Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability

According to modern grid codes (GCs), high penetration of photovoltaic power plants (PVPPs) to the utility grid requires a reliable PV generation system by achieving fault ride-through (FRT) requirements. In order to meet these requirements, there are two major issues that should be addressed to kee...

Full description

Bibliographic Details
Main Authors: Al-Shetwi, Ali Q., Muhamad Zahim, Sujod
Format: Article
Language:English
Published: The American Society of Mechanical Engineers 2017
Subjects:
Online Access:http://umpir.ump.edu.my/id/eprint/20500/
http://umpir.ump.edu.my/id/eprint/20500/1/fkee-2017-shetwi-Modeling%20and%20Control%20of%20Grid-Connected%20Photovoltaic1.pdf
_version_ 1848821118568235008
author Al-Shetwi, Ali Q.
Muhamad Zahim, Sujod
author_facet Al-Shetwi, Ali Q.
Muhamad Zahim, Sujod
author_sort Al-Shetwi, Ali Q.
building UMP Institutional Repository
collection Online Access
description According to modern grid codes (GCs), high penetration of photovoltaic power plants (PVPPs) to the utility grid requires a reliable PV generation system by achieving fault ride-through (FRT) requirements. In order to meet these requirements, there are two major issues that should be addressed to keep the inverter connected during grid fault. The two issues are the ac over-current and dc-link over-voltage that may cause disconnection or damage to the grid inverter. In this paper, the control of single-stage PVPP inverters is developed to address these issues and enhance FRT capability. The proposed control scheme introduces the dc brake chopper circuit and current limiter to protect the inverter and ride through the fault smoothly with no perceptible overcompensation. A 1.5 MW PVPP connected into the Malaysian grid and modeled in simulink is utilized to explain the proposed control scheme. The simulation results presented demonstrate the effectiveness of the overall proposed control strategy to ride through different types of faults and to help to ensure the safety of the system equipment
first_indexed 2025-11-15T02:20:16Z
format Article
id ump-20500
institution Universiti Malaysia Pahang
institution_category Local University
language English
last_indexed 2025-11-15T02:20:16Z
publishDate 2017
publisher The American Society of Mechanical Engineers
recordtype eprints
repository_type Digital Repository
spelling ump-205002019-10-18T02:39:31Z http://umpir.ump.edu.my/id/eprint/20500/ Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability Al-Shetwi, Ali Q. Muhamad Zahim, Sujod TK Electrical engineering. Electronics Nuclear engineering According to modern grid codes (GCs), high penetration of photovoltaic power plants (PVPPs) to the utility grid requires a reliable PV generation system by achieving fault ride-through (FRT) requirements. In order to meet these requirements, there are two major issues that should be addressed to keep the inverter connected during grid fault. The two issues are the ac over-current and dc-link over-voltage that may cause disconnection or damage to the grid inverter. In this paper, the control of single-stage PVPP inverters is developed to address these issues and enhance FRT capability. The proposed control scheme introduces the dc brake chopper circuit and current limiter to protect the inverter and ride through the fault smoothly with no perceptible overcompensation. A 1.5 MW PVPP connected into the Malaysian grid and modeled in simulink is utilized to explain the proposed control scheme. The simulation results presented demonstrate the effectiveness of the overall proposed control strategy to ride through different types of faults and to help to ensure the safety of the system equipment The American Society of Mechanical Engineers 2017 Article PeerReviewed application/pdf en http://umpir.ump.edu.my/id/eprint/20500/1/fkee-2017-shetwi-Modeling%20and%20Control%20of%20Grid-Connected%20Photovoltaic1.pdf Al-Shetwi, Ali Q. and Muhamad Zahim, Sujod (2017) Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability. Journal of Solar Energy Engineering, 140 (2). pp. 1-8. ISSN 0199-6231 (print); 1528-8986 (online). (Published) https://doi.org/10.1115/1.4038591 doi: 10.1115/1.4038591
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Al-Shetwi, Ali Q.
Muhamad Zahim, Sujod
Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability
title Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability
title_full Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability
title_fullStr Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability
title_full_unstemmed Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability
title_short Modeling and Control of Grid-Connected Photovoltaic Power Plant With Fault Ride-Through Capability
title_sort modeling and control of grid-connected photovoltaic power plant with fault ride-through capability
topic TK Electrical engineering. Electronics Nuclear engineering
url http://umpir.ump.edu.my/id/eprint/20500/
http://umpir.ump.edu.my/id/eprint/20500/
http://umpir.ump.edu.my/id/eprint/20500/
http://umpir.ump.edu.my/id/eprint/20500/1/fkee-2017-shetwi-Modeling%20and%20Control%20of%20Grid-Connected%20Photovoltaic1.pdf