study has found that, both of study areas have different geology which Kuantan is sand and gravel while Bentong is rock. Hydraulic conductivity, K for Kuantan is in region 700m/day to 2500m/day and Bentong is in reion im/day to 3 rn/day. Tranmissivity, T of aquifer in Kuantan is in region 3000 in /day to 9000 m 2 /day and Bentong is in region 4 m 2 /day to 12m 2 /day. Besides that, the well efficiency, E in Kuantan shows a high efficiency than Bentong which the value is 89% and 47.42% respectively. Furthermore. Average iron content in groundwater in Kuantan is 5 ppm exceeding the maximum iron content as stated in Ministry of Health Malaysia Standards. However iron content in this well can be reduced by river infiltration through the well. While water quality in Bentong shows the value for each element is acceptable in Ministry Of Health Malaysia. From this study, the results indicated that Kuantan area has a potential for groundwater development in Pahang compared to Bentong area. 2010-11 Undergraduates Project Papers NonPeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/2537/1/MOHD_SALAMUDDIN_BIN_AB_SALAM__NAWI.PDF Mohd Salamuddin, Ab Salam @ Nawi (2010) Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang. Faculty of Civil Engineering & Earth Resources , Universiti Malaysia Pahang .
spellingShingle TD Environmental technology. Sanitary engineering
Mohd Salamuddin, Ab Salam @ Nawi
Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang
title Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang
title_full Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang
title_fullStr Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang
title_full_unstemmed Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang
title_short Study on groundwater potential as alternative water supply in Kuantan and Bentong, Pahang
title_sort study on groundwater potential as alternative water supply in kuantan and bentong, pahang
topic TD Environmental technology. Sanitary engineering
url http://umpir.ump.edu.my/id/eprint/2537/
http://umpir.ump.edu.my/id/eprint/2537/1/MOHD_SALAMUDDIN_BIN_AB_SALAM__NAWI.PDF